Part Number List

Results 112
Models table for series LE Series Relays
Part No.DatasheetTerminal TypeRated Operating Power Type Coil Insulation ClassRated Coil VoltageProtective ConstructionOperating Function Insulation DistancePacking Quantity; Inner Carton (Pcs.) Packing Quantity; Outer Carton (Pcs.)Operate Voltage (@20oC)Release Voltage (at20°C) Rated Operating Current [±10%] (at 20°C)Resistance [±10%] (at 20°C) Rated Operating Power Max. Allowable Voltage (at 20°C 68°F)Contact ArrangementContact ShapeContact Resistance (Initial)Contact MaterialContact Rating (Resistive Load)Max. Switching Power (Resistive Load) Max. Switching VoltageMax. Switching CurrentMin. Switching Load (Reference Value) Insulation Resistance (Initial)Dielectric Strength (Initial): Between Open ContactsDielectric Strength (Initial): Between Contact and CoilSurge Withstand Voltage (Initial): Between Contact and CoilOperate Time (Initial) (At 20oC)Release Time (Initial) (at 20°C) Hock Resistance (Functional)Hock Resistance (Destructive)Vibration Resistance (Functional) Vibration Resistance (Destructive)Mechanical LifeConditionsWeight (Typ.)
Tab terminal (TMP type) PCB side three terminals (includes one dummy terminal)
High sensitive type
Class F insulation
48 V DC
Flux-resistant
Single side stable
[Between contact and coil]
Clearance: Min. 8 mm, Creepage: Min. 9.5 mm
100
500
Max. 75% V of Rated coil voltage (initial)
Min. 5% V of Rated coil voltage (initial)
4.2 mA
11,520 Ω
200 mW
145% V of Rated coil voltage
1 Form A
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 277 V AC
4,432 VA
277 V AC
16 A
100 mA 5 V DC
Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min. (detection current: 10 mA)
4,000 Vrms for 1 min. (detection current: 10 mA)
10,000 V
Max. 20 ms (at rated coil voltage, without bounce)
Max. 25 ms (at rated coil voltage, without bounce, with diode)
Min. 200 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 2x106 ope. (at 180 times/min.)
Ambient temperature: -40 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 17 g
Tab terminal (TMP type) PCB side three terminals (includes one dummy terminal)
High sensitive type
Class F insulation
24 V DC
Flux-resistant
Single side stable
[Between contact and coil]
Clearance: Min. 8 mm, Creepage: Min. 9.5 mm
100
500
Max. 75% V of Rated coil voltage (initial)
Min. 5% V of Rated coil voltage (initial)
8.3 mA
2,880 Ω
200 mW
145% V of Rated coil voltage
1 Form A
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 277 V AC
4,432 VA
277 V AC
16 A
100 mA 5 V DC
Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min. (detection current: 10 mA)
4,000 Vrms for 1 min. (detection current: 10 mA)
10,000 V
Max. 20 ms (at rated coil voltage, without bounce)
Max. 25 ms (at rated coil voltage, without bounce, with diode)
Min. 200 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 2x106 ope. (at 180 times/min.)
Ambient temperature: -40 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 17 g
Tab terminal (TMP type) PCB side three terminals
High sensitive type
Class B insulation
6 V DC
Flux-resistant
Single side stable
[Between contact and coil]
Clearance: Min. 8 mm, Creepage: Min. 9.5 mm
100
500
Max. 75% V of Rated coil voltage (initial)
Min. 5% V of Rated coil voltage (initial)
33.3 mA
180 Ω
200 mW
145% V of Rated coil voltage
1 Form A
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 277 V AC
4,432 VA
277 V AC
16 A
100 mA 5 V DC
Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min. (detection current: 10 mA)
4,000 Vrms for 1 min. (detection current: 10 mA)
10,000 V
Max. 20 ms (at rated coil voltage, without bounce)
Max. 25 ms (at rated coil voltage, without bounce, with diode)
Min. 200 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 2x106 ope. (at 180 times/min.)
Ambient temperature: -40 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 17 g
Tab terminal (TMP type) PCB side three terminals
High sensitive type
Class B insulation
12 V DC
Flux-resistant
Single side stable
[Between contact and coil]
Clearance: Min. 8 mm, Creepage: Min. 9.5 mm
100
500
Max. 75% V of Rated coil voltage (initial)
Min. 5% V of Rated coil voltage (initial)
16.7 mA
720 Ω
200 mW
145% V of Rated coil voltage
1 Form A
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 277 V AC
4,432 VA
277 V AC
16 A
100 mA 5 V DC
Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min. (detection current: 10 mA)
4,000 Vrms for 1 min. (detection current: 10 mA)
10,000 V
Max. 20 ms (at rated coil voltage, without bounce)
Max. 25 ms (at rated coil voltage, without bounce, with diode)
Min. 200 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 2x106 ope. (at 180 times/min.)
