Specifications

Specifications table for model AEP52012
ItemPerformance characteristics
Contact Capacity20A
Coil Voltage12V DC
Rated operating power3.9W
Terminal TypeTM type
Contact Arrangement1 Form A
Nominal Switching Capacity (Resistive Load) 20A 400V DC
Max. Switching Voltage1,000V DC
Minimum (For Reference)1A 12V DC
Pick-Up VoltageMax. 75% V of rated coil voltage (initial) (at 20°C)
Drop-Out VoltageMin. 4.17% V of rated coil voltage (initial) (at 20°C)
Expected Life: MechanicalMin. 200x103 ope.
Expected Life: Electrical10 A 1,000 V DC Min. 103ope. (switching frequency: 6 times/min)(Resistive load)
20 A 400 V DC Min. 3x103ope. (switching frequency: 6 times/min)(Resistive load)
Breakdown Voltage (Contact-Contact) (Initial)2500Vrms
Breakdown Voltage (Initial) : Between Contact And Coil2500Vrms
ConditionsAmbient temperature: -40° to +80°C (storage: Max. +85°C)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Protective ConstructionSealed capsule
Operating Function Single Side Stable Type
Contact Specification20 A
Contact MaterialCopper alloy
Max. Switching Current20A

Stock check

Model image for AEP52012