The HE-S Series is a compact Power Relay with low operating power and high-capacity switching. This Relay features contacts with long electrical life and a high-capacity resistive switching load rating of 35A at 277VAC for 50,000 cycles.

This Relay also features a mirror contact structure (compliant with EN60947-4-1) which uses a 2 Form A coupled with a 1 Form B contact arrangement.
 
Features:

  • 35A @ 277VAC (50,000 Cycles N.O.)
  • 30 x 36 x 40 mm Case Size
  • 1,880 mW Nominal Operating Power/170mW Coil Holding Power
  • Large Contact Gap and Insulation Distance
  • Mirror Contact Mechanisms
  • RoHS/REACH Compliant

Benefits:

  • High-Capacity and Long Electrical Life
  • Takes up Less Board Space
  • Low Power Operation
  • Compliant with VDE126 and EN61810-1 Standards
  • 1 Form B Contact Can Be Used To Monitor the Condition of N.O Contacts for Weld Detection
  • Environmentally Friendly
Series image for HE-S Series Relays

HE-S Series Relays

Part number list

Results 20
Models table for series HE-S Series Relays
Part No.DatasheetElectrical Life TypeRated Coil VoltageContact ArrangementProtective ConstructionOperating Function Terminal TypeContact TypePacking Quantity; Inner Carton (Pcs.) Packing Quantity; Outer Carton (Pcs.)Operate Voltage (@20oC)Release Voltage (at20°C) Rated Operating Current [±10%] (at 20°C)Resistance [±10%] (at 20°C) Rated Operating Power Max. Allowable Voltage Contact ShapeContact Resistance (Initial)Contact MaterialContact Rating (Resistive Load)Max. Switching Power (Resistive Load) Max. Switching VoltageMax. Switching CurrentMin. Switching Load (Reference Value) Insulation Resistance (Initial)Hort Current (A Contact, Initial)Dielectric Strength (Initial): Between Open ContactsDielectric Strength (Initial): Between Contact SetsDielectric Strength (Initial): Between Contact and CoilDielectric Strength: Between Form A Contact and Form B ContactSurge Withstand Voltage (Initial): Between Contact and CoilCoil Holding VoltageOperate Time (Initial) (At 20oC)Release Time (Initial) (at 20°C) Hock Resistance (Functional)Hock Resistance (Destructive)Vibration Resistance (Functional) Vibration Resistance (Destructive)Mechanical LifeConditionsWeight (Typ.)Resistive LoadInductive LoadContact Gap
Standard type
6 V DC
2 Form A
Flux-resistant
Single side stable
PC board terminal
High capacity type
25
100
Max. 75% V of rated coil voltage (Initial)
Min. 5% V of rated coil voltage (Initial)
313 mA
19.1 Ω
1,880 mW
Holding: 170 mW
(at 55℃)
110% V of rated coil voltage
150% V of rated coil voltage (*4)
(*4): Total application time: Max. 24 hours
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Max. 3 mΩ (by voltage drop 6 V DC 40 A, reference value)
AgSnO2 type
40 A 277 V AC, 5 A 110 V DC
11,080 VA, 550 W
480 V AC, 110 V DC
40 A (Ambient temperature -40 to + 70°C)
35 A (Ambient temperature 70 to + 85°C)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Max. 1,000 A 1 ms, 3 times (Reference value)
Between open Form A contacts: 2,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact sets: 5,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact and coil: 5,000 Vrms for 1min (detection current: 10 mA)
5,000 Vrms for 1min (detection current: 10 mA)
10,000 V (Between Form A contact and coil)
30 to 110% V (at -40 to +55℃), 30 to 60% V (at +55 to +85℃)
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A)
Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s]
Min. 100x103 ope. 20 A 277 V AC
Min. 30x103 ope. 35 A 277 V AC
Min. 1,000 ope. 40 A 277 V AC
Min. 10x103 ope. 5 A 110 V DC
[switching frequency ON : OFF = 0.1 s : 10 s]
Min. 30x103 ope. 35 A 250 V AC (cosΦ = 0.8)
3.2 mm
Standard type
24 V DC
2 Form A 1 Form B
Flux-resistant
Single side stable
PC board terminal
High capacity type
25
100
Max. 75% V of rated coil voltage (Initial)
Min. 5% V of rated coil voltage (Initial)
78 mA
306.4 Ω
1,880 mW
Holding: 170 mW