Ambient temperature: -40 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 17 g
Tab terminal (TMP type) PCB side three terminals
High sensitive type
Class B insulation
48 V DC
Flux-resistant
Single side stable
[Between contact and coil]
Clearance: Min. 8 mm, Creepage: Min. 9.5 mm
100
500
Max. 75% V of Rated coil voltage (initial)
Min. 5% V of Rated coil voltage (initial)
4.2 mA
11,520 Ω
200 mW
145% V of Rated coil voltage
1 Form A
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 277 V AC
4,432 VA
277 V AC
16 A
100 mA 5 V DC
Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min. (detection current: 10 mA)
4,000 Vrms for 1 min. (detection current: 10 mA)
10,000 V
Max. 20 ms (at rated coil voltage, without bounce)
Max. 25 ms (at rated coil voltage, without bounce, with diode)
Min. 200 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 2x106 ope. (at 180 times/min.)
Ambient temperature: -40 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 17 g
Tab terminal (TMP type) PCB side three terminals
High sensitive type
Class F insulation
5 V DC
Flux-resistant
Single side stable
[Between contact and coil]
Clearance: Min. 8 mm, Creepage: Min. 9.5 mm
100
500
Max. 75% V of Rated coil voltage (initial)
Min. 5% V of Rated coil voltage (initial)
40 mA
125 Ω
200 mW
145% V of Rated coil voltage
1 Form A
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 277 V AC
4,432 VA
277 V AC
16 A
100 mA 5 V DC
Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min. (detection current: 10 mA)
4,000 Vrms for 1 min. (detection current: 10 mA)
10,000 V
Max. 20 ms (at rated coil voltage, without bounce)
Max. 25 ms (at rated coil voltage, without bounce, with diode)
Min. 200 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 2x106 ope. (at 180 times/min.)
Ambient temperature: -40 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 17 g
Tab terminal (TMP type) PCB side three terminals
High sensitive type
Class F insulation
6 V DC
Flux-resistant
Single side stable
[Between contact and coil]
Clearance: Min. 8 mm, Creepage: Min. 9.5 mm
100
500
Max. 75% V of Rated coil voltage (initial)
Min. 5% V of Rated coil voltage (initial)
33.3 mA
180 Ω
200 mW
145% V of Rated coil voltage
1 Form A
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 277 V AC
4,432 VA
277 V AC
16 A
100 mA 5 V DC
Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min. (detection current: 10 mA)
4,000 Vrms for 1 min. (detection current: 10 mA)
10,000 V
Max. 20 ms (at rated coil voltage, without bounce)
Max. 25 ms (at rated coil voltage, without bounce, with diode)
Min. 200 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 2x106 ope. (at 180 times/min.)
Ambient temperature: -40 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 17 g
Tab terminal (TMP type) PCB side three terminals
High sensitive type
Class F insulation
12 V DC
Flux-resistant
Single side stable
[Between contact and coil]
Clearance: Min. 8 mm, Creepage: Min. 9.5 mm
100
500
Max. 75% V of Rated coil voltage (initial)
Min. 5% V of Rated coil voltage (initial)
16.7 mA
720 Ω
200 mW
145% V of Rated coil voltage
1 Form A
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 277 V AC
4,432 VA
277 V AC
16 A
100 mA 5 V DC
Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min. (detection current: 10 mA)
4,000 Vrms for 1 min. (detection current: 10 mA)
10,000 V
Max. 20 ms (at rated coil voltage, without bounce)
Max. 25 ms (at rated coil voltage, without bounce, with diode)
Min. 200 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 2x106 ope. (at 180 times/min.)
Ambient temperature: -40 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 17 g
Tab terminal (TMP type) PCB side three terminals
High sensitive type
Class F insulation
48 V DC
Flux-resistant
Single side stable
[Between contact and coil]
Clearance: Min. 8 mm, Creepage: Min. 9.5 mm
100
500
Max. 75% V of Rated coil voltage (initial)
Min. 5% V of Rated coil voltage (initial)
4.2 mA
11,520 Ω
200 mW
145% V of Rated coil voltage
1 Form A
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 277 V AC
4,432 VA
277 V AC
16 A
100 mA 5 V DC
Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min. (detection current: 10 mA)
4,000 Vrms for 1 min. (detection current: 10 mA)
10,000 V
Max. 20 ms (at rated coil voltage, without bounce)
Max. 25 ms (at rated coil voltage, without bounce, with diode)
Min. 200 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 2x106 ope. (at 180 times/min.)
Ambient temperature: -40 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 17 g
Tab terminal (TMP type) PCB side four terminals
High sensitive type
Class B insulation
9 V DC
Flux-resistant
Single side stable
[Between contact and coil]
Clearance: Min. 8 mm, Creepage: Min. 9.5 mm
100
500
Max. 75% V of Rated coil voltage (initial)
Min. 5% V of Rated coil voltage (initial)
22.2 mA
405 Ω
200 mW
145% V of Rated coil voltage
1 Form A
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 277 V AC
4,432 VA
277 V AC
16 A
100 mA 5 V DC
Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min. (detection current: 10 mA)
4,000 Vrms for 1 min. (detection current: 10 mA)
10,000 V
Max. 20 ms (at rated coil voltage, without bounce)
Max. 25 ms (at rated coil voltage, without bounce, with diode)
Min. 200 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 2x106 ope. (at 180 times/min.)
Ambient temperature: -40 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 17 g