Specifications

Specifications table for model JTV1S-PA-24V
ItemPerformance characteristics
Protective ConstructionSealed
Terminal TypePC board terminal
Rated Coil Voltage24 V DC
Contact Arrangement1 Form C
Operating Function Single side stable
Coil Insulation ClassClass F insulation
Packing Quantity; Inner Carton (Pcs.) 50
Packing Quantity; Outer Carton (Pcs.)500
Operate Voltage (@20oC)Max. 75% V of Rated coil voltage (initial)
Release Voltage (at20°C) Min. 10% V of Rated coil voltage (initial)
Rated Operating Current [±10%] (at 20°C)41.7 mA
Resistance [±10%] (at 20°C) 576 Ω
Rated Operating Power 1000 mW
Max. Allowable Voltage 120% V of Rated coil voltage (at 85°C)
Contact ShapeSingle
Contact Resistance (Initial)Max. 50 mΩ (by voltage drop 6 V DC 1 A)
Contact MaterialAgSnO2 type
Contact Rating (Resistive Load)N.C.: 10 A 277 V AC, N.O.: 20 A 277 V AC
Max. Switching Power (Resistive Load) N.C.: 2,770 VA, N.O.: 5,540 VA
Max. Switching Voltage277 V AC
Max. Switching CurrentN.C.: 10 A, N.O.: 20 A
Min. Switching Load (Reference Value) 100 mA 5 V DC
Insulation Resistance (Initial)Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric Strength (Initial): Between Open Contacts1,200 Vrms for 1 min. (detection current: 10 mA)
Dielectric Strength (Initial): Between Contact and Coil3,500 Vrms for 1 min. (detection current: 10 mA)
Surge Withstand Voltage (Initial): Between Contact and Coil6,000 V
Operate Time (Initial) (At 20oC)Max. 15 ms (at rated coil voltage, without bounce)
Release Time (Initial) (at 20°C) Max. 10 ms (at rated coil voltage, without bounce, without diode)
Hock Resistance (Functional)98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Hock Resistance (Destructive)980 m/s2 (half-sine shock pulse: 6 ms)
Vibration Resistance (Functional)10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
Vibration Resistance (Destructive)10 to 55 Hz (at double amplitude of 2.0 mm)
Mechanical LifeMin. 1x107 ope. (at 180 times/min.)
ConditionsAmbient temperature: -55 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Weight (Typ.)Approx. 25 g
Resistive LoadN.O.: Min. 100,000 ope. 20 A 277 V AC (at 20°C, at 20 times/min.)
N.C.: Min. 100,000 ope. 10 A 277 V AC (at 20°C, at 20 times/min.)

Stock check

JTV1S-PA-24V

Latest Videos

Playlist

Thumbnail for Why Should A Relay Meet The New NEMA 410 Standard? (S1 E1)

Why Should A Relay Meet The New NEMA 410 Standard? (S1 E1)

Thumbnail for Smart Grid Products: LF-G Series Power Relays

Smart Grid Products: LF-G Series Power Relays

Thumbnail for Smart Grid Products: HE-V Series Power Relays

Smart Grid Products: HE-V Series Power Relays

Thumbnail for Features and Benefits of PhotoMOS®

Features and Benefits of PhotoMOS®

Thumbnail for Introduction to PhotoMOS®

Introduction to PhotoMOS®

Thumbnail for Where Technology Meets Humanity

Where Technology Meets Humanity

Thumbnail for Panasonic Industrial Solutions for 5G Networking Applications

Panasonic Industrial Solutions for 5G Networking Applications

Thumbnail for New Product Spotlight: DW Series Relays

New Product Spotlight: DW Series Relays

Thumbnail for New Product Spotlight: PhotoMOS® HE 1 Form A and HE SOP 1 Form A Series Relays

New Product Spotlight: PhotoMOS® HE 1 Form A and HE SOP 1 Form A Series Relays

Thumbnail for New Product Spotlight: PA-N Series General Power Relays

New Product Spotlight: PA-N Series General Power Relays