The HE-S Series is a compact Power Relay with low operating power and high-capacity switching. This Relay features contacts with long electrical life and a high-capacity resistive switching load rating of 35A at 277VAC for 50,000 cycles.
This Relay also features a mirror contact structure (compliant with EN60947-4-1) which uses a 2 Form A coupled with a 1 Form B contact arrangement.
Features:
35A @ 277VAC (50,000 Cycles N.O.)
30 x 36 x 40 mm Case Size
1,880 mW Nominal Operating Power/170mW Coil Holding Power
Large Contact Gap and Insulation Distance
Mirror Contact Mechanisms
RoHS/REACH Compliant
Benefits:
High-Capacity and Long Electrical Life
Takes up Less Board Space
Low Power Operation
Compliant with VDE126 and EN61810-1 Standards
1 Form B Contact Can Be Used To Monitor the Condition of N.O Contacts for Weld Detection
Environmentally Friendly
HE-S Series Relays
Part number list
Results 20
Models table for series HE-S Series Relays
Part No.
Datasheet
Electrical Life Type
Rated Coil Voltage
Contact Arrangement
Protective Construction
Operating Function
Terminal Type
Contact Type
Packing Quantity; Inner Carton (Pcs.)
Packing Quantity; Outer Carton (Pcs.)
Operate Voltage (@20oC)
Release Voltage (at20°C)
Rated Operating Current [±10%] (at 20°C)
Resistance [±10%] (at 20°C)
Rated Operating Power
Max. Allowable Voltage
Contact Shape
Contact Resistance (Initial)
Contact Material
Contact Rating (Resistive Load)
Max. Switching Power (Resistive Load)
Max. Switching Voltage
Max. Switching Current
Min. Switching Load (Reference Value)
Insulation Resistance (Initial)
Hort Current (A Contact, Initial)
Dielectric Strength (Initial): Between Open Contacts
Dielectric Strength (Initial): Between Contact Sets
Dielectric Strength (Initial): Between Contact and Coil
Dielectric Strength: Between Form A Contact and Form B Contact
Surge Withstand Voltage (Initial): Between Contact and Coil
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A) Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s] Min. 100x103 ope. 20 A 277 V AC Min. 30x103 ope. 35 A 277 V AC Min. 1,000 ope. 40 A 277 V AC Min. 10x103 ope. 5 A 110 V DC
[switching frequency ON : OFF = 0.1 s : 10 s] Min. 30x103 ope. 35 A 250 V AC (cosΦ = 0.8)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A) Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s] Min. 100x103 ope. 20 A 277 V AC Min. 30x103 ope. 35 A 277 V AC Min. 1,000 ope. 40 A 277 V AC Min. 10x103 ope. 5 A 110 V DC
[switching frequency ON : OFF = 0.1 s : 10 s] Min. 30x103 ope. 35 A 250 V AC (cosΦ = 0.8)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A) Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s] Min. 200x103 ope. 20 A 277 V AC Min. 100x103 ope. 30 A 220 V AC Min. 50x103 ope. 35 A 277 V AC Min. 1,000 ope. 40 A 277 V AC Min. 10x103 ope. 5 A 110 V DC
[switching frequency ON : OFF = 0.1 s : 10 s] Min. 50x103 ope. 35 A 250 V AC (cosΦ = 0.8)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A) Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s] Min. 100x103 ope. 20 A 277 V AC Min. 30x103 ope. 35 A 277 V AC Min. 1,000 ope. 40 A 277 V AC Min. 10x103 ope. 5 A 110 V DC
[switching frequency ON : OFF = 0.1 s : 10 s] Min. 30x103 ope. 35 A 250 V AC (cosΦ = 0.8)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A) Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s] Min. 100x103 ope. 20 A 277 V AC Min. 30x103 ope. 35 A 277 V AC Min. 1,000 ope. 40 A 277 V AC Min. 10x103 ope. 5 A 110 V DC
[switching frequency ON : OFF = 0.1 s : 10 s] Min. 30x103 ope. 35 A 250 V AC (cosΦ = 0.8)
(at 55℃) 110% V of rated coil voltage 150% V of rated coil voltage (*4) (*4): Total application time: Max. 24 hours
Single
Form A contact: Max. 100 mΩ (by voltage drop 6 V DC 1 A) Form A contact: Max. 3 mΩ (by voltage drop 6 V DC 40 A, reference value) Form B contact: Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Form A contact: AgSnO2 type Form B contact: Au flashed AgNi type
