Specifications
| Item | Performance characteristics |
|---|---|
| Coil Voltage | 9V DC |
| Contact Arrangement | 2 Form A |
| Contact Material | AgNi type |
| Nominal Switching Capacity (Resistive Load) | 20 A 800 V DC, 25A 600V DC (at each 1 Form A contact connected in series), 20 A 400 VDC (at 1 Form A contact only) |
| Max. Switching Voltage | 1,000V DC |
| Max. Switching Current | 25A |
| Minimum (For Reference) | 100mA 5V DC |
| Rated operating power | 1,920mW |
| Pick-Up Voltage | Max. 70% V of rated coil voltage (initial) (at 20°C) |
| Drop-Out Voltage | Min. 5% V of rated coil voltage (initial) (at 20°C) |
| Expected Life: Mechanical | Min. 106 ope. (switching frequency: at 180 times/min) |
| Expected Life: Electrical | Conditions: at 20°C, switching frequency ON : OFF = 1 s : 9 s [Contact connected in series, Resistive load] 20 A 600 V DC Min. 10x103 ope. 20 A 800 V DC Min. 103 ope. 25 A 600 V DC Min. 6x103 ope. [1 Form A contact only, Resistive load] 20 A 300 V DC Min. 10x103 ope. 20 A 400 V DC Min. 103 ope. |
| Breakdown Voltage (Contact-Contact) (Initial) | 2000Vrms |
| Breakdown Voltage (Initial) : Between Contact And Coil | 5000Vrms |
| Conditions | Ambient temperature: -40 to +55°C (When coil holding voltage is 33% to 110% of rated coil voltage) Ambient temperature: -40 to +85°C (When coil holding voltage is 33% to 60% of rated coil voltage) Humidity: 5 to 85% RH (Avoid icing and condensation) |
| Protective Construction | Flux-resistant |
| Operating Function | Single Side Stable Type |
| Terminal Type | PC board through hole terminal |
Stock check
HEV2aN-P-DC9V
Resources
Filter by:
Showing 1 to 7 of 7 results
Results7
Latest Videos