Panasonic’s NC Series Power Relays feature a high capacity of 5A 250VAC and 5A 30VDC (2 Form C) and 4A 250VAC and 5A 30VDC (4 Form C). These Relays are available with compact slim or flat design types. NC Series Relays are compatible with major safety standards, including UL, CSA, and Japanese Electrical Appliance and Material Control Law. The use of gold-clad twin bifurcated contacts provides stable contact resistance and ensures high contact reliability. NC Series Relays are also available with socket and terminal options for easier mounting.

Features and Benefits

  • Compact Slim Or Flat Design
  • High Reliability
  • 2 Form C or 4 Form C Contact Arrangement
  • RoHS / REACH Compliant
  • UL/C-UL, CSA Approved
  • Sockets And Terminals Available

Applications

  • Electric Power Equipment
  • Industrial Equipment
  • Measuring Devices
Series image for NC Series Relays

NC Series Relays

Part number list

Results 84
Models table for series NC Series Relays
Part No.DatasheetProtective ConstructionTerminal TypeRelay Shape Rated Coil VoltageRated Operating Power Contact ArrangementOperating Function AccessoriesPacking Quantity; Inner Carton (Pcs.) Packing Quantity; Outer Carton (Pcs.)Operate Voltage (@20oC)Release Voltage (at20°C) Rated Operating Current [±10%] (at 20°C)Resistance [±10%] (at 20°C) Max. Allowable Voltage Contact ShapeContact Resistance (Initial)Contact MaterialContact Rating (Resistive Load)Max. Switching Power (Resistive Load) Max. Switching VoltageMax. Switching CurrentMin. Switching Load (Reference Value) Insulation Resistance (Initial)Dielectric Strength (Initial): Between Open ContactsDielectric Strength (Initial): Between Contact SetsDielectric Strength (Initial): Between Contact and CoilOperate Time (Initial) (At 20oC)Release Time (Initial) (at 20°C) Hock Resistance (Functional)Hock Resistance (Destructive)Vibration Resistance (Functional) Vibration Resistance (Destructive)Mechanical LifeConditionsWeight (Typ.)Resistive Load
Dust Cover
Plug-in terminal
Slim type
100 V DC
740 mW
2 Form C
Single side stable
Socket and terminal are available.
20
200
Max. 80% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
7.4 mA
13,500 Ω
110% V of rated coil voltage (at 50℃)
Twin
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
Au-clad AgNi type
5 A 250 V AC, 5 A 30 V DC
1,250 VA, 150 W
250 V AC, 220 V DC
5 A (AC, DC)
100 μA 1 V DC
Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
1,000 Vrms for 1 min (detection current: 10 mA)
2,000 Vrms for 1 min (detection current: 10 mA)
Max. 20 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +55℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 16 g
[switching frequency: 20 times/min]
Min. 500x103 ope. 5 A 30 V DC
Min. 100x103 ope. 5 A 250 V AC
Sealed
Plug-in terminal
Slim type
12 V DC
360 mW
2 Form C
Single side stable
Socket and terminal are available.
20
200
Max. 80% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
30 mA
400 Ω
135% V of rated coil voltage (at 50℃)
Twin
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
Au-clad AgNi type
3 A 250 V AC, 5 A 30 V DC
750 VA, 150 W
250 V AC, 220 V DC
3 A (AC), 5 A (DC)
100 μA 1 V DC
Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
1,000 Vrms for 1 min (detection current: 10 mA)
2,000 Vrms for 1 min (detection current: 10 mA)
Max. 20 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 16 g
[switching frequency: 20 times/min]
Min. 500x103 ope. 5 A 30 V DC
Min. 100x103 ope. 3 A 250 V AC
Sealed
Plug-in terminal
Slim type
3 V DC
360 mW
2 Form C
Single side stable
Socket and terminal are available.
20
200
Max. 80% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
120 mA
25 Ω
135% V of rated coil voltage (at 50℃)
Twin
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
Au-clad AgNi type
3 A 250 V AC, 5 A 30 V DC
750 VA, 150 W
250 V AC, 220 V DC
3 A (AC), 5 A (DC)
100 μA 1 V DC
Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
1,000 Vrms for 1 min (detection current: 10 mA)
2,000 Vrms for 1 min (detection current: 10 mA)
Max. 20 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 16 g
[switching frequency: 20 times/min]
Min. 500x103 ope. 5 A 30 V DC
Min. 100x103 ope. 3 A 250 V AC
Sealed
Plug-in terminal
Slim type
6 V DC
360 mW
2 Form C
Single side stable
Socket and terminal are available.
20
200
Max. 80% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
60 mA
100 Ω
135% V of rated coil voltage (at 50℃)
Twin
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
Au-clad AgNi type
3 A 250 V AC, 5 A 30 V DC
750 VA, 150 W
250 V AC, 220 V DC
3 A (AC), 5 A (DC)
100 μA 1 V DC
Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
1,000 Vrms for 1 min (detection current: 10 mA)
2,000 Vrms for 1 min (detection current: 10 mA)
Max. 20 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 16 g
[switching frequency: 20 times/min]
Min. 500x103 ope. 5 A 30 V DC
Min. 100x103 ope. 3 A 250 V AC
Sealed
Plug-in terminal
Slim type
100 V DC
740 mW
2 Form C
Single side stable
Socket and terminal are available.
20
200
Max. 80% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
7.4 mA
13,500 Ω
110% V of rated coil voltage (at 50℃)
Twin
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
Au-clad AgNi type
3 A 250 V AC, 5 A 30 V DC
750 VA, 150 W
