| | Tab terminal (TMP type) PCB side three terminals (includes one dummy terminal) | High sensitive type | Class F insulation | 48 V DC | Flux-resistant | Single side stable | [Between contact and coil] Clearance: Min. 8 mm, Creepage: Min. 9.5 mm | 100 | 500 | Max. 75% V of Rated coil voltage (initial) | Min. 5% V of Rated coil voltage (initial) | 4.2 mA | 11,520 Ω | 200 mW | 145% V of Rated coil voltage | 1 Form A | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 16 A 277 V AC | 4,432 VA | 277 V AC | 16 A | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 4,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 20 ms (at rated coil voltage, without bounce) | Max. 25 ms (at rated coil voltage, without bounce, with diode) | Min. 200 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs) | Min. 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 2x106 ope. (at 180 times/min.) | Ambient temperature: -40 to +85°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 17 g |
| | Tab terminal (TMP type) PCB side three terminals (includes one dummy terminal) | High sensitive type | Class F insulation | 24 V DC | Flux-resistant | Single side stable | [Between contact and coil] Clearance: Min. 8 mm, Creepage: Min. 9.5 mm | 100 | 500 | Max. 75% V of Rated coil voltage (initial) | Min. 5% V of Rated coil voltage (initial) | 8.3 mA | 2,880 Ω | 200 mW | 145% V of Rated coil voltage | 1 Form A | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 16 A 277 V AC | 4,432 VA | 277 V AC | 16 A | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 4,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 20 ms (at rated coil voltage, without bounce) | Max. 25 ms (at rated coil voltage, without bounce, with diode) | Min. 200 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs) | Min. 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 2x106 ope. (at 180 times/min.) | Ambient temperature: -40 to +85°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 17 g |
| | Tab terminal (TMP type) PCB side three terminals | High sensitive type | Class B insulation | 6 V DC | Flux-resistant | Single side stable | [Between contact and coil] Clearance: Min. 8 mm, Creepage: Min. 9.5 mm | 100 | 500 | Max. 75% V of Rated coil voltage (initial) | Min. 5% V of Rated coil voltage (initial) | 33.3 mA | 180 Ω | 200 mW | 145% V of Rated coil voltage | 1 Form A | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 16 A 277 V AC | 4,432 VA | 277 V AC | 16 A | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 4,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 20 ms (at rated coil voltage, without bounce) | Max. 25 ms (at rated coil voltage, without bounce, with diode) | Min. 200 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs) | Min. 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 2x106 ope. (at 180 times/min.) | Ambient temperature: -40 to +85°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 17 g |
| | Tab terminal (TMP type) PCB side three terminals | High sensitive type | Class B insulation | 12 V DC | Flux-resistant | Single side stable | [Between contact and coil] Clearance: Min. 8 mm, Creepage: Min. 9.5 mm | 100 | 500 | Max. 75% V of Rated coil voltage (initial) | Min. 5% V of Rated coil voltage (initial) | 16.7 mA | 720 Ω | 200 mW | 145% V of Rated coil voltage | 1 Form A | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 16 A 277 V AC | 4,432 VA | 277 V AC | 16 A | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 4,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 20 ms (at rated coil voltage, without bounce) | Max. 25 ms (at rated coil voltage, without bounce, with diode) | Min. 200 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs) | Min. 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 2x106 ope. (at 180 times/min.) | Ambient temperature: -40 to +85°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 17 g |
| | Tab terminal (TMP type) PCB side three terminals | High sensitive type | Class B insulation | 48 V DC | Flux-resistant | Single side stable | [Between contact and coil] Clearance: Min. 8 mm, Creepage: Min. 9.5 mm | 100 | 500 | Max. 75% V of Rated coil voltage (initial) | Min. 5% V of Rated coil voltage (initial) | 4.2 mA | 11,520 Ω | 200 mW | 145% V of Rated coil voltage | 1 Form A | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 16 A 277 V AC | 4,432 VA | 277 V AC | 16 A | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 4,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 20 ms (at rated coil voltage, without bounce) | Max. 25 ms (at rated coil voltage, without bounce, with diode) | Min. 200 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs) | Min. 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 2x106 ope. (at 180 times/min.) | Ambient temperature: -40 to +85°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 17 g |