Form A contact: 40 A 277 V AC, 5 A 110 V DC Form B contact: 1 A 277 V AC, 1 A 30 V DC
Form A contact:11,080 VA Form B contact:277 VA, 30 W
Form A contact: 480 V AC, 110 V DC Form B contact: 277 V AC, 30 V DC
Form A contact: 40 A (Ambient temperature -40 to + 70°C) 35 A (Ambient temperature 70 to + 85°C) Form B contact: 1 A
Form A contact: 100 mA 5 V DC Form B contact: 10 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Max. 1,000 A 1 ms, 3 times (Reference value)
Between open Form A contacts: 2,000 Vrms for 1min (detection current: 10 mA) Between open Form B contacts: 1,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact sets: 5,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact and coil: 5,000 Vrms for 1min (detection current: 10 mA) Between Form B contact and coil: 2,000 Vrms for 1min (detection current: 10 mA)
5,000 Vrms for 1min (detection current: 10 mA)
10,000 V (Between Form A contact and coil) 2,500 V (Between Form B contact and coil)
30 to 110% V (at -40 to +55℃), 30 to 60% V (at +55 to +85℃)
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A) Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s] Form A contact: Min. 100x103 ope. 20 A 277 V AC Min. 30x103 ope. 35 A 277 V AC Min. 1,000 ope. 40 A 277 V AC Min. 10x103 ope. 5 A 110 V DC Form B contact: Min. 100x103 ope. 1 A 277 V AC Min. 100x103 ope. 1 A 30 V DC
[switching frequency ON : OFF = 0.1 s : 10 s] Form A contact: Min. 30x103 ope. 35 A 250 V AC (cosΦ = 0.8)
(at 55℃) 110% V of rated coil voltage 150% V of rated coil voltage (*4) (*4): Total application time: Max. 24 hours
Single
Form A contact: Max. 100 mΩ (by voltage drop 6 V DC 1 A) Form A contact: Max. 3 mΩ (by voltage drop 6 V DC 40 A, reference value) Form B contact: Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Form A contact: AgSnO2 type Form B contact: Au flashed AgNi type
Form A contact: 40 A 277 V AC, 5 A 110 V DC Form B contact: 1 A 277 V AC, 1 A 30 V DC
Form A contact:11,080 VA Form B contact:277 VA, 30 W
Form A contact: 480 V AC, 110 V DC Form B contact: 277 V AC, 30 V DC
Form A contact: 40 A (Ambient temperature -40 to + 70°C) 35 A (Ambient temperature 70 to + 85°C) Form B contact: 1 A
Form A contact: 100 mA 5 V DC Form B contact: 10 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Max. 1,000 A 1 ms, 3 times (Reference value)
Between open Form A contacts: 2,000 Vrms for 1min (detection current: 10 mA) Between open Form B contacts: 1,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact sets: 5,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact and coil: 5,000 Vrms for 1min (detection current: 10 mA) Between Form B contact and coil: 2,000 Vrms for 1min (detection current: 10 mA)
5,000 Vrms for 1min (detection current: 10 mA)
10,000 V (Between Form A contact and coil) 2,500 V (Between Form B contact and coil)
30 to 110% V (at -40 to +55℃), 30 to 60% V (at +55 to +85℃)
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A) Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s] Form A contact: Min. 100x103 ope. 20 A 277 V AC Min. 30x103 ope. 35 A 277 V AC Min. 1,000 ope. 40 A 277 V AC Min. 10x103 ope. 5 A 110 V DC Form B contact: Min. 100x103 ope. 1 A 277 V AC Min. 100x103 ope. 1 A 30 V DC
[switching frequency ON : OFF = 0.1 s : 10 s] Form A contact: Min. 30x103 ope. 35 A 250 V AC (cosΦ = 0.8)
(at 55℃) 110% V of rated coil voltage 150% V of rated coil voltage (*4) (*4): Total application time: Max. 24 hours
Single
Form A contact: Max. 100 mΩ (by voltage drop 6 V DC 1 A) Form A contact: Max. 3 mΩ (by voltage drop 6 V DC 40 A, reference value) Form B contact: Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Form A contact: AgSnO2 type Form B contact: Au flashed AgNi type