250 V AC, 220 V DC
3 A (AC), 5 A (DC)
100 μA 1 V DC
Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
1,000 Vrms for 1 min (detection current: 10 mA)
2,000 Vrms for 1 min (detection current: 10 mA)
Max. 20 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +55℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 16 g
[switching frequency: 20 times/min]
Min. 500x103 ope. 5 A 30 V DC
Min. 100x103 ope. 3 A 250 V AC
Sealed
Plug-in terminal
Slim type
48 V DC
360 mW
2 Form C
Single side stable
Socket and terminal are available.
20
200
Max. 80% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
7.5 mA
6,400 Ω
135% V of rated coil voltage (at 50℃)
Twin
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
Au-clad AgNi type
3 A 250 V AC, 5 A 30 V DC
750 VA, 150 W
250 V AC, 220 V DC
3 A (AC), 5 A (DC)
100 μA 1 V DC
Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
1,000 Vrms for 1 min (detection current: 10 mA)
2,000 Vrms for 1 min (detection current: 10 mA)
Max. 20 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 16 g
[switching frequency: 20 times/min]
Min. 500x103 ope. 5 A 30 V DC
Min. 100x103 ope. 3 A 250 V AC
Sealed
Plug-in terminal
Slim type
5 V DC
360 mW
2 Form C
Single side stable
Socket and terminal are available.
20
200
Max. 80% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
72 mA
69.4 Ω
135% V of rated coil voltage (at 50℃)
Twin
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
Au-clad AgNi type
3 A 250 V AC, 5 A 30 V DC
750 VA, 150 W
250 V AC, 220 V DC
3 A (AC), 5 A (DC)
100 μA 1 V DC
Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
1,000 Vrms for 1 min (detection current: 10 mA)
2,000 Vrms for 1 min (detection current: 10 mA)
Max. 20 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 16 g
[switching frequency: 20 times/min]
Min. 500x103 ope. 5 A 30 V DC
Min. 100x103 ope. 3 A 250 V AC
Dust Cover
Plug-in terminal
Slim type
24 V DC
720 mW
4 Form C
Single side stable
Sockets are available.
20
200
Max. 80% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
30 mA
800 Ω
110% V of rated coil voltage (at 50℃)
Twin
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
Au-clad AgNi type
4 A 250 V AC, 5 A 30 V DC
1,000 VA, 150 W
250 V AC, 220 V DC
4 A (AC), 5 A (DC)
100 μA 1 V DC
Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
1,000 Vrms for 1 min (detection current: 10 mA)
2,000 Vrms for 1 min (detection current: 10 mA)
Max. 20 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +55℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 19 g
[switching frequency: 20 times/min]
Min. 500x103 ope. 5 A 30 V DC
Min. 100x103 ope. 4 A 250 V AC
Dust Cover
Plug-in terminal
Slim type
3 V DC
720 mW
4 Form C
Single side stable
Sockets are available.
20
200
Max. 80% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
240 mA
12.5 Ω
110% V of rated coil voltage (at 50℃)
Twin
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
Au-clad AgNi type
4 A 250 V AC, 5 A 30 V DC
1,000 VA, 150 W
250 V AC, 220 V DC
4 A (AC), 5 A (DC)
100 μA 1 V DC
Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
1,000 Vrms for 1 min (detection current: 10 mA)
2,000 Vrms for 1 min (detection current: 10 mA)
Max. 20 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +55℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 19 g
[switching frequency: 20 times/min]
Min. 500x103 ope. 5 A 30 V DC
Min. 100x103 ope. 4 A 250 V AC
Dust Cover
Plug-in terminal
Slim type
12 V DC
720 mW
4 Form C
Single side stable
Sockets are available.
20
200
Max. 80% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
60 mA
200 Ω
110% V of rated coil voltage (at 50℃)
Twin
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
Au-clad AgNi type
4 A 250 V AC, 5 A 30 V DC
1,000 VA, 150 W
250 V AC, 220 V DC
4 A (AC), 5 A (DC)
100 μA 1 V DC
Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
1,000 Vrms for 1 min (detection current: 10 mA)
2,000 Vrms for 1 min (detection current: 10 mA)
Max. 20 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +55℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 19 g
[switching frequency: 20 times/min]
Min. 500x103 ope. 5 A 30 V DC
Min. 100x103 ope. 4 A 250 V AC
Latest Videos

Playlist

Thumbnail for Smart Grid Products: LF-G Series Power Relays

Smart Grid Products: LF-G Series Power Relays

Thumbnail for Smart Grid Products: HE-V Series Power Relays

Smart Grid Products: HE-V Series Power Relays

Thumbnail for New Product Spotlight: DW Series Relays

New Product Spotlight: DW Series Relays

Thumbnail for New Product Spotlight: PA-N Series General Power Relays

New Product Spotlight: PA-N Series General Power Relays

Thumbnail for New Product Brief: EV-A Series Automotive Relay

New Product Brief: EV-A Series Automotive Relay

Thumbnail for New Product Brief: TB Series Automotive Relays

New Product Brief: TB Series Automotive Relays

Thumbnail for NPI: SF-M Series Relays

NPI: SF-M Series Relays

Thumbnail for SF-M Series Safety Relays

SF-M Series Safety Relays

Thumbnail for New Product Introduction: HE-R Series General Power Relays

New Product Introduction: HE-R Series General Power Relays

Thumbnail for New Product Introduction: HE Series Power Relay PV Type 90A Wide Gap

New Product Introduction: HE Series Power Relay PV Type 90A Wide Gap