Specifications
Item | Performance characteristics |
---|---|
Coil Voltage | 6V DC |
Contact Arrangement | 2 Form A |
Contact Material | AgNi type |
Nominal Switching Capacity (Resistive Load) | 20 A 800 V DC, 25A 600V DC (at each 1 Form A contact connected in series), 20 A 400 VDC (at 1 Form A contact only) |
Max. Switching Voltage | 1,000V DC |
Max. Switching Current | 25A |
Minimum (For Reference) | 100mA 5V DC |
Rated operating power | 1,920mW |
Pick-Up Voltage | Max. 70% V of rated coil voltage (initial) (at 20°C) |
Drop-Out Voltage | Min. 5% V of rated coil voltage (initial) (at 20°C) |
Expected Life: Mechanical | Min. 106 ope. (switching frequency: at 180 times/min) |
Expected Life: Electrical | Conditions: at 20°C, switching frequency ON : OFF = 1 s : 9 s [Contact connected in series, Resistive load] 20 A 600 V DC Min. 10x103 ope. 20 A 800 V DC Min. 103 ope. 25 A 600 V DC Min. 6x103 ope. [1 Form A contact only, Resistive load] 20 A 300 V DC Min. 10x103 ope. 20 A 400 V DC Min. 103 ope. |
Breakdown Voltage (Contact-Contact) (Initial) | 2000Vrms |
Breakdown Voltage (Initial) : Between Contact And Coil | 5000Vrms |
Conditions | Ambient temperature: -40 to +55°C (When coil holding voltage is 33% to 110% of rated coil voltage) Ambient temperature: -40 to +85°C (When coil holding voltage is 33% to 60% of rated coil voltage) Humidity: 5 to 85% RH (Avoid icing and condensation) |
Protective Construction | Flux-resistant |
Operating Function | Single Side Stable Type |
Terminal Type | PC board through hole terminal |
Stock check
HEV2aN-P-DC6V
Latest Videos
Playlist

Smart Grid Products: LF-G Series Power Relays