Specifications table for model ADZS12112
ItemPerformance characteristics
Operating Function 1 coil latching
Rated Coil Voltage12 V DC
Protective ConstructionDust Cover
Terminal TypeVertical terminal
Contact TypeHigh switching capacity
Packing Quantity; Inner Carton (Pcs.) 20
Packing Quantity; Outer Carton (Pcs.)200
Set Voltage Max. 70% V of rated coil voltage (Initial)
Reset VoltageMax. 70% V of rated coil voltage (Initial)
Rated Operating Current [±10%] (at 20°C)125 mA
Resistance [±10%] (at 20°C) 96 Ω
Rated Operating Power 1.5 W
Max. Allowable Voltage (at 20°C 68°F)130% V of rated coil voltage
Contact Arrangement1 Form A
Contact ShapeSingle
Contact Resistance (Initial)Max. 1 mΩ (at 90 A), Max. 5 mΩ (at 10 A)
Contact MaterialAgSnO2 type
Contact Rating (Resistive Load)90 A 250 V AC
Max. Switching Power (Resistive Load) 24,840 VA
Max. Switching Voltage276 V AC
Max. Switching Current90 A (AC)
Min. Switching Load (Reference Value) 100 mA 125 V AC
Insulation Resistance (Initial)Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric Strength (Initial): Between Open Contacts2,000 Vrms for 1 min (detection current: 10 mA)
Dielectric Strength (Initial): Between Contact and Coil4,000 Vrms for 1 min (detection current: 10 mA)
Surge Withstand Voltage (Initial): Between Contact and Coil12,000 V
Time (Initial) (at 20°C 68°F) (Initial) Max. 20 ms at rated coil voltage (without bounce)
Reset Time (Initial) (at20°C 68°F) Max. 20 ms at rated coil voltage (without bounce)
Hock Resistance (Functional)300 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
Hock Resistance (Destructive)1,000 m/s2 (half-sine shock pulse: 6 ms)
Vibration Resistance (Functional)10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 μs)
Vibration Resistance (Destructive)10 to 55 Hz (at double amplitude of 2 mm)
Mechanical LifeMin. 100x103 ope. (switching frequency: at 180 times/min)
ConditionsAmbient temperature: -40 to +85℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Weight (Typ.)Approx. 45 g
Resistive Load[switching frequency: at 20 times/min (ON : OFF = 2 s : 4 s)]
Min. 10x103 ope. 90 A 250 V AC
UC3 Class (IEC62055-31)[switching frequency ON : OFF = 10 s : 20 s]
Min. 10x103 ope. 90 A 276 V AC
(cosΦ = 1 : 5,000 cycles, cosΦ = 0.5 : 5,000 cycles)
Contact Voltage Drop (Initial)Max. 0.09 V (at 90 A), Max. 0.05 V (at 10 A)

Stock check

Model image for ADZS12112

ADZS12112

Latest Videos

Playlist

Thumbnail for Panasonic Industrial Solutions for 5G Networking Applications

Panasonic Industrial Solutions for 5G Networking Applications

Thumbnail for New Product Spotlight: DW Series Relays

New Product Spotlight: DW Series Relays

Thumbnail for New Product Spotlight: PA-N Series General Power Relays

New Product Spotlight: PA-N Series General Power Relays

Thumbnail for New Product Introduction: HE-R Series General Power Relays

New Product Introduction: HE-R Series General Power Relays

Thumbnail for New Product Introduction: HE Series Power Relay PV Type 90A Wide Gap

New Product Introduction: HE Series Power Relay PV Type 90A Wide Gap

Thumbnail for New Product Introduction: DS-P Series

New Product Introduction: DS-P Series

Thumbnail for New Product Information: LQ Series Relays

New Product Information: LQ Series Relays

Thumbnail for New Product Introduction: HE-A Series Relays

New Product Introduction: HE-A Series Relays