Sealed
Single side stable
Without a test button
48 V DC
250 mW
2 Form B
PC board terminal
[Between contact and coil] Min. 8 mm (Clearance and Creepage)
100
500
5.2 mA
9,216 Ω
130% V of rated coil voltage
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Au-flashed AgSnO2 type
10 A 250 V AC
2,500 VA
250 V AC
10 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 14 g
[switching frequency: 20 times/min] Min. 100x103 ope. 10 A 250 V AC
Max. 75% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
Max. 20 ms at rated coil voltage (without bounce)
Max. 20 ms at rated coil voltage (without bounce, without diode)
2,000 Vrms for 1 min (detection current: 10 mA)
Flux-resistant
Single side stable
Without a test button
12 V DC
250 mW
1 Form A
PC board terminal
[Between contact and coil] Min. 8 mm (Clearance and Creepage)
100
500
20.8 mA
576 Ω
130% V of rated coil voltage
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 250 V AC
4,000 VA
250 V AC
16 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 14 g
[switching frequency: 20 times/min] Min. 100x103 ope. 16 A 250 V AC
Max. 75% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
Max. 20 ms at rated coil voltage (without bounce)
Max. 20 ms at rated coil voltage (without bounce, without diode)
Flux-resistant
Single side stable
With a test button
24 V DC
250 mW
1 Form A
PC board terminal
[Between contact and coil] Min. 8 mm (Clearance and Creepage)
100
500
10.4 mA
2,304 Ω
130% V of rated coil voltage
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 250 V AC
4,000 VA
250 V AC
16 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 14 g
[switching frequency: 20 times/min] Min. 100x103 ope. 16 A 250 V AC
Max. 75% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
Max. 20 ms at rated coil voltage (without bounce)
Max. 20 ms at rated coil voltage (without bounce, without diode)
Sealed
Single side stable
Without a test button
5 V DC
250 mW
1 Form A
PC board terminal
[Between contact and coil] Min. 8 mm (Clearance and Creepage)
100
500
50 mA
100 Ω
130% V of rated coil voltage
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 250 V AC
4,000 VA
250 V AC
16 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 14 g
[switching frequency: 20 times/min] Min. 100x103 ope. 16 A 250 V AC
Max. 75% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
Max. 20 ms at rated coil voltage (without bounce)
Max. 20 ms at rated coil voltage (without bounce, without diode)
Sealed
Single side stable
Without a test button
24 V DC
250 mW
1 Form A
PC board terminal
[Between contact and coil] Min. 8 mm (Clearance and Creepage)
100
500
10.4 mA
2,304 Ω
130% V of rated coil voltage
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 250 V AC
4,000 VA
250 V AC
16 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 14 g
[switching frequency: 20 times/min] Min. 100x103 ope. 16 A 250 V AC
Max. 75% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
Max. 20 ms at rated coil voltage (without bounce)
Max. 20 ms at rated coil voltage (without bounce, without diode)
Sealed
Single side stable
Without a test button
12 V DC
250 mW
1 Form A
PC board terminal
[Between contact and coil] Min. 8 mm (Clearance and Creepage)
100
500
20.8 mA
576 Ω
130% V of rated coil voltage
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 250 V AC
4,000 VA
250 V AC
16 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 14 g
[switching frequency: 20 times/min] Min. 100x103 ope. 16 A 250 V AC
Max. 75% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
Max. 20 ms at rated coil voltage (without bounce)
Max. 20 ms at rated coil voltage (without bounce, without diode)
Flux-resistant
Single side stable
Without a test button
12 V DC
250 mW
1 Form B
PC board terminal
[Between contact and coil] Min. 8 mm (Clearance and Creepage)
100
500
20.8 mA
576 Ω
130% V of rated coil voltage
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 250 V AC
4,000 VA
250 V AC
16 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 14 g
[switching frequency: 20 times/min] Min. 100x103 ope. 16 A 250 V AC
Max. 75% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
Max. 20 ms at rated coil voltage (without bounce)
Max. 20 ms at rated coil voltage (without bounce, without diode)
Flux-resistant
Single side stable
With a test button
5 V DC
250 mW
1 Form B
PC board terminal
[Between contact and coil] Min. 8 mm (Clearance and Creepage)
100
500
50 mA
100 Ω
130% V of rated coil voltage
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 250 V AC
4,000 VA
250 V AC
16 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 14 g
[switching frequency: 20 times/min] Min. 100x103 ope. 16 A 250 V AC
Max. 75% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
Max. 20 ms at rated coil voltage (without bounce)
Max. 20 ms at rated coil voltage (without bounce, without diode)
Flux-resistant
Single side stable
With a test button
6 V DC
250 mW
1 Form B
PC board terminal
[Between contact and coil] Min. 8 mm (Clearance and Creepage)
100
500
41.7 mA
144 Ω
130% V of rated coil voltage
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 250 V AC
4,000 VA
250 V AC
16 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 14 g
[switching frequency: 20 times/min] Min. 100x103 ope. 16 A 250 V AC
Max. 75% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
Max. 20 ms at rated coil voltage (without bounce)
Max. 20 ms at rated coil voltage (without bounce, without diode)
Flux-resistant
Single side stable
Without a test button
6 V DC
250 mW
1 Form B
PC board terminal
[Between contact and coil] Min. 8 mm (Clearance and Creepage)
100
500
41.7 mA
144 Ω
130% V of rated coil voltage
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 250 V AC
4,000 VA
250 V AC
16 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 14 g
[switching frequency: 20 times/min] Min. 100x103 ope. 16 A 250 V AC
Max. 75% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
Max. 20 ms at rated coil voltage (without bounce)
Max. 20 ms at rated coil voltage (without bounce, without diode)