Specifications
| Item | Performance characteristics | 
|---|---|
| Rated Coil Voltage | 18 V DC | 
| Contact Arrangement | 1 Form C | 
| Contact Material | AgNi type | 
| Protective Construction | Sealed | 
| Operating Function | Single side stable | 
| Terminal Type | PC board terminal | 
| Relay Shape | Slim type | 
| Packing Quantity | Tube package | 
| Packing Quantity; Inner Carton (Pcs.) | 20 | 
| Packing Quantity; Outer Carton (Pcs.) | 1,000 | 
| Operate Voltage (@20oC) | Max. 70% V of rated coil voltage (Initial) | 
| Release Voltage (at20°C) | Min. 5% V of rated coil voltage (Initial) | 
| Rated Operating Current [±10%] (at 20°C) | 9.4 mA | 
| Resistance [±10%] (at 20°C) | 1,906 Ω | 
| Rated Operating Power | 170 mW | 
| Max. Allowable Voltage (at 20°C 68°F) | 120% V of rated coil voltage | 
| Contact Shape | Single | 
| Contact Resistance (Initial) | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | 
| Contact Rating (Resistive Load) | 6 A 250 V AC | 
| Max. Switching Power (Resistive Load) | 1,500 VA | 
| Max. Switching Voltage | 250 V AC | 
| Max. Switching Current | 6 A (AC) | 
| Min. Switching Load (Reference Value) | 100 mA 5 V DC | 
| Insulation Resistance (Initial) | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 
| Dielectric Strength (Initial): Between Open Contacts | 1,000 Vrms for 1 min (detection current: 10 mA) | 
| Dielectric Strength (Initial): Between Contact and Coil | 4,000 Vrms for 1 min (detection current: 10 mA) | 
| Surge Withstand Voltage (Initial): Between Contact and Coil | 6,000 V | 
| Operate Time (Initial) (At 20oC) | Max. 8 ms at rated coil voltage (without bounce) | 
| Release Time (Initial) (at 20°C) | Max. 4 ms at rated coil voltage (without bounce, without diode) | 
| Hock Resistance (Functional) | 49 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs) | 
| Hock Resistance (Destructive) | 980 m/s2 (half-sine shock pulse: 11 ms) | 
| Vibration Resistance (Functional) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs) | 
| Vibration Resistance (Destructive) | 10 to 55 Hz (at double amplitude of 1.5 mm) | 
| Mechanical Life | Min. 5x106 ope. (switching frequency: at 180 times/min) | 
| Conditions | Ambient temperature: -40 to +85℃ (Allowable temperature is from -40 to +60℃ at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation)  | 
| Weight (Typ.) | Approx. 5 g | 
| Resistive Load | [switching frequency: 6 times/min] N.O.: Min. 50x103 ope. 6 A 250 V AC N.C.: Min. 30x103 ope. 6 A 250 V AC  | 