(at 55℃)
110% V of rated coil voltage
150% V of rated coil voltage (*4)
(*4): Total application time: Max. 24 hours
Single
Form A contact: Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Form A contact: Max. 3 mΩ (by voltage drop 6 V DC 40 A, reference value)
Form B contact: Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Form A contact: AgSnO2 type
Form B contact: Au flashed AgNi type
Form A contact: 40 A 277 V AC, 5 A 110 V DC
Form B contact: 1 A 277 V AC, 1 A 30 V DC
Form A contact:11,080 VA
Form B contact:277 VA, 30 W
Form A contact: 480 V AC, 110 V DC
Form B contact: 277 V AC, 30 V DC
Form A contact:
40 A (Ambient temperature -40 to + 70°C)
35 A (Ambient temperature 70 to + 85°C)
Form B contact:
1 A
Form A contact: 100 mA 5 V DC
Form B contact: 10 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Max. 1,000 A 1 ms, 3 times (Reference value)
Between open Form A contacts: 2,000 Vrms for 1min (detection current: 10 mA)
Between open Form B contacts: 1,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact sets: 5,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact and coil: 5,000 Vrms for 1min (detection current: 10 mA)
Between Form B contact and coil: 2,000 Vrms for 1min (detection current: 10 mA)
5,000 Vrms for 1min (detection current: 10 mA)
10,000 V (Between Form A contact and coil)
2,500 V (Between Form B contact and coil)
30 to 110% V (at -40 to +55℃), 30 to 60% V (at +55 to +85℃)
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A)
Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s]
Form A contact:
Min. 100x103 ope. 20 A 277 V AC
Min. 30x103 ope. 35 A 277 V AC
Min. 1,000 ope. 40 A 277 V AC
Min. 10x103 ope. 5 A 110 V DC
Form B contact:
Min. 100x103 ope. 1 A 277 V AC
Min. 100x103 ope. 1 A 30 V DC
[switching frequency ON : OFF = 0.1 s : 10 s]
Form A contact: Min. 30x103 ope. 35 A 250 V AC (cosΦ = 0.8)
3.2 mm
Standard type
12 V DC
2 Form A
Flux-resistant
Single side stable
PC board terminal
High capacity type
25
100
Max. 75% V of rated coil voltage (Initial)
Min. 5% V of rated coil voltage (Initial)
157 mA
76.6 Ω
1,880 mW
Holding: 170 mW
(at 55℃)
110% V of rated coil voltage
150% V of rated coil voltage (*4)
(*4): Total application time: Max. 24 hours
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Max. 3 mΩ (by voltage drop 6 V DC 40 A, reference value)
AgSnO2 type
40 A 277 V AC, 5 A 110 V DC
11,080 VA, 550 W
480 V AC, 110 V DC
40 A (Ambient temperature -40 to + 70°C)
35 A (Ambient temperature 70 to + 85°C)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Max. 1,000 A 1 ms, 3 times (Reference value)
Between open Form A contacts: 2,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact sets: 5,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact and coil: 5,000 Vrms for 1min (detection current: 10 mA)
5,000 Vrms for 1min (detection current: 10 mA)
10,000 V (Between Form A contact and coil)
30 to 110% V (at -40 to +55℃), 30 to 60% V (at +55 to +85℃)
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A)
Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s]
Min. 100x103 ope. 20 A 277 V AC
Min. 30x103 ope. 35 A 277 V AC
Min. 1,000 ope. 40 A 277 V AC
Min. 10x103 ope. 5 A 110 V DC
[switching frequency ON : OFF = 0.1 s : 10 s]
Min. 30x103 ope. 35 A 250 V AC (cosΦ = 0.8)
3.2 mm
Long life type
48 V DC
2 Form A
Flux-resistant
Single side stable
PC board terminal
High capacity type
25
100
Max. 75% V of rated coil voltage (Initial)
Min. 5% V of rated coil voltage (Initial)
39 mA
1,225.5 Ω
1,880 mW
Holding: 170 mW
(at 55℃)
110% V of rated coil voltage
150% V of rated coil voltage (*4)
(*4): Total application time: Max. 24 hours
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Max. 3 mΩ (by voltage drop 6 V DC 40 A, reference value)
AgSnO2 type
40 A 277 V AC, 5 A 110 V DC
11,080 VA, 550 W
480 V AC, 110 V DC
40 A (Ambient temperature -40 to + 70°C)
