Fiber Sensors: Digital Fiber Sensor FX-550

Model List

Found 4 matches. Display 1 - 4 matches.
Part No.sort descendingData SheetCE marking directive complianceSupply voltagePower consumptionOutputOutput:Output operationOutput:Short-circuit protectionResponse timeSensitivity settingIncident light sensitivity settingIncident light intensity display rangeParts Inventory
   Column active Filter
Close

Filter by CE marking directive compliance

Column active Filter
Close

Filter by Supply voltage

Column active Filter
Close

Filter by Power consumption

Column active Filter
Close

Filter by Output

Column active Filter
Close

Filter by Output:Output operation

Column active Filter
Close

Filter by Output:Short-circuit protection

Column active Filter
Close

Filter by Response time

Column active Filter
Close

Filter by Sensitivity setting

Column active Filter
Close

Filter by Incident light sensitivity setting

Column active Filter
Close

Filter by Incident light intensity display range

 
design engineersPanasonicFX-551
EMC Directive, RoHS Directive12 to 24 V DC +10-15 % Ripple P-P 10 % or lessNormal operation : 960 mW or less (current consumption 40 mA or less at 24 V supply voltage)
ECO mode : 680 mW or less (current consumption 28 mA or less at 24 V supply voltage)

NPN open-collector transistor
・Maximum sink current : 100 mA
・Applied voltage : 30 V DC or less (between output and 0 V)
・Residual voltage : 2 V or less (Note) (at maximum sink current)
(Note): In case of using the quick-connection cable (cable length 5 m 16.404 ft)(optional).
Switchable either Light-ON or Dark-ON by L/D modeIncorporatedFAST : 60μs or less, STD : 250μs or less, LONG : 2ms or less, U-LG : 4ms or less, HYPR : 24ms or less, selectable2-point teaching / Limit teaching / Full-auto teaching / Manual adjustmentIncorporated, 4 stepsFAST / STD : 0 to 4,000, LONG : 0 to 8,000, U-LG / HYPR : 0 to 9,999
design engineersPanasonicFX-551P
EMC Directive, RoHS Directive12 to 24 V DC +10-15 % Ripple P-P 10 % or lessNormal operation : 960 mW or less (current consumption 40 mA or less at 24 V supply voltage)
ECO mode : 680 mW or less (current consumption 28 mA or less at 24 V supply voltage)

PNP open-collector transistor
・Maximum source current : 100 mA
・Applied voltage : 30 V DC or less (between output and +V)
・Residual voltage : 2 V or less (Note) (at maximum source current)
(Note): In case of using the quick-connection cable (cable length 5 m 16.404 ft)(optional).
Switchable either Light-ON or Dark-ON by L/D modeIncorporatedFAST : 60μs or less, STD : 250μs or less, LONG : 2ms or less, U-LG : 4ms or less, HYPR : 24ms or less, selectable2-point teaching / Limit teaching / Full-auto teaching / Manual adjustmentIncorporated, 4 stepsFAST / STD : 0 to 4,000, LONG : 0 to 8,000, U-LG / HYPR : 0 to 9,999
design engineersPanasonicFX-551P-C2
EMC Directive, RoHS Directive12 to 24 V DC +10-15 % Ripple P-P 10 % or lessNormal operation : 960 mW or less (current consumption 40 mA or less at 24 V supply voltage)
ECO mode : 680 mW or less (current consumption 28 mA or less at 24 V supply voltage)

PNP open-collector transistor
・Maximum source current : 100 mA
・Applied voltage : 30 V DC or less (between output and +V)
・Residual voltage : 2 V or less (at maximum source current)
Switchable either Light-ON or Dark-ON by L/D modeIncorporatedFAST : 60μs or less, STD : 250μs or less, LONG : 2ms or less, U-LG : 4ms or less, HYPR : 24ms or less, selectable2-point teaching / Limit teaching / Full-auto teaching / Manual adjustmentIncorporated, 4 stepsFAST / STD : 0 to 4,000, LONG : 0 to 8,000, U-LG / HYPR : 0 to 9,999
design engineersPanasonicFX-551-C2
EMC Directive, RoHS Directive12 to 24 V DC +10-15 % Ripple P-P 10 % or lessNormal operation : 960 mW or less (current consumption 40 mA or less at 24 V supply voltage)
ECO mode : 680 mW or less (current consumption 28 mA or less at 24 V supply voltage)

NPN open-collector transistor
・Maximum sink current : 100 mA
・Applied voltage : 30 V DC or less (between output and 0 V)
・Residual voltage : 2 V or less (at maximum sink current)
Switchable either Light-ON or Dark-ON by L/D modeIncorporatedFAST : 60μs or less, STD : 250μs or less, LONG : 2ms or less, U-LG : 4ms or less, HYPR : 24ms or less, selectable2-point teaching / Limit teaching / Full-auto teaching / Manual adjustmentIncorporated, 4 stepsFAST / STD : 0 to 4,000, LONG : 0 to 8,000, U-LG / HYPR : 0 to 9,999

Related Documents

Sensors › Factory Automation Sensors › Fiber Sensors › Digital Fiber Sensor FX-550 › FX-100 Sensing Characteristics Data sheetFX-100 Sensing Characteristics Data sheet
Sensors › Factory Automation Sensors › Fiber Sensors › Digital Fiber Sensor FX-550 › FX-100 Sensing rangeFX-100 Sensing range
Sensors › Factory Automation Sensors › Fiber Sensors › Digital Fiber Sensor FX-550 › FX-300 Sensing Characteristics Data sheetFX-300 Sensing Characteristics Data sheet
Sensors › Factory Automation Sensors › Fiber Sensors › Digital Fiber Sensor FX-550 › FX-300 Sensing rangeFX-300 Sensing range
Sensors › Factory Automation Sensors › Fiber Sensors › Digital Fiber Sensor FX-550 › FX-311 Sensing rangeFX-311 Sensing range
Sensors › Factory Automation Sensors › Fiber Sensors › Digital Fiber Sensor FX-550 › FX-410 Sensing rangeFX-410 Sensing range
Sensors › Factory Automation Sensors › Fiber Sensors › Digital Fiber Sensor FX-550 › FX-500 Sensing Characteristics Data sheetFX-500 Sensing Characteristics Data sheet
Sensors › Factory Automation Sensors › Fiber Sensors › Digital Fiber Sensor FX-550 › FX-500 Sensing rangeFX-500 Sensing range
Sensors › Factory Automation Sensors › Fiber Sensors › Digital Fiber Sensor FX-550 › FX-550FX-550