Specifications
| Item | Performance characteristics |
|---|---|
| Protective Construction | Sealed |
| Terminal Type | Plug-in terminal |
| Relay Shape | Slim type |
| Rated Coil Voltage | 48 V DC |
| Rated Operating Power | 360 mW |
| Contact Arrangement | 2 Form C |
| Operating Function | Single side stable |
| Accessories | Socket and terminal are available. |
| Packing Quantity; Inner Carton (Pcs.) | 20 |
| Packing Quantity; Outer Carton (Pcs.) | 200 |
| Operate Voltage (@20oC) | Max. 80% V of rated coil voltage (Initial) |
| Release Voltage (at20°C) | Min. 10% V of rated coil voltage (Initial) |
| Rated Operating Current [±10%] (at 20°C) | 7.5 mA |
| Resistance [±10%] (at 20°C) | 6,400 Ω |
| Max. Allowable Voltage | 135% V of rated coil voltage (at 50℃) |
| Contact Shape | Twin |
| Contact Resistance (Initial) | Max. 50 mΩ (by voltage drop 6 V DC 1 A) |
| Contact Material | Au-clad AgNi type |
| Contact Rating (Resistive Load) | 3 A 250 V AC, 5 A 30 V DC |
| Max. Switching Power (Resistive Load) | 750 VA, 150 W |
| Max. Switching Voltage | 250 V AC, 220 V DC |
| Max. Switching Current | 3 A (AC), 5 A (DC) |
| Min. Switching Load (Reference Value) | 100 μA 1 V DC |
| Insulation Resistance (Initial) | Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
| Dielectric Strength (Initial): Between Open Contacts | 1,000 Vrms for 1 min (detection current: 10 mA) |
| Dielectric Strength (Initial): Between Contact Sets | 1,000 Vrms for 1 min (detection current: 10 mA) |
| Dielectric Strength (Initial): Between Contact and Coil | 2,000 Vrms for 1 min (detection current: 10 mA) |
| Operate Time (Initial) (At 20oC) | Max. 20 ms at rated coil voltage (without bounce) |
| Release Time (Initial) (at 20°C) | Max. 10 ms at rated coil voltage (without bounce, without diode) |
| Hock Resistance (Functional) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs) |
| Hock Resistance (Destructive) | 980 m/s2 (half-sine shock pulse: 6 ms) |
| Vibration Resistance (Functional) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs) |
| Vibration Resistance (Destructive) | 10 to 55 Hz (at double amplitude of 2 mm) |
| Mechanical Life | Min. 50x106 ope. (switching frequency: at 180 times/min) |
| Conditions | Ambient temperature: -40 to +70℃ Humidity: 5 to 85% RH (Avoid icing and condensation) |
| Weight (Typ.) | Approx. 16 g |
| Resistive Load | [switching frequency: 20 times/min] Min. 500x103 ope. 5 A 30 V DC Min. 100x103 ope. 3 A 250 V AC |