Specifications

Specifications table for model DE2a-L2-5V
ItemPerformance characteristics
Operating Function 2 coil latching
Rated Coil Voltage5 V DC
Contact Arrangement2 Form A
Protective ConstructionSealed
Terminal TypePC board terminal
Insulation Distance[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
Packing QuantityTube package
Packing Quantity; Inner Carton (Pcs.) 20
Packing Quantity; Outer Carton (Pcs.)500
Set Voltage Max. 70% V of rated coil voltage (Initial)
Reset VoltageMax. 70% V of rated coil voltage (Initial)
Rated Operating Current [±10%] (at 20°C)Set coil: 40 mA
Reset coil: 40 mA
Resistance [±10%] (at 20°C) Set coil: 125 Ω
Reset coil: 125 Ω
Rated Operating Power 200 mW
Max. Allowable Voltage (at 20°C 68°F)130% V of rated coil voltage
Contact ShapeSingle
Contact Resistance (Initial)Max. 30 mΩ (by voltage drop 6 V DC 1 A)
Contact Rating (Resistive Load)8 A 250 V AC, 8 A 30 V DC
Contact MaterialAgSnO2 type
Max. Switching Power (Resistive Load) 2,000 VA (AC), 240 W (DC)
Max. Switching Voltage250 V AC, 30 V DC
Max. Switching Current8 A
Min. Switching Load (Reference Value) 100 mA 5 V DC
Insulation Resistance (Initial)Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric Strength (Initial): Between Open Contacts1,000 Vrms for 1 min (detection current: 10 mA)
Dielectric Strength (Initial): Between Contact and Coil5,000 Vrms for 1 min (detection current: 10 mA)
Surge Withstand Voltage (Initial): Between Contact and Coil12,000 V
Time (Initial) (at 20°C 68°F) (Initial) Max. 10 ms at rated coil voltage (without bounce)
Dielectric Strength (Initial): Between Contact Sets4,000 Vrms for 1 min (detection current: 10 mA)
Reset Time (Initial) (at20°C 68°F) Max. 10 ms at rated coil voltage (without bounce, without diode)
Hock Resistance (Functional)196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
Hock Resistance (Destructive)980 m/s2 (half-sine shock pulse: 6 ms)
Vibration Resistance (Functional)10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs)
Vibration Resistance (Destructive)10 to 55 Hz (at double amplitude of 3 mm)
Mechanical LifeMin. 10x106 ope. (switching frequency: at 300 times/min)
ConditionsAmbient temperature: -40 to +70℃ (Allowable temperature is from -40 to +60℃ at our standard packing condition.)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Weight (Typ.)Approx. 7 g
Resistive Load[switching frequency: 20 times/min]
Min. 100x103 ope. 8 A 250 V AC
Min. 50x103 ope. 8 A 30 V DC

Stock check

DE2a-L2-5V

Latest Videos

Playlist

Thumbnail for Why Should A Relay Meet The New NEMA 410 Standard? (S1 E1)

Why Should A Relay Meet The New NEMA 410 Standard? (S1 E1)

Thumbnail for Smart Grid Products: LF-G Series Power Relays

Smart Grid Products: LF-G Series Power Relays

Thumbnail for Smart Grid Products: HE-V Series Power Relays

Smart Grid Products: HE-V Series Power Relays

Thumbnail for Features and Benefits of PhotoMOS®

Features and Benefits of PhotoMOS®

Thumbnail for Introduction to PhotoMOS®

Introduction to PhotoMOS®

Thumbnail for Where Technology Meets Humanity

Where Technology Meets Humanity

Thumbnail for Panasonic Industrial Solutions for 5G Networking Applications

Panasonic Industrial Solutions for 5G Networking Applications

Thumbnail for New Product Spotlight: DW Series Relays

New Product Spotlight: DW Series Relays

Thumbnail for New Product Spotlight: PhotoMOS® HE 1 Form A and HE SOP 1 Form A Series Relays

New Product Spotlight: PhotoMOS® HE 1 Form A and HE SOP 1 Form A Series Relays

Thumbnail for New Product Spotlight: PA-N Series General Power Relays

New Product Spotlight: PA-N Series General Power Relays