Specifications
Item | Performance characteristics |
---|---|
Contact Capacity | 200A |
Coil Voltage | 12V DC |
Rated operating power | 6W |
Terminal Type | Lead wire type |
Contact Arrangement | 1 Form A |
Nominal Switching Capacity (Resistive Load) | 200A 400V DC |
Max. Switching Voltage | 1,000V DC |
Minimum (For Reference) | 1A 12V DC |
Accessories | Two dedicated M6 bolts |
Pick-Up Voltage | Max. 75% V of rated coil voltage (initial) (at 20°C) |
Drop-Out Voltage | Min. 8.3% V of rated coil voltage (initial) (at 20°C) |
Expected Life: Mechanical | Min. 200x103 ope. |
Expected Life: Electrical | 60 A 1,000 V DC Min. 103ope. (switching frequency: 6 times/min) (Resistive load) 200 A 400 V DC Min. 3x103ope. (switching frequency: 20 times/min) (Resistive load) |
Breakdown Voltage (Contact-Contact) (Initial) | 2500Vrms |
Breakdown Voltage (Initial) : Between Contact And Coil | 2500Vrms |
Conditions | Ambient temperature: -40° to +80°C (storage: Max. +85°C) Humidity: 5 to 85% RH (Avoid icing and condensation) |
Protective Construction | Sealed capsule |
Operating Function | Single Side Stable Type |
Contact Specification | 200 A |
Contact Material | Copper alloy |
Max. Switching Current | 200A |
Stock check
AEP17012
Latest Videos