35 A (Ambient temperature 70 to + 85°C)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Max. 1,000 A 1 ms, 3 times (Reference value)
Between open Form A contacts: 2,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact sets: 5,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact and coil: 5,000 Vrms for 1min (detection current: 10 mA)
5,000 Vrms for 1min (detection current: 10 mA)
10,000 V (Between Form A contact and coil)
30 to 110% V (at -40 to +55℃), 30 to 60% V (at +55 to +85℃)
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A)
Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s]
Min. 200x103 ope. 20 A 277 V AC
Min. 100x103 ope. 30 A 220 V AC
Min. 50x103 ope. 35 A 277 V AC
Min. 1,000 ope. 40 A 277 V AC
Min. 10x103 ope. 5 A 110 V DC
[switching frequency ON : OFF = 0.1 s : 10 s]
Min. 50x103 ope. 35 A 250 V AC (cosΦ = 0.8)
3.2 mm
Long life type
9 V DC
2 Form A
Flux-resistant
Single side stable
PC board terminal
High capacity type
25
100
Max. 75% V of rated coil voltage (Initial)
Min. 5% V of rated coil voltage (Initial)
209 mA
43.1 Ω
1,880 mW
Holding: 170 mW
(at 55℃)
110% V of rated coil voltage
150% V of rated coil voltage (*4)
(*4): Total application time: Max. 24 hours
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Max. 3 mΩ (by voltage drop 6 V DC 40 A, reference value)
AgSnO2 type
40 A 277 V AC, 5 A 110 V DC
11,080 VA, 550 W
480 V AC, 110 V DC
40 A (Ambient temperature -40 to + 70°C)
35 A (Ambient temperature 70 to + 85°C)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Max. 1,000 A 1 ms, 3 times (Reference value)
Between open Form A contacts: 2,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact sets: 5,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact and coil: 5,000 Vrms for 1min (detection current: 10 mA)
5,000 Vrms for 1min (detection current: 10 mA)
10,000 V (Between Form A contact and coil)
30 to 110% V (at -40 to +55℃), 30 to 60% V (at +55 to +85℃)
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A)
Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s]
Min. 200x103 ope. 20 A 277 V AC
Min. 100x103 ope. 30 A 220 V AC
Min. 50x103 ope. 35 A 277 V AC
Min. 1,000 ope. 40 A 277 V AC
Min. 10x103 ope. 5 A 110 V DC
[switching frequency ON : OFF = 0.1 s : 10 s]
Min. 50x103 ope. 35 A 250 V AC (cosΦ = 0.8)
3.2 mm
Long life type
12 V DC
2 Form A
Flux-resistant
Single side stable
PC board terminal
High capacity type
25
100
Max. 75% V of rated coil voltage (Initial)
Min. 5% V of rated coil voltage (Initial)
157 mA
76.6 Ω
1,880 mW
Holding: 170 mW
(at 55℃)
110% V of rated coil voltage
150% V of rated coil voltage (*4)
(*4): Total application time: Max. 24 hours
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Max. 3 mΩ (by voltage drop 6 V DC 40 A, reference value)
AgSnO2 type
40 A 277 V AC, 5 A 110 V DC
11,080 VA, 550 W
480 V AC, 110 V DC
40 A (Ambient temperature -40 to + 70°C)
35 A (Ambient temperature 70 to + 85°C)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Max. 1,000 A 1 ms, 3 times (Reference value)
Between open Form A contacts: 2,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact sets: 5,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact and coil: 5,000 Vrms for 1min (detection current: 10 mA)
5,000 Vrms for 1min (detection current: 10 mA)
10,000 V (Between Form A contact and coil)
30 to 110% V (at -40 to +55℃), 30 to 60% V (at +55 to +85℃)
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A)
Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s]
Min. 200x103 ope. 20 A 277 V AC
Min. 100x103 ope. 30 A 220 V AC
Min. 50x103 ope. 35 A 277 V AC
Min. 1,000 ope. 40 A 277 V AC
Min. 10x103 ope. 5 A 110 V DC
[switching frequency ON : OFF = 0.1 s : 10 s]
Min. 50x103 ope. 35 A 250 V AC (cosΦ = 0.8)
3.2 mm
Standard type
9 V DC
2 Form A
Flux-resistant
Single side stable
PC board terminal
High capacity type
25
100
Max. 75% V of rated coil voltage (Initial)
Min. 5% V of rated coil voltage (Initial)
209 mA
43.1 Ω
