| | Flux-resistant | High capacity type (10 A) | 12 V DC | 1 Form A | Single side stable | PC board terminal | Standard type | Class E insulation | Sockets are available. | 100 | 500 | Max. 70% V of Rated coil voltage (initial) | Min. 10% V of Rated coil voltage (initial) | 44 mA | 270 Ω | 530 mW | 130% V of Rated coil voltage (at 60°C) | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 10 A 250 V AC, 10 A 30 V DC | 2,500 VA, 300 W | 250 V AC, 30 V DC | 10 A | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 5,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 5 ms (at rated coil voltage, without bounce, without diode) | Max. 15 ms (at rated coil voltage, without bounce) | Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs) | Min. 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2.0 mm) | Min. 5x106 ope. (at 180 times/min.) | Ambient temperature: -40 to +60°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 13 g | Min. 100,000 ope. 10 A 250 V AC (at 20 times/min.) Min. 100,000 ope. 10 A 30 V DC (at 20 times/min.) |
| | Flux-resistant | High capacity type (10 A) | 9 V DC | 1 Form A | Single side stable | PC board terminal | Standard type | Class E insulation | Sockets are available. | 100 | 500 | Max. 70% V of Rated coil voltage (initial) | Min. 10% V of Rated coil voltage (initial) | 58 mA | 155 Ω | 530 mW | 130% V of Rated coil voltage (at 60°C) | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 10 A 250 V AC, 10 A 30 V DC | 2,500 VA, 300 W | 250 V AC, 30 V DC | 10 A | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 5,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 5 ms (at rated coil voltage, without bounce, without diode) | Max. 15 ms (at rated coil voltage, without bounce) | Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs) | Min. 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2.0 mm) | Min. 5x106 ope. (at 180 times/min.) | Ambient temperature: -40 to +60°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 13 g | Min. 100,000 ope. 10 A 250 V AC (at 20 times/min.) Min. 100,000 ope. 10 A 30 V DC (at 20 times/min.) |
| | Sealed | Standard type (5A) | 12 V DC | 1 Form C | Single side stable | PC board terminal | Standard type | Class E insulation | Sockets are available. | 100 | 500 | Max. 70% V of Rated coil voltage (initial) | Min. 10% V of Rated coil voltage (initial) | 44 mA | 270 Ω | 530 mW | 130% V of Rated coil voltage (at 60°C) | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgNi type | 5 A 250 V AC, 5 A 30 V DC | 1,250 VA, 150 W | 250 V AC, 30 V DC | 5 A | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 5,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 5 ms (at rated coil voltage, without bounce, without diode) | Max. 15 ms (at rated coil voltage, without bounce) | Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs) | Min. 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2.0 mm) | Min. 5x106 ope. (at 180 times/min.) | Ambient temperature: -40 to +60°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 13 g | Min. 100,000 ope. 5 A 250 V AC (at 6 times/min.) Min. 100,000 ope. 5 A 30 V DC (at 6 times/min.) |
| | Sealed | High capacity type (10 A) | 24 V DC | 1 Form A | Single side stable | PC board terminal | Standard type | Class E insulation | Sockets are available. | 100 | 500 | Max. 70% V of Rated coil voltage (initial) | Min. 10% V of Rated coil voltage (initial) | 22 mA | 1,100 Ω | 530 mW | 130% V of Rated coil voltage (at 60°C) | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 10 A 250 V AC, 10 A 30 V DC | 2,500 VA, 300 W | 250 V AC, 30 V DC | 10 A | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 5,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 5 ms (at rated coil voltage, without bounce, without diode) | Max. 15 ms (at rated coil voltage, without bounce) | Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs) | Min. 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2.0 mm) | Min. 5x106 ope. (at 180 times/min.) | Ambient temperature: -40 to +60°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 13 g | Min. 100,000 ope. 10 A 250 V AC (at 6 times/min.) Min. 100,000 ope. 10 A 30 V DC (at 6 times/min.) |
| | Flux-resistant | Standard type (5A) | 5 V DC | 1 Form A | Single side stable | PC board terminal | Standard type | Class E insulation | Sockets are available. | 100 | 500 | Max. 70% V of Rated coil voltage (initial) | Min. 10% V of Rated coil voltage (initial) | 106 mA | 47 Ω | 530 mW | 130% V of Rated coil voltage (at 60°C) | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 5 A 250 V AC, 5 A 30 V DC | 1,250 VA, 150 W | 250 V AC, 30 V DC | 5 A | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 5,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 5 ms (at rated coil voltage, without bounce, without diode) | Max. 15 ms (at rated coil voltage, without bounce) | Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs) | Min. 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2.0 mm) | Min. 5x106 ope. (at 180 times/min.) | Ambient temperature: -40 to +60°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 13 g | Min. 100,000 ope. 5 A 250 V AC (at 20 times/min.) Min. 100,000 ope. 5 A 30 V DC (at 20 times/min.) |
