Part Number List

Results 28
Models table for series JT-N Series Relay
Part No.DatasheetProtective ConstructionTerminal TypeRated Coil VoltageContact ArrangementOperating Function Pick-Up VoltageDrop-Out VoltageRated Operating Power Max. Switching VoltageMax. Switching CurrentContact MaterialCoil Insulation ClassDielectric Strength (Initial): Between Contact and CoilOperate Voltage (@20oC)Release Voltage (at20°C) Rated Operating Current [±10%] (at 20°C)Resistance [±10%] (at 20°C) Max. Allowable Voltage (at 20°C 68°F)Contact ShapeContact Resistance (Initial)Contact Rating (Resistive Load)Max. Switching Power (Resistive Load) Min. Switching Load (Reference Value) Insulation Resistance (Initial)Dielectric Strength (Initial): Between Open ContactsOperate Time (Initial) (At 20oC)Release Time (Initial) (at 20°C) Hock Resistance (Functional)Hock Resistance (Destructive)Vibration Resistance (Functional) Vibration Resistance (Destructive)Mechanical LifeElectrical LifeConditionsWeight (Typ.)
Sealed
Tab terminal (TMP type)
6 V DC
1 Form A
Single side stable
75%V or less of Nominal coil voltage (Initial)
10%V or more of Nominal coil voltage (Initial)
800 mW
277 V AC
30 A
AgSnO2 type
Class F insulation
2,500 Vrms for 1 min. (detection current: 10 mA)
Max. 75% V of rated coil voltage (initial)
Min. 10% V of rataed coil voltage (initial)
133.3 mA
45 Ω
120% V of rated coil voltage
Single
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
20 A 277 V AC
8,310 VA (30 A 277 V AC)
100 mA 5 V DC
Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,200 Vrms for 1 min. (detection current: 10 mA)
Max. 20 ms (at rated coil voltage, without bounce)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 1x107 ope.
Min. 1x105 ope. (20 A 277 V AC at resistive load) (at 20 times/min.)
Ambient temperature: -55 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 30 g
Sealed
Tab terminal (TMP type)
9 V DC
1 Form A
Single side stable
75%V or less of Nominal coil voltage (Initial)
10%V or more of Nominal coil voltage (Initial)
800 mW
277 V AC
30 A
AgSnO2 type
Class F insulation
2,500 Vrms for 1 min. (detection current: 10 mA)
Max. 75% V of rated coil voltage (initial)
Min. 10% V of rataed coil voltage (initial)
89.1 mA
101 Ω
120% V of rated coil voltage
Single
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
20 A 277 V AC
8,310 VA (30 A 277 V AC)
100 mA 5 V DC
Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,200 Vrms for 1 min. (detection current: 10 mA)
Max. 20 ms (at rated coil voltage, without bounce)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 1x107 ope.
Min. 1x105 ope. (20 A 277 V AC at resistive load) (at 20 times/min.)
Ambient temperature: -55 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 30 g
Sealed
Tab terminal (TMP type)
15 V DC
1 Form A
Single side stable
75%V or less of Nominal coil voltage (Initial)
10%V or more of Nominal coil voltage (Initial)
800 mW
277 V AC
30 A
AgSnO2 type
Class F insulation
2,500 Vrms for 1 min. (detection current: 10 mA)
Max. 75% V of rated coil voltage (initial)
Min. 10% V of rataed coil voltage (initial)
53.4 mA
281 Ω
120% V of rated coil voltage
Single
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
20 A 277 V AC
8,310 VA (30 A 277 V AC)
100 mA 5 V DC
Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,200 Vrms for 1 min. (detection current: 10 mA)
Max. 20 ms (at rated coil voltage, without bounce)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 1x107 ope.
Min. 1x105 ope. (20 A 277 V AC at resistive load) (at 20 times/min.)
Ambient temperature: -55 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 30 g
Sealed
Tab terminal (TMP type)
18 V DC
1 Form A
Single side stable
75%V or less of Nominal coil voltage (Initial)
10%V or more of Nominal coil voltage (Initial)
800 mW
277 V AC
30 A
AgSnO2 type
Class F insulation
2,500 Vrms for 1 min. (detection current: 10 mA)
Max. 75% V of rated coil voltage (initial)
Min. 10% V of rataed coil voltage (initial)
44.4 mA
405 Ω
120% V of rated coil voltage
Single
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
20 A 277 V AC
8,310 VA (30 A 277 V AC)
100 mA 5 V DC
Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,200 Vrms for 1 min. (detection current: 10 mA)
Max. 20 ms (at rated coil voltage, without bounce)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 1x107 ope.
Min. 1x105 ope. (20 A 277 V AC at resistive load) (at 20 times/min.)
Ambient temperature: -55 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 30 g
Sealed
Tab terminal (TMP type)
5 V DC
1 Form A
Single side stable
75%V or less of Nominal coil voltage (Initial)
10%V or more of Nominal coil voltage (Initial)
800 mW
277 V AC
30 A
AgSnO2 type
Class F insulation
2,500 Vrms for 1 min. (detection current: 10 mA)
Max. 75% V of rated coil voltage (initial)
Min. 10% V of rataed coil voltage (initial)
161.3 mA
31 Ω
120% V of rated coil voltage
Single
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
20 A 277 V AC
8,310 VA (30 A 277 V AC)
100 mA 5 V DC
Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,200 Vrms for 1 min. (detection current: 10 mA)
Max. 20 ms (at rated coil voltage, without bounce)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 1x107 ope.
