ItemPerformance characteristics
Operating Function Single side stable
Rated Coil Voltage24 V DC
Contact Arrangement1 Form A 1 Form B
AccessoriesSockets are available.
Protective ConstructionSealed
Terminal TypePC board terminal
Rated Operating Power 200 mW
Pick-Up Voltage70%V or less of rated coil voltage (Initial)
Drop-Out Voltage10%V or more of rated coil voltage (Initial)
Max. Switching Voltage250 V AC, 125 V DC (0.2 A)
Max. Switching Current8 A (AC, DC)
Min. Switching Load (Reference Value) 10 mA 5 V DC
Contact MaterialAu-flashed AgSnO2 type
Mechanical LifeMin. 50x106 ope. (switching frequency: at 300 times/min)
Electrical LifeMin. 1x105
Dielectric Strength (Initial): Between Open Contacts1,000 Vrms for 1 min (detection current: 10 mA)
Dielectric Strength (Initial): Between Contact and Coil4,000 Vrms for 1 min (detection current: 10 mA)
Ambient TemperatureAmbient temperature: –40 to +70°C
Humidity: 5 to 85% R.H.
(Not freezing and condensing at low temperature)
Insulation Distance[Between input and output]
6 mm
Packing QuantityCarton
Packing Quantity; Inner Carton (Pcs.) 50
Packing Quantity; Outer Carton (Pcs.)500
Operate Voltage (@20oC)Max. 70% V of rated coil voltage (Initial)
Release Voltage (at20°C) Min. 10% V of rated coil voltage (Initial)
Rated Operating Current [±10%] (at 20°C)8.3 mA
Resistance [±10%] (at 20°C) 2,880 Ω
Max. Allowable Voltage (at 20°C 68°F)130% V of rated coil voltage
Contact Resistance (Initial)Max. 30 mΩ (by voltage drop 6 V DC 1 A)
Contact Rating (Resistive Load)8 A 250 V AC, 8 A 30 V DC
Insulation Resistance (Initial)Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Surge Withstand Voltage (Initial): Between Contact and Coil10,000 V
Operate Time (Initial) (At 20oC)Max. 10 ms at rated coil voltage (without bounce)
Release Time (Initial) (at 20°C) Max. 8 ms at rated coil voltage (without bounce, without diode)
Hock Resistance (Functional)98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
Hock Resistance (Destructive)980 m/s2 (half-sine shock pulse: 6 ms)
Vibration Resistance (Functional)10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 μs)
Vibration Resistance (Destructive)10 to 55 Hz (at double amplitude of 3 mm)
Weight (Typ.)Approx. 6 g
ConditionsAmbient temperature: -40 to +70℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Resistive Load[switching frequency: 20 times/min]
Min. 100x103 ope. 8 A 250 V AC
Min. 100x103 ope. 8 A 30 V DC
Dielectric Strength (Initial): Between Contact Sets4,000 Vrms for 1 min
Max. Switching Power (Resistive Load) 2,000 VA, 240 W

Stock check

Model image for ADY30024

ADY30024

Latest Videos

Playlist

Thumbnail for Panasonic Industrial Solutions for 5G Networking Applications

Panasonic Industrial Solutions for 5G Networking Applications

Thumbnail for New Product Spotlight: DW Series Relays

New Product Spotlight: DW Series Relays

Thumbnail for New Product Spotlight: PA-N Series General Power Relays

New Product Spotlight: PA-N Series General Power Relays

Thumbnail for New Product Introduction: HE-R Series General Power Relays

New Product Introduction: HE-R Series General Power Relays

Thumbnail for New Product Introduction: HE Series Power Relay PV Type 90A Wide Gap

New Product Introduction: HE Series Power Relay PV Type 90A Wide Gap

Thumbnail for New Product Introduction: DS-P Series

New Product Introduction: DS-P Series

Thumbnail for New Product Information: LQ Series Relays

New Product Information: LQ Series Relays

Thumbnail for New Product Introduction: HE-A Series Relays

New Product Introduction: HE-A Series Relays