Specifications table for model LKG1AF-24V-16-1
ItemPerformance characteristics
Contact GapMin. 1mm
Rated Coil Voltage24 V DC
Contact Rating (Resistive Load)16 A 277 V AC
Protective ConstructionFlux-resistant
Operating Function Single side stable
Terminal TypePC board terminal
Contact Type16 A
Packing Quantity; Outer Carton (Pcs.)500
Packing Quantity; Inner Carton (Pcs.) 100
Operate Voltage (@20oC)Max. 75% V of Rated coil voltage (initial)
Release Voltage (at20°C) Min. 10% V of Rated coil voltage (initial)
Rated Operating Current [±10%] (at 20°C)22.1 mA
Resistance [±10%] (at 20°C) 1,087 Ω
Rated Operating Power 530 mW
Max. Allowable Voltage (at 20°C 68°F)130% V of Rated coil voltage
Contact Arrangement1 Form A
Contact Resistance (Initial)Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Max. Switching Power (Resistive Load) 4,432 VA
Contact MaterialAgSnO2 type
Max. Switching Voltage277 V AC
Max. Switching Current16 A (AC)
Min. Switching Load (Reference Value) 100 mA 5 V DC
Insulation Resistance (Initial)Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric Strength (Initial): Between Open Contacts1,000 Vrms for 1 min. (detection current: 10 mA)
Dielectric Strength (Initial): Between Contact and Coil4,000 Vrms for 1 min. (detection current: 10 mA)
Surge Withstand Voltage (Initial): Between Contact and Coil10,000 V
Operate Time (Initial) (At 20oC)Max. 15 ms (at rated coil voltage, without bounce)
Release Time (Initial) (at 20°C) Max. 20 ms (at rated coil voltage, without bounce, with diode)
Hock Resistance (Functional)200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Hock Resistance (Destructive)1,000 m/s2 (half-sine shock pulse: 6 ms)
Vibration Resistance (Functional)10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
Vibration Resistance (Destructive)10 to 55 Hz (at double amplitude of 1.5 mm)
Mechanical LifeMin. 2x106 ope. (at 180 times/min.)
ConditionsAmbient temperature: -40 to +70°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation.)
Weight (Typ.)Approx. 12 g
Resistive LoadMin. 50,000 ope. 16 A 277 V AC
(at 20°C, with diode, at 6 times/min., ON : OFF = 1 s : 9 s)
Insulation Distance[Between contact and coil]
Clearance: Min. 6 mm, Creepage: Min. 6 mm

Stock check

Model image for LKG1AF-24V-16-1

LKG1AF-24V-16-1

Resources

Filter by:
Showing 1 to 4 of 4 results
Results4
Latest Videos

Playlist

Thumbnail for Why Should A Relay Meet The New NEMA 410 Standard? (S1 E1)

Why Should A Relay Meet The New NEMA 410 Standard? (S1 E1)

Thumbnail for Smart Grid Products: LF-G Series Power Relays

Smart Grid Products: LF-G Series Power Relays

Thumbnail for Smart Grid Products: HE-V Series Power Relays

Smart Grid Products: HE-V Series Power Relays

Thumbnail for Features and Benefits of PhotoMOS®

Features and Benefits of PhotoMOS®

Thumbnail for Introduction to PhotoMOS®

Introduction to PhotoMOS®

Thumbnail for Where Technology Meets Humanity

Where Technology Meets Humanity

Thumbnail for Panasonic Industrial Solutions for 5G Networking Applications

Panasonic Industrial Solutions for 5G Networking Applications

Thumbnail for New Product Spotlight: DW Series Relays

New Product Spotlight: DW Series Relays

Thumbnail for New Product Spotlight: PhotoMOS® HE 1 Form A and HE SOP 1 Form A Series Relays

New Product Spotlight: PhotoMOS® HE 1 Form A and HE SOP 1 Form A Series Relays

Thumbnail for New Product Spotlight: PA-N Series General Power Relays

New Product Spotlight: PA-N Series General Power Relays