Min. 1x105 ope. (20 A 277 V AC at resistive load) (at 20 times/min.)
Ambient temperature: -55 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 30 g
Sealed
Tab terminal (TMP type)
6 V DC
1 Form C
Single side stable
75%V or less of Nominal coil voltage (Initial)
10%V or more of Nominal coil voltage (Initial)
800 mW
277 V AC
N.C.: 10 A, N.O.: 20 A
AgSnO2 type
Class F insulation
2,500 Vrms for 1 min. (detection current: 10 mA)
Max. 75% V of rated coil voltage (initial)
Min. 10% V of rataed coil voltage (initial)
133.3 mA
45 Ω
120% V of rated coil voltage
Single
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
N.C. : 10 A 277 V AC, N.O. : 20 A 277 V AC
N.C.: 2,770 VA, N.O.: 5,540 VA
100 mA 5 V DC
Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,200 Vrms for 1 min. (detection current: 10 mA)
Max. 20 ms (at rated coil voltage, without bounce)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 1x107 ope.
N.O.: Min. 1x105 ope. (20 A 277 V AC at resistive load)
N.C.: Min. 1x105 ope. (10A 277V AC at resistive load)
(at 20 times/min.)
Ambient temperature: -55 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 30 g
Sealed
Tab terminal (TMP type)
9 V DC
1 Form C
Single side stable
75%V or less of Nominal coil voltage (Initial)
10%V or more of Nominal coil voltage (Initial)
800 mW
277 V AC
N.C.: 10 A, N.O.: 20 A
AgSnO2 type
Class F insulation
2,500 Vrms for 1 min. (detection current: 10 mA)
Max. 75% V of rated coil voltage (initial)
Min. 10% V of rataed coil voltage (initial)
89.1 mA
101 Ω
120% V of rated coil voltage
Single
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
N.C. : 10 A 277 V AC, N.O. : 20 A 277 V AC
N.C.: 2,770 VA, N.O.: 5,540 VA
100 mA 5 V DC
Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,200 Vrms for 1 min. (detection current: 10 mA)
Max. 20 ms (at rated coil voltage, without bounce)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 1x107 ope.
N.O.: Min. 1x105 ope. (20 A 277 V AC at resistive load)
N.C.: Min. 1x105 ope. (10A 277V AC at resistive load)
(at 20 times/min.)
Ambient temperature: -55 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 30 g
Sealed
Tab terminal (TMP type)
18 V DC
1 Form C
Single side stable
75%V or less of Nominal coil voltage (Initial)
10%V or more of Nominal coil voltage (Initial)
800 mW
277 V AC
N.C.: 10 A, N.O.: 20 A
AgSnO2 type
Class F insulation
2,500 Vrms for 1 min. (detection current: 10 mA)
Max. 75% V of rated coil voltage (initial)
Min. 10% V of rataed coil voltage (initial)
44.4 mA
405 Ω
120% V of rated coil voltage
Single
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
N.C. : 10 A 277 V AC, N.O. : 20 A 277 V AC
N.C.: 2,770 VA, N.O.: 5,540 VA
100 mA 5 V DC
Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,200 Vrms for 1 min. (detection current: 10 mA)
Max. 20 ms (at rated coil voltage, without bounce)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 1x107 ope.
N.O.: Min. 1x105 ope. (20 A 277 V AC at resistive load)
N.C.: Min. 1x105 ope. (10A 277V AC at resistive load)
(at 20 times/min.)
Ambient temperature: -55 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 30 g
Sealed
PC board terminal
12 V DC
1 Form A
Single side stable
75%V or less of Nominal coil voltage (Initial)
10%V or more of Nominal coil voltage (Initial)
800 mW
277 V AC
30 A
AgSnO2 type
Class F insulation
2,500 Vrms for 1 min. (detection current: 10 mA)
Max. 75% V of rated coil voltage (initial)
Min. 10% V of rataed coil voltage (initial)
66.6 mA
180 Ω
120% V of rated coil voltage
Single
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
20 A 277 V AC
8,310 VA (30 A 277 V AC)
100 mA 5 V DC
Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,200 Vrms for 1 min. (detection current: 10 mA)
Max. 20 ms (at rated coil voltage, without bounce)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 1x107 ope.
Min. 1x105 ope. (20 A 277 V AC at resistive load) (at 20 times/min.)
Ambient temperature: -55 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 25 g
Sealed
PC board terminal
15 V DC
1 Form A
Single side stable
75%V or less of Nominal coil voltage (Initial)
10%V or more of Nominal coil voltage (Initial)
800 mW
277 V AC
30 A
AgSnO2 type
Class F insulation
2,500 Vrms for 1 min. (detection current: 10 mA)
Max. 75% V of rated coil voltage (initial)
Min. 10% V of rataed coil voltage (initial)
53.4 mA
281 Ω
120% V of rated coil voltage
Single
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
20 A 277 V AC
8,310 VA (30 A 277 V AC)
100 mA 5 V DC
Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,200 Vrms for 1 min. (detection current: 10 mA)
Max. 20 ms (at rated coil voltage, without bounce)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 1x107 ope.
Min. 1x105 ope. (20 A 277 V AC at resistive load) (at 20 times/min.)
Ambient temperature: -55 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 25 g