Part Number List

Results 4
Models table for series HE-N Relays
Part No.DatasheetContact TypeRated Coil VoltageProtective ConstructionOperating Function Terminal TypeInsulation DistanceContact GapPacking Quantity; Inner Carton (Pcs.) Packing Quantity; Outer Carton (Pcs.)Operate Voltage (@20oC)Release Voltage (at20°C) Rated Operating Current [±10%] (at 20°C)Resistance [±10%] (at 20°C) Rated Operating Power Max. Allowable Voltage Contact ArrangementContact ShapeContact Resistance (Initial)Contact MaterialContact Rating (Resistive Load)Max. Switching Power (Resistive Load) Max. Switching VoltageMax. Switching CurrentMin. Switching Load (Reference Value) Insulation Resistance (Initial)Dielectric Strength (Initial): Between Open ContactsDielectric Strength (Initial): Between Contact and CoilSurge Withstand Voltage (Initial): Between Contact and CoilCoil Holding VoltageOperate Time (Initial) (At 20oC)Release Time (Initial) (at 20°C) Hock Resistance (Functional)Hock Resistance (Destructive)Vibration Resistance (Functional) Vibration Resistance (Destructive)Mechanical LifeConditionsWeight (Typ.)Resistive Load
120 A
9V DC
Flux-resistant
Single side stable
PC board terminal (wide blade)
Min. 10.5 mm (Clearance and Creepage) (Initial)
Min. 3.6 mm (Initial)
10
50
Max. 75% V of Rated coil voltage (initial)
Min. 5% V of Rated coil voltage (initial)
278 mA
32.4 Ω
2,500 mW
110% V of Rated coil voltage (at 55°C)
1 Form A
Single
Max. 10 mΩ (by voltage drop 5 V DC 20 A)
AgNi type
120 A 480 V AC
57,600 VA
800 V AC
120 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
2,000 Vrms for 1 min. (detection current: 10 mA)
5,000 Vrms for 1 min. (detection current: 10 mA)
10,000 V
40 to 100% V (contact carrying current: 120 A, at 20°C)
50 to 60% V (contact carrying current: 120 A, at 85°C)
Max. 30 ms (at rated coil voltage, without bounce)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.0 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 1x106 ope. (at 180 times/min.)
Ambient temperature: -40 to +55°C
(When coil holding voltage is 40 to 100% V of rated voltage.)
Ambient temperature: -40 to +85°C
(When coil holding voltage is 50 to 60% V of rated voltage or storage.)
Humidity: 5 to 85% R.H. (Avoid icing when using at temperatures lower than 0°.)
Approx. 115 g
Min. 1,000 ope. 120 A 480 V AC (at 85°C, ON : OFF = 1 s : 9 s)
Min. 10,000 ope. 55 A 800 V AC (at 85°C, ON : OFF = 1 s : 9 s)
120 A
12 V DC
Flux-resistant
Single side stable
PC board terminal (wide blade)
Min. 10.5 mm (Clearance and Creepage) (Initial)
Min. 3.6 mm (Initial)
10
50
Max. 75% V of Rated coil voltage (initial)
Min. 5% V of Rated coil voltage (initial)
208 mA
57.6 Ω
2,500 mW
110% V of Rated coil voltage (at 55°C)
1 Form A
Single
Max. 10 mΩ (by voltage drop 5 V DC 20 A)
AgNi type
120 A 480 V AC
57,600 VA
800 V AC
120 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
2,000 Vrms for 1 min. (detection current: 10 mA)
5,000 Vrms for 1 min. (detection current: 10 mA)
10,000 V
40 to 100% V (contact carrying current: 120 A, at 20°C)
50 to 60% V (contact carrying current: 120 A, at 85°C)
Max. 30 ms (at rated coil voltage, without bounce)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.0 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 1x106 ope. (at 180 times/min.)
Ambient temperature: -40 to +55°C
(When coil holding voltage is 40 to 100% V of rated voltage.)
Ambient temperature: -40 to +85°C
(When coil holding voltage is 50 to 60% V of rated voltage or storage.)
Humidity: 5 to 85% R.H. (Avoid icing when using at temperatures lower than 0°.)
Approx. 115 g
Min. 1,000 ope. 120 A 480 V AC (at 85°C, ON : OFF = 1 s : 9 s)
Min. 10,000 ope. 55 A 800 V AC (at 85°C, ON : OFF = 1 s : 9 s)
120 A
24 V DC
Flux-resistant
Single side stable
PC board terminal (wide blade)
Min. 10.5 mm (Clearance and Creepage) (Initial)
Min. 3.6 mm (Initial)
10
50
Max. 75% V of Rated coil voltage (initial)
Min. 5% V of Rated coil voltage (initial)
104 mA
230 Ω
2,500 mW
110% V of Rated coil voltage (at 55°C)
1 Form A
Single
Max. 10 mΩ (by voltage drop 5 V DC 20 A)
AgNi type
120 A 480 V AC
57,600 VA
800 V AC
120 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
2,000 Vrms for 1 min. (detection current: 10 mA)
5,000 Vrms for 1 min. (detection current: 10 mA)
10,000 V
40 to 100% V (contact carrying current: 120 A, at 20°C)
50 to 60% V (contact carrying current: 120 A, at 85°C)
Max. 30 ms (at rated coil voltage, without bounce)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.0 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 1x106 ope. (at 180 times/min.)
Ambient temperature: -40 to +55°C
(When coil holding voltage is 40 to 100% V of rated voltage.)
Ambient temperature: -40 to +85°C
(When coil holding voltage is 50 to 60% V of rated voltage or storage.)
Humidity: 5 to 85% R.H. (Avoid icing when using at temperatures lower than 0°.)
Approx. 115 g
Min. 1,000 ope. 120 A 480 V AC (at 85°C, ON : OFF = 1 s : 9 s)
Min. 10,000 ope. 55 A 800 V AC (at 85°C, ON : OFF = 1 s : 9 s)
120 A
6 V DC
Flux-resistant
Single side stable
PC board terminal (wide blade)
Min. 10.5 mm (Clearance and Creepage) (Initial)
Min. 3.6 mm (Initial)
10
50
Max. 75% V of Rated coil voltage (initial)
Min. 5% V of Rated coil voltage (initial)
417 mA
14.4 Ω
2,500 mW
110% V of Rated coil voltage (at 55°C)
1 Form A
Single
Max. 10 mΩ (by voltage drop 5 V DC 20 A)
AgNi type
120 A 480 V AC
57,600 VA
800 V AC
120 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
2,000 Vrms for 1 min. (detection current: 10 mA)
5,000 Vrms for 1 min. (detection current: 10 mA)
10,000 V
40 to 100% V (contact carrying current: 120 A, at 20°C)
50 to 60% V (contact carrying current: 120 A, at 85°C)
Max. 30 ms (at rated coil voltage, without bounce)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.0 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 1x106 ope. (at 180 times/min.)
Ambient temperature: -40 to +55°C
(When coil holding voltage is 40 to 100% V of rated voltage.)
Ambient temperature: -40 to +85°C
(When coil holding voltage is 50 to 60% V of rated voltage or storage.)
Humidity: 5 to 85% R.H. (Avoid icing when using at temperatures lower than 0°.)
Approx. 115 g
Min. 1,000 ope. 120 A 480 V AC (at 85°C, ON : OFF = 1 s : 9 s)
Min. 10,000 ope. 55 A 800 V AC (at 85°C, ON : OFF = 1 s : 9 s)