| | 5 V DC | 1 Form A | Twin | Sealed | Single side stable | PC board terminal | Slim type | [Between contact and coil] Clearance: Min. 5.29 mm, Creepage: Min. 5.35 mm | Sockets are available. | Tube package | 25 | 1,000 | Max. 70% V of rated coil voltage (Initial) | Min. 5% V of rated coil voltage (Initial) | 22 mA | 227 Ω | 110 mW | 120% V of rated coil voltage | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | AgNi type + Au | 1,250 VA, 150 W | 5 A 250 V AC, 5 A 30 V DC | 250 V AC, 110 V DC (0.4 A) | 5 A (AC, DC) | 100 µA 100 mV DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 3,000 Vrms for 1 min (detection current: 10 mA) | 6,000 V | Max. 5 ms at rated coil voltage (without bounce, without diode) | Max. 10 ms at rated coil voltage (without bounce) | 147 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2.5 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3.5 mm) | Ambient temperature: -40 to +90°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Min. 20x106 ope. (switching frequency: at 180 times/min) | Approx. 3 g | [switching frequency: 20 times/min] Min. 100x103 ope. 3 A 250 V AC Min. 100x103 ope. 3 A 30 V DC
[switching frequency: 6 times/min, ON : OFF = 1 s : 9 s] Min. 50x103 ope. 5 A 250 V AC
[switching frequency: 20 times/min] Min. 50x103 ope. 5 A 30 V DC | [switching frequency: 6 times/min, ON : OFF = 1 s : 9 s] Min. 100x103 ope. 2 A 250 V AC (cosφ = 0.4) |
| | 9 V DC | 1 Form A | Twin | Sealed | Single side stable | PC board terminal | Slim type | [Between contact and coil] Clearance: Min. 5.29 mm, Creepage: Min. 5.35 mm | Sockets are available. | Tube package | 25 | 1,000 | Max. 70% V of rated coil voltage (Initial) | Min. 5% V of rated coil voltage (Initial) | 12.2 mA | 736 Ω | 110 mW | 120% V of rated coil voltage | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | AgNi type + Au | 1,250 VA, 150 W | 5 A 250 V AC, 5 A 30 V DC | 250 V AC, 110 V DC (0.4 A) | 5 A (AC, DC) | 100 µA 100 mV DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 3,000 Vrms for 1 min (detection current: 10 mA) | 6,000 V | Max. 5 ms at rated coil voltage (without bounce, without diode) | Max. 10 ms at rated coil voltage (without bounce) | 147 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2.5 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3.5 mm) | Ambient temperature: -40 to +90°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Min. 20x106 ope. (switching frequency: at 180 times/min) | Approx. 3 g | [switching frequency: 20 times/min] Min. 100x103 ope. 3 A 250 V AC Min. 100x103 ope. 3 A 30 V DC
[switching frequency: 6 times/min, ON : OFF = 1 s : 9 s] Min. 50x103 ope. 5 A 250 V AC
[switching frequency: 20 times/min] Min. 50x103 ope. 5 A 30 V DC | [switching frequency: 6 times/min, ON : OFF = 1 s : 9 s] Min. 100x103 ope. 2 A 250 V AC (cosφ = 0.4) |
| | 24 V DC | 1 Form A | Twin | Sealed | Single side stable | PC board terminal | Slim type | [Between contact and coil] Clearance: Min. 5.29 mm, Creepage: Min. 5.35 mm | Sockets are available. | Tube package | 25 | 1,000 | Max. 70% V of rated coil voltage (Initial) | Min. 5% V of rated coil voltage (Initial) | 4.6 mA | 5,236 Ω | 110 mW | 120% V of rated coil voltage | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | AgNi type + Au | 1,250 VA, 150 W | 5 A 250 V AC, 5 A 30 V DC | 250 V AC, 110 V DC (0.4 A) | 5 A (AC, DC) | 100 µA 100 mV DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 3,000 Vrms for 1 min (detection current: 10 mA) | 6,000 V | Max. 5 ms at rated coil voltage (without bounce, without diode) | Max. 10 ms at rated coil voltage (without bounce) | 147 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2.5 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3.5 mm) | Ambient temperature: -40 to +90°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Min. 20x106 ope. (switching frequency: at 180 times/min) | Approx. 3 g | [switching frequency: 20 times/min] Min. 100x103 ope. 3 A 250 V AC Min. 100x103 ope. 3 A 30 V DC
