Fiber Sensors: Manually Set Fiber Sensor FX-311
Model List
Found 6 matches. Display 1 - 6 matches.
Part No.![]() | Data Sheet | Supply voltage | Power consumption | Output | Output:Output operation | Output:Short-circuit protection | Response time | Operation indicator | Stability indicator | Sensitivity adjuster | Timer function | Parts Inventory |
---|---|---|---|---|---|---|---|---|---|---|---|---|
![]()
Close
Filter by Supply voltage |
![]()
Close
Filter by Power consumption |
![]()
Close
Filter by Output |
![]()
Close
Filter by Output:Output operation |
![]()
Close
Filter by Output:Short-circuit protection |
![]()
Close
Filter by Response time |
![]()
Close
Filter by Operation indicator |
![]()
Close
Filter by Stability indicator |
![]()
Close
Filter by Sensitivity adjuster |
![]()
Close
Filter by Timer function | |||
Sensors › Factory Automation Sensors › