| | 18 V DC | 200 mW | Flux-resistant | Single side stable | PC board terminal | Flat type | Class E insulation | 100 | 1,000 | Max. 75% V of Rated coil voltage (initial) | Min. 5% V of Rated coil voltage (initial) | 11.1 mA | 1,620 Ω | 150% V of Rated coil voltage | 1 Form A | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 16 A 125 V AC, 10 A 277 V AC, 10 A 30 V DC | 2,770 VA, 300 W | 277 V AC, 110 V DC (0.3 A) | 16 A (AC), 10 A (DC) | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 2,500 Vrms for 1 min. (detection current: 10 mA) | 4,500 V | Max. 5 ms (at rated coil voltage, without bounce, without diode) | Max. 12 ms (at rated coil voltage, without bounce) | 200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 2x107 ope. (at 180 times/min.) | Ambient temperature: -40 to +70°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 8 g | Min. 100,000 ope. 10 A 125 V AC (at 20°C, at 20 times/min.) Min. 100,000 ope. 10 A 30 V DC (at 20°C, at 20 times/min.) Min. 50,000 ope. 10 A 277 V AC (at 20°C, at 20 times/min.) Min. 30,000 ope. 16 A 125 V AC (at 20°C, at 20 times/min.) |
| | 6 V DC | 200 mW | Flux-resistant | Single side stable | PC board terminal | Flat type | Class E insulation | 100 | 1,000 | Max. 75% V of Rated coil voltage (initial) | Min. 5% V of Rated coil voltage (initial) | 33.3 mA | 180 Ω | 150% V of Rated coil voltage | 1 Form A | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 16 A 125 V AC, 10 A 277 V AC, 10 A 30 V DC | 2,770 VA, 300 W | 277 V AC, 110 V DC (0.3 A) | 16 A (AC), 10 A (DC) | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 2,500 Vrms for 1 min. (detection current: 10 mA) | 4,500 V | Max. 5 ms (at rated coil voltage, without bounce, without diode) | Max. 12 ms (at rated coil voltage, without bounce) | 200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 2x107 ope. (at 180 times/min.) | Ambient temperature: -40 to +70°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 8 g | Min. 100,000 ope. 10 A 125 V AC (at 20°C, at 20 times/min.) Min. 100,000 ope. 10 A 30 V DC (at 20°C, at 20 times/min.) Min. 50,000 ope. 10 A 277 V AC (at 20°C, at 20 times/min.) Min. 30,000 ope. 16 A 125 V AC (at 20°C, at 20 times/min.) |
| | 4.5 V DC | 200 mW | Flux-resistant | Single side stable | PC board terminal | Flat type | Class E insulation | 100 | 1,000 | Max. 75% V of Rated coil voltage (initial) | Min. 5% V of Rated coil voltage (initial) | 44.4 mA | 101 Ω | 150% V of Rated coil voltage | 1 Form A | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 16 A 125 V AC, 10 A 277 V AC, 10 A 30 V DC | 2,770 VA, 300 W | 277 V AC, 110 V DC (0.3 A) | 16 A (AC), 10 A (DC) | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 2,500 Vrms for 1 min. (detection current: 10 mA) | 4,500 V | Max. 5 ms (at rated coil voltage, without bounce, without diode) | Max. 12 ms (at rated coil voltage, without bounce) | 200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 2x107 ope. (at 180 times/min.) | Ambient temperature: -40 to +70°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 8 g | Min. 100,000 ope. 10 A 125 V AC (at 20°C, at 20 times/min.) Min. 100,000 ope. 10 A 30 V DC (at 20°C, at 20 times/min.) Min. 50,000 ope. 10 A 277 V AC (at 20°C, at 20 times/min.) Min. 30,000 ope. 16 A 125 V AC (at 20°C, at 20 times/min.) |
| | 24 V DC | 200 mW | Flux-resistant | Single side stable | PC board terminal | Flat type | Class E insulation | 100 | 1,000 | Max. 75% V of Rated coil voltage (initial) | Min. 5% V of Rated coil voltage (initial) | 8.3 mA | 2,880 Ω | 150% V of Rated coil voltage | 1 Form A | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 16 A 125 V AC, 10 A 277 V AC, 10 A 30 V DC | 2,770 VA, 300 W | 277 V AC, 110 V DC (0.3 A) | 16 A (AC), 10 A (DC) | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 2,500 Vrms for 1 min. (detection current: 10 mA) | 4,500 V | Max. 5 ms (at rated coil voltage, without bounce, without diode) | Max. 12 ms (at rated coil voltage, without bounce) | 200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 2x107 ope. (at 180 times/min.) | Ambient temperature: -40 to +70°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 8 g | Min. 100,000 ope. 10 A 125 V AC (at 20°C, at 20 times/min.) Min. 100,000 ope. 10 A 30 V DC (at 20°C, at 20 times/min.) Min. 50,000 ope. 10 A 277 V AC (at 20°C, at 20 times/min.) Min. 30,000 ope. 16 A 125 V AC (at 20°C, at 20 times/min.) |
| | 9 V DC | 200 mW | Flux-resistant | Single side stable | PC board terminal | Flat type | Class E insulation | 100 | 1,000 | Max. 75% V of Rated coil voltage (initial) | Min. 5% V of Rated coil voltage (initial) | 22.2 mA | 405 Ω | 150% V of Rated coil voltage | 1 Form A | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 16 A 125 V AC, 10 A 277 V AC, 10 A 30 V DC | 2,770 VA, 300 W | 277 V AC, 110 V DC (0.3 A) | 16 A (AC), 10 A (DC) | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 2,500 Vrms for 1 min. (detection current: 10 mA) | 4,500 V | Max. 5 ms (at rated coil voltage, without bounce, without diode) | Max. 12 ms (at rated coil voltage, without bounce) | 200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 2x107 ope. (at 180 times/min.) | Ambient temperature: -40 to +70°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 8 g | Min. 100,000 ope. 10 A 125 V AC (at 20°C, at 20 times/min.) Min. 100,000 ope. 10 A 30 V DC (at 20°C, at 20 times/min.) Min. 50,000 ope. 10 A 277 V AC (at 20°C, at 20 times/min.) Min. 30,000 ope. 16 A 125 V AC (at 20°C, at 20 times/min.) |
| | 12 V DC | 200 mW | Flux-resistant | Single side stable | PC board terminal | Flat type | Class E insulation | 100 | 1,000 | Max. 75% V of Rated coil voltage (initial) | Min. 5% V of Rated coil voltage (initial) | 16.7 mA | 720 Ω | 150% V of Rated coil voltage | 1 Form A | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 16 A 125 V AC, 10 A 277 V AC, 10 A 30 V DC | 2,770 VA, 300 W | 277 V AC, 110 V DC (0.3 A) | 16 A (AC), 10 A (DC) | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 2,500 Vrms for 1 min. (detection current: 10 mA) | 4,500 V | Max. 5 ms (at rated coil voltage, without bounce, without diode) | Max. 12 ms (at rated coil voltage, without bounce) | 200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 2x107 ope. (at 180 times/min.) | Ambient temperature: -40 to +70°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 8 g | Min. 100,000 ope. 10 A 125 V AC (at 20°C, at 20 times/min.) Min. 100,000 ope. 10 A 30 V DC (at 20°C, at 20 times/min.) Min. 50,000 ope. 10 A 277 V AC (at 20°C, at 20 times/min.) Min. 30,000 ope. 16 A 125 V AC (at 20°C, at 20 times/min.) |
| | 48 V DC | 200 mW | Flux-resistant | Single side stable | PC board terminal | Flat type | Class E insulation | 100 | 1,000 | Max. 75% V of Rated coil voltage (initial) | Min. 5% V of Rated coil voltage (initial) | 4.2 mA | 11,520 Ω | 150% V of Rated coil voltage | 1 Form A | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 16 A 125 V AC, 10 A 277 V AC, 10 A 30 V DC | 2,770 VA, 300 W | 277 V AC, 110 V DC (0.3 A) | 16 A (AC), 10 A (DC) | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 2,500 Vrms for 1 min. (detection current: 10 mA) | 4,500 V | Max. 5 ms (at rated coil voltage, without bounce, without diode) | Max. 12 ms (at rated coil voltage, without bounce) | 200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 2x107 ope. (at 180 times/min.) | Ambient temperature: -40 to +70°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 8 g | Min. 100,000 ope. 10 A 125 V AC (at 20°C, at 20 times/min.) Min. 100,000 ope. 10 A 30 V DC (at 20°C, at 20 times/min.) Min. 50,000 ope. 10 A 277 V AC (at 20°C, at 20 times/min.) Min. 30,000 ope. 16 A 125 V AC (at 20°C, at 20 times/min.) |
| | 100 V DC | 600 mW | Flux-resistant | Single side stable | PC board terminal | Flat type | Class E insulation | 100 | 1,000 | Max. 60 V DC (initial) | Min. 4 V DC (initial) | 6 mA | 16,600 Ω | 110 V DC | 1 Form A | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 16 A 125 V AC, 10 A 277 V AC, 10 A 30 V DC | 2,770 VA, 300 W | 277 V AC, 110 V DC (0.3 A) | 16 A (AC), 10 A (DC) | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 2,500 Vrms for 1 min. (detection current: 10 mA) | 4,500 V | Max. 5 ms (at rated coil voltage, without bounce, without diode) | Max. 8 ms (at rated coil voltage, without bounce) | 200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 2x107 ope. (at 180 times/min.) | Ambient temperature: -40 to +60°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 8 g | Min. 100,000 ope. 10 A 125 V AC (at 20°C, at 20 times/min.) Min. 100,000 ope. 10 A 30 V DC (at 20°C, at 20 times/min.) Min. 50,000 ope. 10 A 277 V AC (at 20°C, at 20 times/min.) Min. 30,000 ope. 16 A 125 V AC (at 20°C, at 20 times/min.) |