[switching frequency: 6 times/min, ON : OFF = 1 s : 9 s] Min. 50x103 ope. 5 A 250 V AC
[switching frequency: 20 times/min] Min. 50x103 ope. 5 A 30 V DC | [switching frequency: 6 times/min, ON : OFF = 1 s : 9 s] Min. 100x103 ope. 2 A 250 V AC (cosφ = 0.4) |
| | 4.5 V DC | 1 Form A | Twin | Sealed | Single side stable | PC board terminal | Slim type | [Between contact and coil] Clearance: Min. 5.29 mm, Creepage: Min. 5.35 mm | Sockets are available. | Tube package | 25 | 1,000 | Max. 70% V of rated coil voltage (Initial) | Min. 5% V of rated coil voltage (Initial) | 24.4 mA | 184 Ω | 110 mW | 120% V of rated coil voltage | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | AgNi type + Au | 1,250 VA, 150 W | 5 A 250 V AC, 5 A 30 V DC | 250 V AC, 110 V DC (0.4 A) | 5 A (AC, DC) | 100 µA 100 mV DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 3,000 Vrms for 1 min (detection current: 10 mA) | 6,000 V | Max. 5 ms at rated coil voltage (without bounce, without diode) | Max. 10 ms at rated coil voltage (without bounce) | 147 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2.5 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3.5 mm) | Ambient temperature: -40 to +90°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Min. 20x106 ope. (switching frequency: at 180 times/min) | Approx. 3 g | [switching frequency: 20 times/min] Min. 100x103 ope. 3 A 250 V AC Min. 100x103 ope. 3 A 30 V DC
[switching frequency: 6 times/min, ON : OFF = 1 s : 9 s] Min. 50x103 ope. 5 A 250 V AC
[switching frequency: 20 times/min] Min. 50x103 ope. 5 A 30 V DC | [switching frequency: 6 times/min, ON : OFF = 1 s : 9 s] Min. 100x103 ope. 2 A 250 V AC (cosφ = 0.4) |
| | 6 V DC | 1 Form A | Twin | Sealed | Single side stable | PC board terminal | Slim type | [Between contact and coil] Clearance: Min. 5.29 mm, Creepage: Min. 5.35 mm | Sockets are available. | Tube package | 25 | 1,000 | Max. 70% V of rated coil voltage (Initial) | Min. 5% V of rated coil voltage (Initial) | 18.3 mA | 327 Ω | 110 mW | 120% V of rated coil voltage | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | AgNi type + Au | 1,250 VA, 150 W | 5 A 250 V AC, 5 A 30 V DC | 250 V AC, 110 V DC (0.4 A) | 5 A (AC, DC) | 100 µA 100 mV DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 3,000 Vrms for 1 min (detection current: 10 mA) | 6,000 V | Max. 5 ms at rated coil voltage (without bounce, without diode) | Max. 10 ms at rated coil voltage (without bounce) | 147 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2.5 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3.5 mm) | Ambient temperature: -40 to +90°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Min. 20x106 ope. (switching frequency: at 180 times/min) | Approx. 3 g | [switching frequency: 20 times/min] Min. 100x103 ope. 3 A 250 V AC Min. 100x103 ope. 3 A 30 V DC
[switching frequency: 6 times/min, ON : OFF = 1 s : 9 s] Min. 50x103 ope. 5 A 250 V AC
[switching frequency: 20 times/min] Min. 50x103 ope. 5 A 30 V DC | [switching frequency: 6 times/min, ON : OFF = 1 s : 9 s] Min. 100x103 ope. 2 A 250 V AC (cosφ = 0.4) |