1,880 mW
Holding: 170 mW
(at 55℃)
110% V of rated coil voltage
150% V of rated coil voltage (*4)
(*4): Total application time: Max. 24 hours
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Max. 3 mΩ (by voltage drop 6 V DC 40 A, reference value)
AgSnO2 type
40 A 277 V AC, 5 A 110 V DC
11,080 VA, 550 W
480 V AC, 110 V DC
40 A (Ambient temperature -40 to + 70°C)
35 A (Ambient temperature 70 to + 85°C)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Max. 1,000 A 1 ms, 3 times (Reference value)
Between open Form A contacts: 2,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact sets: 5,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact and coil: 5,000 Vrms for 1min (detection current: 10 mA)
5,000 Vrms for 1min (detection current: 10 mA)
10,000 V (Between Form A contact and coil)
30 to 110% V (at -40 to +55℃), 30 to 60% V (at +55 to +85℃)
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A)
Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s]
Min. 100x103 ope. 20 A 277 V AC
Min. 30x103 ope. 35 A 277 V AC
Min. 1,000 ope. 40 A 277 V AC
Min. 10x103 ope. 5 A 110 V DC
[switching frequency ON : OFF = 0.1 s : 10 s]
Min. 30x103 ope. 35 A 250 V AC (cosΦ = 0.8)
3.2 mm
Standard type
6 V DC
2 Form A 1 Form B
Flux-resistant
Single side stable
PC board terminal
High capacity type
25
100
Max. 75% V of rated coil voltage (Initial)
Min. 5% V of rated coil voltage (Initial)
313 mA
19.1 Ω
1,880 mW
Holding: 170 mW
(at 55℃)
110% V of rated coil voltage
150% V of rated coil voltage (*4)
(*4): Total application time: Max. 24 hours
Single
Form A contact: Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Form A contact: Max. 3 mΩ (by voltage drop 6 V DC 40 A, reference value)
Form B contact: Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Form A contact: AgSnO2 type
Form B contact: Au flashed AgNi type
Form A contact: 40 A 277 V AC, 5 A 110 V DC
Form B contact: 1 A 277 V AC, 1 A 30 V DC
Form A contact:11,080 VA
Form B contact:277 VA, 30 W
Form A contact: 480 V AC, 110 V DC
Form B contact: 277 V AC, 30 V DC
Form A contact:
40 A (Ambient temperature -40 to + 70°C)
35 A (Ambient temperature 70 to + 85°C)
Form B contact:
1 A
Form A contact: 100 mA 5 V DC
Form B contact: 10 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Max. 1,000 A 1 ms, 3 times (Reference value)
Between open Form A contacts: 2,000 Vrms for 1min (detection current: 10 mA)
Between open Form B contacts: 1,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact sets: 5,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact and coil: 5,000 Vrms for 1min (detection current: 10 mA)
Between Form B contact and coil: 2,000 Vrms for 1min (detection current: 10 mA)
5,000 Vrms for 1min (detection current: 10 mA)
10,000 V (Between Form A contact and coil)
2,500 V (Between Form B contact and coil)
30 to 110% V (at -40 to +55℃), 30 to 60% V (at +55 to +85℃)
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A)
Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s]
Form A contact:
Min. 100x103 ope. 20 A 277 V AC
Min. 30x103 ope. 35 A 277 V AC
Min. 1,000 ope. 40 A 277 V AC
Min. 10x103 ope. 5 A 110 V DC
Form B contact:
Min. 100x103 ope. 1 A 277 V AC
Min. 100x103 ope. 1 A 30 V DC
[switching frequency ON : OFF = 0.1 s : 10 s]
Form A contact: Min. 30x103 ope. 35 A 250 V AC (cosΦ = 0.8)
3.2 mm
Standard type
48 V DC
2 Form A
Flux-resistant
Single side stable
PC board terminal
High capacity type
25
100
Max. 75% V of rated coil voltage (Initial)
Min. 5% V of rated coil voltage (Initial)
39 mA
1,225.5 Ω
1,880 mW
Holding: 170 mW
(at 55℃)
110% V of rated coil voltage
150% V of rated coil voltage (*4)
(*4): Total application time: Max. 24 hours
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Max. 3 mΩ (by voltage drop 6 V DC 40 A, reference value)
AgSnO2 type
40 A 277 V AC, 5 A 110 V DC
11,080 VA, 550 W
480 V AC, 110 V DC
40 A (Ambient temperature -40 to + 70°C)
