Panasonic’s DS-P Series Polarized Power Relays are characterized by their high sensitivity, which allows for 190 mW and breakdown voltage, which has been raised by keeping the coil and contacts separate. Three types of contact arrangements are offered for this series, 1a, 2a, and 1a1b. In addition, each is available in standard and reversed polarity types. The DS-P Series Relays are ideal for various applications, including office and industrial electronic devices, terminal devices for information processing equipment, measuring instruments, and more.
Features & Benefits of DS-P Series
Compact Size Width (11mm) x Length (20.2mm) x Height (10.5mm) with High Contact Rating
High Switching Capability: 1a, 8 A 250 V AC; 2a and 1a1b, 5 A 250 V AC
High Sensitivity and Breakdown Voltage
Sealed Construction Allows Automatic Washing
UL, CSA, and TÜV Compliant
Latching Types and Sockets Available
PC Board Sockets Available For Easy Replacement of Relay For Simple Maintenance
Industries for DS-P Series
Industrial
Test And Measurement
Robotics
Commercial
Applications for DS-P Series
Electric Power Equipment
Measuring Instruments
Industrial Machines
Office Automation Equipment
DS-P Series Relays
Part number list
Results 54
Models table for series DS-P Series Relays
Part No.
Datasheet
Operating Function
Rated Coil Voltage
Contact Arrangement
Protective Construction
Terminal Type
Accessories
Operate Voltage (@20oC)
Release Voltage (at20°C)
Rated Operating Current [±10%] (at 20°C)
Resistance [±10%] (at 20°C)
Rated Operating Power
Max. Allowable Voltage (at 20°C 68°F)
Contact Resistance (Initial)
Contact Material
Contact Rating (Resistive Load)
Max. Switching Power (Resistive Load)
Max. Switching Voltage
Max. Switching Current
Min. Switching Load (Reference Value)
Insulation Resistance (Initial)
Dielectric Strength (Initial): Between Open Contacts
Dielectric Strength (Initial): Between Contact and Coil
Surge Withstand Voltage (Initial): Between Contact and Coil
Operate Time (Initial) (At 20oC)
Release Time (Initial) (at 20°C)
Hock Resistance (Functional)
Dielectric Strength (Initial): Between Contact Sets
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3.5 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +60℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 4.5 g
[switching frequency: 20 times/min] Min. 100x103 ope. 8 A 250 V AC Min. 100x103 ope. 5 A 30 V DC
Max. 80% V of rated coil voltage (Initial)
Max. 80% V of rated coil voltage (Initial)
Max. 10 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
50
500
Single
New Product Information Download
Stay Up-To-Date On The Latest Product Details
Find the latest new product details here, with a convenient PDF product summary document. Quickly access and download the latest product information for the new DS-P Series Polarized Power Relays, including product specifications, features, benefits, industries and applications, software, block diagrams, and technical characteristics.