| | 3 V DC | 1 Form A | Twin | Sealed | Single side stable | PC board terminal | Slim type | [Between contact and coil] Clearance: Min. 5.29 mm, Creepage: Min. 5.35 mm | Sockets are available. | Tube package | 25 | 1,000 | Max. 70% V of rated coil voltage (Initial) | Min. 5% V of rated coil voltage (Initial) | 36.7 mA | 82 Ω | 110 mW | 120% V of rated coil voltage | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | AgNi type + Au | 1,250 VA, 150 W | 5 A 250 V AC, 5 A 30 V DC | 250 V AC, 110 V DC (0.4 A) | 5 A (AC, DC) | 100 µA 100 mV DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 3,000 Vrms for 1 min (detection current: 10 mA) | 6,000 V | Max. 5 ms at rated coil voltage (without bounce, without diode) | Max. 10 ms at rated coil voltage (without bounce) | 147 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2.5 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3.5 mm) | Ambient temperature: -40 to +90°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Min. 20x106 ope. (switching frequency: at 180 times/min) | Approx. 3 g | [switching frequency: 20 times/min] Min. 100x103 ope. 3 A 250 V AC Min. 100x103 ope. 3 A 30 V DC
[switching frequency: 6 times/min, ON : OFF = 1 s : 9 s] Min. 50x103 ope. 5 A 250 V AC
[switching frequency: 20 times/min] Min. 50x103 ope. 5 A 30 V DC | [switching frequency: 6 times/min, ON : OFF = 1 s : 9 s] Min. 100x103 ope. 2 A 250 V AC (cosφ = 0.4) |
| | 12 V DC | 1 Form A | Twin | Sealed | Single side stable | PC board terminal | Slim type | [Between contact and coil] Clearance: Min. 5.29 mm, Creepage: Min. 5.35 mm | Sockets are available. | Tube package | 25 | 1,000 | Max. 70% V of rated coil voltage (Initial) | Min. 5% V of rated coil voltage (Initial) | 9.2 mA | 1,309 Ω | 110 mW | 120% V of rated coil voltage | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | AgNi type + Au | 1,250 VA, 150 W | 5 A 250 V AC, 5 A 30 V DC | 250 V AC, 110 V DC (0.4 A) | 5 A (AC, DC) | 100 µA 100 mV DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 3,000 Vrms for 1 min (detection current: 10 mA) | 6,000 V | Max. 5 ms at rated coil voltage (without bounce, without diode) | Max. 10 ms at rated coil voltage (without bounce) | 147 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2.5 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3.5 mm) | Ambient temperature: -40 to +90°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Min. 20x106 ope. (switching frequency: at 180 times/min) | Approx. 3 g | [switching frequency: 20 times/min] Min. 100x103 ope. 3 A 250 V AC Min. 100x103 ope. 3 A 30 V DC
[switching frequency: 6 times/min, ON : OFF = 1 s : 9 s] Min. 50x103 ope. 5 A 250 V AC
[switching frequency: 20 times/min] Min. 50x103 ope. 5 A 30 V DC | [switching frequency: 6 times/min, ON : OFF = 1 s : 9 s] Min. 100x103 ope. 2 A 250 V AC (cosφ = 0.4) |
| | 18 V DC | 1 Form A | Twin | Sealed | Single side stable | PC board terminal | Slim type | [Between contact and coil] Clearance: Min. 5.29 mm, Creepage: Min. 5.35 mm | Sockets are available. | Tube package | 25 | 1,000 | Max. 70% V of rated coil voltage (Initial) | Min. 5% V of rated coil voltage (Initial) | 6.1 mA | 2,945 Ω | 110 mW | 120% V of rated coil voltage | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | AgNi type + Au | 1,250 VA, 150 W | 5 A 250 V AC, 5 A 30 V DC | 250 V AC, 110 V DC (0.4 A) | 5 A (AC, DC) | 100 µA 100 mV DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 3,000 Vrms for 1 min (detection current: 10 mA) | 6,000 V | Max. 5 ms at rated coil voltage (without bounce, without diode) | Max. 10 ms at rated coil voltage (without bounce) | 147 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2.5 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3.5 mm) | Ambient temperature: -40 to +90°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Min. 20x106 ope. (switching frequency: at 180 times/min) | Approx. 3 g | [switching frequency: 20 times/min] Min. 100x103 ope. 3 A 250 V AC Min. 100x103 ope. 3 A 30 V DC
[switching frequency: 6 times/min, ON : OFF = 1 s : 9 s] Min. 50x103 ope. 5 A 250 V AC
[switching frequency: 20 times/min] Min. 50x103 ope. 5 A 30 V DC | [switching frequency: 6 times/min, ON : OFF = 1 s : 9 s] Min. 100x103 ope. 2 A 250 V AC (cosφ = 0.4) |