35 A (Ambient temperature 70 to + 85°C)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Max. 1,000 A 1 ms, 3 times (Reference value)
Between open Form A contacts: 2,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact sets: 5,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact and coil: 5,000 Vrms for 1min (detection current: 10 mA)
5,000 Vrms for 1min (detection current: 10 mA)
10,000 V (Between Form A contact and coil)
30 to 110% V (at -40 to +55℃), 30 to 60% V (at +55 to +85℃)
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A)
Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s]
Min. 100x103 ope. 20 A 277 V AC
Min. 30x103 ope. 35 A 277 V AC
Min. 1,000 ope. 40 A 277 V AC
Min. 10x103 ope. 5 A 110 V DC
[switching frequency ON : OFF = 0.1 s : 10 s]
Min. 30x103 ope. 35 A 250 V AC (cosΦ = 0.8)
3.2 mm
Standard type
48 V DC
2 Form A 1 Form B
Flux-resistant
Single side stable
PC board terminal
High capacity type
25
100
Max. 75% V of rated coil voltage (Initial)
Min. 5% V of rated coil voltage (Initial)
39 mA
1,225.5 Ω
1,880 mW
Holding: 170 mW
(at 55℃)
110% V of rated coil voltage
150% V of rated coil voltage (*4)
(*4): Total application time: Max. 24 hours
Single
Form A contact: Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Form A contact: Max. 3 mΩ (by voltage drop 6 V DC 40 A, reference value)
Form B contact: Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Form A contact: AgSnO2 type
Form B contact: Au flashed AgNi type
Form A contact: 40 A 277 V AC, 5 A 110 V DC
Form B contact: 1 A 277 V AC, 1 A 30 V DC
Form A contact:11,080 VA
Form B contact:277 VA, 30 W
Form A contact: 480 V AC, 110 V DC
Form B contact: 277 V AC, 30 V DC
Form A contact:
40 A (Ambient temperature -40 to + 70°C)
35 A (Ambient temperature 70 to + 85°C)
Form B contact:
1 A
Form A contact: 100 mA 5 V DC
Form B contact: 10 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Max. 1,000 A 1 ms, 3 times (Reference value)
Between open Form A contacts: 2,000 Vrms for 1min (detection current: 10 mA)
Between open Form B contacts: 1,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact sets: 5,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact and coil: 5,000 Vrms for 1min (detection current: 10 mA)
Between Form B contact and coil: 2,000 Vrms for 1min (detection current: 10 mA)
5,000 Vrms for 1min (detection current: 10 mA)
10,000 V (Between Form A contact and coil)
2,500 V (Between Form B contact and coil)
30 to 110% V (at -40 to +55℃), 30 to 60% V (at +55 to +85℃)
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A)
Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s]
Form A contact:
Min. 100x103 ope. 20 A 277 V AC
Min. 30x103 ope. 35 A 277 V AC
Min. 1,000 ope. 40 A 277 V AC
Min. 10x103 ope. 5 A 110 V DC
Form B contact:
Min. 100x103 ope. 1 A 277 V AC
Min. 100x103 ope. 1 A 30 V DC
[switching frequency ON : OFF = 0.1 s : 10 s]
Form A contact: Min. 30x103 ope. 35 A 250 V AC (cosΦ = 0.8)
3.2 mm
Latest Videos

Playlist

Thumbnail for Panasonic Industrial Solutions for 5G Networking Applications

Panasonic Industrial Solutions for 5G Networking Applications

Thumbnail for New Product Spotlight: DW Series Relays

New Product Spotlight: DW Series Relays

Thumbnail for New Product Spotlight: PA-N Series General Power Relays

New Product Spotlight: PA-N Series General Power Relays

Thumbnail for New Product Introduction: HE-R Series General Power Relays

New Product Introduction: HE-R Series General Power Relays

Thumbnail for New Product Introduction: HE Series Power Relay PV Type 90A Wide Gap

New Product Introduction: HE Series Power Relay PV Type 90A Wide Gap

Thumbnail for New Product Introduction: DS-P Series

New Product Introduction: DS-P Series

Thumbnail for New Product Information: LQ Series Relays

New Product Information: LQ Series Relays

Thumbnail for New Product Introduction: HE-A Series Relays

New Product Introduction: HE-A Series Relays