Form A contact: 40 A 277 V AC, 5 A 110 V DC Form B contact: 1 A 277 V AC, 1 A 30 V DC
Form A contact:11,080 VA Form B contact:277 VA, 30 W
Form A contact: 480 V AC, 110 V DC Form B contact: 277 V AC, 30 V DC
Form A contact: 40 A (Ambient temperature -40 to + 70°C) 35 A (Ambient temperature 70 to + 85°C) Form B contact: 1 A
Form A contact: 100 mA 5 V DC Form B contact: 10 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Max. 1,000 A 1 ms, 3 times (Reference value)
Between open Form A contacts: 2,000 Vrms for 1min (detection current: 10 mA) Between open Form B contacts: 1,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact sets: 5,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact and coil: 5,000 Vrms for 1min (detection current: 10 mA) Between Form B contact and coil: 2,000 Vrms for 1min (detection current: 10 mA)
5,000 Vrms for 1min (detection current: 10 mA)
10,000 V (Between Form A contact and coil) 2,500 V (Between Form B contact and coil)
30 to 110% V (at -40 to +55℃), 30 to 60% V (at +55 to +85℃)
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A) Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s] Form A contact: Min. 200x103 ope. 20 A 277 V AC Min. 100x103 ope. 30 A 220 V AC Min. 50x103 ope. 35 A 277 V AC Min. 1,000 ope. 40 A 277 V AC Min. 10x103 ope. 5 A 110 V DC Form B contact: Min. 100x103 ope. 1 A 277 V AC Form B contact: Min. 100x103 ope. 1 A 30 V DC
[switching frequency ON : OFF = 0.1 s : 10 s] Form A contact: Min. 5x104 35 A 250 V AC (cosΦ = 0.8)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A) Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s] Min. 200x103 ope. 20 A 277 V AC Min. 100x103 ope. 30 A 220 V AC Min. 50x103 ope. 35 A 277 V AC Min. 1,000 ope. 40 A 277 V AC Min. 10x103 ope. 5 A 110 V DC
[switching frequency ON : OFF = 0.1 s : 10 s] Min. 50x103 ope. 35 A 250 V AC (cosΦ = 0.8)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A) Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s] Min. 200x103 ope. 20 A 277 V AC Min. 100x103 ope. 30 A 220 V AC Min. 50x103 ope. 35 A 277 V AC Min. 1,000 ope. 40 A 277 V AC Min. 10x103 ope. 5 A 110 V DC
[switching frequency ON : OFF = 0.1 s : 10 s] Min. 50x103 ope. 35 A 250 V AC (cosΦ = 0.8)
3.2 mm
Models table for series HE-S Series Relays
Part No.
Datasheet
Electrical Life Type
Rated Coil Voltage
Contact Arrangement
Protective Construction
Operating Function
Terminal Type
Contact Type
Packing Quantity; Inner Carton (Pcs.)
Packing Quantity; Outer Carton (Pcs.)
Operate Voltage (@20oC)
Release Voltage (at20°C)
Rated Operating Current [±10%] (at 20°C)
Resistance [±10%] (at 20°C)
Rated Operating Power
Max. Allowable Voltage
Contact Shape
Contact Resistance (Initial)
Contact Material
Contact Rating (Resistive Load)
Max. Switching Power (Resistive Load)
Max. Switching Voltage
Max. Switching Current
Min. Switching Load (Reference Value)
Insulation Resistance (Initial)
Hort Current (A Contact, Initial)
Dielectric Strength (Initial): Between Open Contacts
Dielectric Strength (Initial): Between Contact Sets
Dielectric Strength (Initial): Between Contact and Coil
Dielectric Strength: Between Form A Contact and Form B Contact
Surge Withstand Voltage (Initial): Between Contact and Coil
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A) Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s] Min. 100x103 ope. 20 A 277 V AC Min. 30x103 ope. 35 A 277 V AC Min. 1,000 ope. 40 A 277 V AC Min. 10x103 ope. 5 A 110 V DC
[switching frequency ON : OFF = 0.1 s : 10 s] Min. 30x103 ope. 35 A 250 V AC (cosΦ = 0.8)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A) Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s] Min. 100x103 ope. 20 A 277 V AC Min. 30x103 ope. 35 A 277 V AC Min. 1,000 ope. 40 A 277 V AC Min. 10x103 ope. 5 A 110 V DC