| | Sealed | Standard type (5A) | 48 V DC | 1 Form A | Single side stable | PC board terminal | Standard type | Class E insulation | Sockets are available. | 100 | 500 | Max. 70% V of Rated coil voltage (initial) | Min. 10% V of Rated coil voltage (initial) | 11 mA | 4,400 Ω | 530 mW | 130% V of Rated coil voltage (at 60°C) | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 5 A 250 V AC, 5 A 30 V DC | 1,250 VA, 150 W | 250 V AC, 30 V DC | 5 A | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 5,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 5 ms (at rated coil voltage, without bounce, without diode) | Max. 15 ms (at rated coil voltage, without bounce) | Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs) | Min. 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2.0 mm) | Min. 5x106 ope. (at 180 times/min.) | Ambient temperature: -40 to +60°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 13 g | Min. 100,000 ope. 5 A 250 V AC (at 6 times/min.) Min. 100,000 ope. 5 A 30 V DC (at 6 times/min.) |
| | Sealed | High capacity type (10 A) | 6 V DC | 1 Form A | Single side stable | PC board terminal | Standard type | Class E insulation | Sockets are available. | 100 | 500 | Max. 70% V of Rated coil voltage (initial) | Min. 10% V of Rated coil voltage (initial) | 88 mA | 68 Ω | 530 mW | 130% V of Rated coil voltage (at 60°C) | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 10 A 250 V AC, 10 A 30 V DC | 2,500 VA, 300 W | 250 V AC, 30 V DC | 10 A | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 5,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 5 ms (at rated coil voltage, without bounce, without diode) | Max. 15 ms (at rated coil voltage, without bounce) | Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs) | Min. 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2.0 mm) | Min. 5x106 ope. (at 180 times/min.) | Ambient temperature: -40 to +60°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 13 g | Min. 100,000 ope. 10 A 250 V AC (at 6 times/min.) Min. 100,000 ope. 10 A 30 V DC (at 6 times/min.) |
| | Sealed | Standard type (5A) | 9 V DC | 1 Form C | Single side stable | PC board terminal | Standard type | Class E insulation | Sockets are available. | 100 | 500 | Max. 70% V of Rated coil voltage (initial) | Min. 10% V of Rated coil voltage (initial) | 58 mA | 155 Ω | 530 mW | 130% V of Rated coil voltage (at 60°C) | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgNi type | 5 A 250 V AC, 5 A 30 V DC | 1,250 VA, 150 W | 250 V AC, 30 V DC | 5 A | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 5,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 5 ms (at rated coil voltage, without bounce, without diode) | Max. 15 ms (at rated coil voltage, without bounce) | Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs) | Min. 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2.0 mm) | Min. 5x106 ope. (at 180 times/min.) | Ambient temperature: -40 to +60°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 13 g | Min. 100,000 ope. 5 A 250 V AC (at 6 times/min.) Min. 100,000 ope. 5 A 30 V DC (at 6 times/min.) |
| | Flux-resistant | Standard type (5A) | 6 V DC | 1 Form C | Single side stable | PC board terminal | Standard type | Class E insulation | Sockets are available. | 100 | 500 | Max. 70% V of Rated coil voltage (initial) | Min. 10% V of Rated coil voltage (initial) | 88 mA | 68 Ω | 530 mW | 130% V of Rated coil voltage (at 60°C) | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgNi type | 5 A 250 V AC, 5 A 30 V DC | 1,250 VA, 150 W | 250 V AC, 30 V DC | 5 A | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 5,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 5 ms (at rated coil voltage, without bounce, without diode) | Max. 15 ms (at rated coil voltage, without bounce) | Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs) | Min. 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2.0 mm) | Min. 5x106 ope. (at 180 times/min.) | Ambient temperature: -40 to +60°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 13 g | Min. 100,000 ope. 5 A 250 V AC (at 20 times/min.) Min. 100,000 ope. 5 A 30 V DC (at 20 times/min.) |
| | Flux-resistant | High capacity type (10 A) | 24 V DC | 1 Form C | Single side stable | PC board terminal | Standard type | Class E insulation | Sockets are available. | 100 | 500 | Max. 70% V of Rated coil voltage (initial) | Min. 10% V of Rated coil voltage (initial) | 22 mA | 1,100 Ω | 530 mW | 130% V of Rated coil voltage (at 60°C) | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgNi type | 10 A 250 V AC, 10 A 30 V DC | 2,500 VA, 300 W | 250 V AC, 30 V DC | 10 A | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 5,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 5 ms (at rated coil voltage, without bounce, without diode) | Max. 15 ms (at rated coil voltage, without bounce) | Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs) | Min. 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2.0 mm) | Min. 5x106 ope. (at 180 times/min.) | Ambient temperature: -40 to +60°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 13 g | Min. 100,000 ope. 10 A 250 V AC (at 20 times/min.) Min. 100,000 ope. 10 A 30 V DC (at 20 times/min.) |