| | Tab terminal (TMP type) PCB side three terminals | High sensitive type | Class F insulation | 5 V DC | Flux-resistant | Single side stable | [Between contact and coil] Clearance: Min. 8 mm, Creepage: Min. 9.5 mm | 100 | 500 | Max. 75% V of Rated coil voltage (initial) | Min. 5% V of Rated coil voltage (initial) | 40 mA | 125 Ω | 200 mW | 145% V of Rated coil voltage | 1 Form A | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 16 A 277 V AC | 4,432 VA | 277 V AC | 16 A | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 4,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 20 ms (at rated coil voltage, without bounce) | Max. 25 ms (at rated coil voltage, without bounce, with diode) | Min. 200 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs) | Min. 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 2x106 ope. (at 180 times/min.) | Ambient temperature: -40 to +85°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 17 g |
| | Tab terminal (TMP type) PCB side three terminals | High sensitive type | Class F insulation | 6 V DC | Flux-resistant | Single side stable | [Between contact and coil] Clearance: Min. 8 mm, Creepage: Min. 9.5 mm | 100 | 500 | Max. 75% V of Rated coil voltage (initial) | Min. 5% V of Rated coil voltage (initial) | 33.3 mA | 180 Ω | 200 mW | 145% V of Rated coil voltage | 1 Form A | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 16 A 277 V AC | 4,432 VA | 277 V AC | 16 A | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 4,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 20 ms (at rated coil voltage, without bounce) | Max. 25 ms (at rated coil voltage, without bounce, with diode) | Min. 200 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs) | Min. 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 2x106 ope. (at 180 times/min.) | Ambient temperature: -40 to +85°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 17 g |
| | Tab terminal (TMP type) PCB side three terminals | High sensitive type | Class F insulation | 12 V DC | Flux-resistant | Single side stable | [Between contact and coil] Clearance: Min. 8 mm, Creepage: Min. 9.5 mm | 100 | 500 | Max. 75% V of Rated coil voltage (initial) | Min. 5% V of Rated coil voltage (initial) | 16.7 mA | 720 Ω | 200 mW | 145% V of Rated coil voltage | 1 Form A | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 16 A 277 V AC | 4,432 VA | 277 V AC | 16 A | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 4,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 20 ms (at rated coil voltage, without bounce) | Max. 25 ms (at rated coil voltage, without bounce, with diode) | Min. 200 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs) | Min. 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 2x106 ope. (at 180 times/min.) | Ambient temperature: -40 to +85°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 17 g |
| | Tab terminal (TMP type) PCB side three terminals | High sensitive type | Class F insulation | 48 V DC | Flux-resistant | Single side stable | [Between contact and coil] Clearance: Min. 8 mm, Creepage: Min. 9.5 mm | 100 | 500 | Max. 75% V of Rated coil voltage (initial) | Min. 5% V of Rated coil voltage (initial) | 4.2 mA | 11,520 Ω | 200 mW | 145% V of Rated coil voltage | 1 Form A | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 16 A 277 V AC | 4,432 VA | 277 V AC | 16 A | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 4,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 20 ms (at rated coil voltage, without bounce) | Max. 25 ms (at rated coil voltage, without bounce, with diode) | Min. 200 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs) | Min. 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 2x106 ope. (at 180 times/min.) | Ambient temperature: -40 to +85°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 17 g |
| | Tab terminal (TMP type) PCB side four terminals | High sensitive type | Class B insulation | 9 V DC | Flux-resistant | Single side stable | [Between contact and coil] Clearance: Min. 8 mm, Creepage: Min. 9.5 mm | 100 | 500 | Max. 75% V of Rated coil voltage (initial) | Min. 5% V of Rated coil voltage (initial) | 22.2 mA | 405 Ω | 200 mW | 145% V of Rated coil voltage | 1 Form A | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 16 A 277 V AC | 4,432 VA | 277 V AC | 16 A | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 4,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 20 ms (at rated coil voltage, without bounce) | Max. 25 ms (at rated coil voltage, without bounce, with diode) | Min. 200 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs) | Min. 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 2x106 ope. (at 180 times/min.) | Ambient temperature: -40 to +85°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 17 g |