[switching frequency ON : OFF = 0.1 s : 10 s] Min. 30x103 ope. 35 A 250 V AC (cosΦ = 0.8)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A) Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s] Min. 200x103 ope. 20 A 277 V AC Min. 100x103 ope. 30 A 220 V AC Min. 50x103 ope. 35 A 277 V AC Min. 1,000 ope. 40 A 277 V AC Min. 10x103 ope. 5 A 110 V DC
[switching frequency ON : OFF = 0.1 s : 10 s] Min. 50x103 ope. 35 A 250 V AC (cosΦ = 0.8)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A) Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s] Min. 100x103 ope. 20 A 277 V AC Min. 30x103 ope. 35 A 277 V AC Min. 1,000 ope. 40 A 277 V AC Min. 10x103 ope. 5 A 110 V DC
[switching frequency ON : OFF = 0.1 s : 10 s] Min. 30x103 ope. 35 A 250 V AC (cosΦ = 0.8)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A) Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s] Min. 100x103 ope. 20 A 277 V AC Min. 30x103 ope. 35 A 277 V AC Min. 1,000 ope. 40 A 277 V AC Min. 10x103 ope. 5 A 110 V DC
[switching frequency ON : OFF = 0.1 s : 10 s] Min. 30x103 ope. 35 A 250 V AC (cosΦ = 0.8)
(at 55℃) 110% V of rated coil voltage 150% V of rated coil voltage (*4) (*4): Total application time: Max. 24 hours
Single
Form A contact: Max. 100 mΩ (by voltage drop 6 V DC 1 A) Form A contact: Max. 3 mΩ (by voltage drop 6 V DC 40 A, reference value) Form B contact: Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Form A contact: AgSnO2 type Form B contact: Au flashed AgNi type
Form A contact: 40 A 277 V AC, 5 A 110 V DC Form B contact: 1 A 277 V AC, 1 A 30 V DC
Form A contact:11,080 VA Form B contact:277 VA, 30 W
Form A contact: 480 V AC, 110 V DC Form B contact: 277 V AC, 30 V DC
Form A contact: 40 A (Ambient temperature -40 to + 70°C) 35 A (Ambient temperature 70 to + 85°C) Form B contact: 1 A
Form A contact: 100 mA 5 V DC Form B contact: 10 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Max. 1,000 A 1 ms, 3 times (Reference value)
Between open Form A contacts: 2,000 Vrms for 1min (detection current: 10 mA) Between open Form B contacts: 1,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact sets: 5,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact and coil: 5,000 Vrms for 1min (detection current: 10 mA) Between Form B contact and coil: 2,000 Vrms for 1min (detection current: 10 mA)
5,000 Vrms for 1min (detection current: 10 mA)
10,000 V (Between Form A contact and coil) 2,500 V (Between Form B contact and coil)
30 to 110% V (at -40 to +55℃), 30 to 60% V (at +55 to +85℃)
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A) Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s] Form A contact: Min. 100x103 ope. 20 A 277 V AC Min. 30x103 ope. 35 A 277 V AC Min. 1,000 ope. 40 A 277 V AC Min. 10x103 ope. 5 A 110 V DC Form B contact: Min. 100x103 ope. 1 A 277 V AC Min. 100x103 ope. 1 A 30 V DC
[switching frequency ON : OFF = 0.1 s : 10 s] Form A contact: Min. 30x103 ope. 35 A 250 V AC (cosΦ = 0.8)
(at 55℃) 110% V of rated coil voltage 150% V of rated coil voltage (*4) (*4): Total application time: Max. 24 hours
Single
Form A contact: Max. 100 mΩ (by voltage drop 6 V DC 1 A) Form A contact: Max. 3 mΩ (by voltage drop 6 V DC 40 A, reference value) Form B contact: Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Form A contact: AgSnO2 type Form B contact: Au flashed AgNi type
Form A contact: 40 A 277 V AC, 5 A 110 V DC Form B contact: 1 A 277 V AC, 1 A 30 V DC
Form A contact:11,080 VA Form B contact:277 VA, 30 W
Form A contact: 480 V AC, 110 V DC Form B contact: 277 V AC, 30 V DC
Form A contact: 40 A (Ambient temperature -40 to + 70°C) 35 A (Ambient temperature 70 to + 85°C) Form B contact: 1 A
Form A contact: 100 mA 5 V DC Form B contact: 10 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Max. 1,000 A 1 ms, 3 times (Reference value)
Between open Form A contacts: 2,000 Vrms for 1min (detection current: 10 mA) Between open Form B contacts: 1,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact sets: 5,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact and coil: 5,000 Vrms for 1min (detection current: 10 mA) Between Form B contact and coil: 2,000 Vrms for 1min (detection current: 10 mA)
5,000 Vrms for 1min (detection current: 10 mA)
10,000 V (Between Form A contact and coil) 2,500 V (Between Form B contact and coil)
30 to 110% V (at -40 to +55℃), 30 to 60% V (at +55 to +85℃)
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A) Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s] Form A contact: Min. 100x103 ope. 20 A 277 V AC Min. 30x103 ope. 35 A 277 V AC Min. 1,000 ope. 40 A 277 V AC Min. 10x103 ope. 5 A 110 V DC Form B contact: Min. 100x103 ope. 1 A 277 V AC Min. 100x103 ope. 1 A 30 V DC
[switching frequency ON : OFF = 0.1 s : 10 s] Form A contact: Min. 30x103 ope. 35 A 250 V AC (cosΦ = 0.8)
(at 55℃) 110% V of rated coil voltage 150% V of rated coil voltage (*4) (*4): Total application time: Max. 24 hours
Single
Form A contact: Max. 100 mΩ (by voltage drop 6 V DC 1 A) Form A contact: Max. 3 mΩ (by voltage drop 6 V DC 40 A, reference value) Form B contact: Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Form A contact: AgSnO2 type Form B contact: Au flashed AgNi type
Form A contact: 40 A 277 V AC, 5 A 110 V DC Form B contact: 1 A 277 V AC, 1 A 30 V DC
Form A contact:11,080 VA Form B contact:277 VA, 30 W
Form A contact: 480 V AC, 110 V DC Form B contact: 277 V AC, 30 V DC
Form A contact: 40 A (Ambient temperature -40 to + 70°C) 35 A (Ambient temperature 70 to + 85°C) Form B contact: 1 A
Form A contact: 100 mA 5 V DC Form B contact: 10 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Max. 1,000 A 1 ms, 3 times (Reference value)
Between open Form A contacts: 2,000 Vrms for 1min (detection current: 10 mA) Between open Form B contacts: 1,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact sets: 5,000 Vrms for 1min (detection current: 10 mA)
Between Form A contact and coil: 5,000 Vrms for 1min (detection current: 10 mA) Between Form B contact and coil: 2,000 Vrms for 1min (detection current: 10 mA)
5,000 Vrms for 1min (detection current: 10 mA)
10,000 V (Between Form A contact and coil) 2,500 V (Between Form B contact and coil)
30 to 110% V (at -40 to +55℃), 30 to 60% V (at +55 to +85℃)
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A) Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s] Form A contact: Min. 200x103 ope. 20 A 277 V AC Min. 100x103 ope. 30 A 220 V AC Min. 50x103 ope. 35 A 277 V AC Min. 1,000 ope. 40 A 277 V AC Min. 10x103 ope. 5 A 110 V DC Form B contact: Min. 100x103 ope. 1 A 277 V AC Form B contact: Min. 100x103 ope. 1 A 30 V DC
[switching frequency ON : OFF = 0.1 s : 10 s] Form A contact: Min. 5x104 35 A 250 V AC (cosΦ = 0.8)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A) Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s] Min. 200x103 ope. 20 A 277 V AC Min. 100x103 ope. 30 A 220 V AC Min. 50x103 ope. 35 A 277 V AC Min. 1,000 ope. 40 A 277 V AC Min. 10x103 ope. 5 A 110 V DC
[switching frequency ON : OFF = 0.1 s : 10 s] Min. 50x103 ope. 35 A 250 V AC (cosΦ = 0.8)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 5x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ (Max. carrying current 40 A) Ambient temperature: -40 to +85℃ (Max. carrying current 35 A, transport and storage) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx.64g
[switching frequency ON : OFF = 1 s : 9 s] Min. 200x103 ope. 20 A 277 V AC Min. 100x103 ope. 30 A 220 V AC Min. 50x103 ope. 35 A 277 V AC Min. 1,000 ope. 40 A 277 V AC Min. 10x103 ope. 5 A 110 V DC
[switching frequency ON : OFF = 0.1 s : 10 s] Min. 50x103 ope. 35 A 250 V AC (cosΦ = 0.8)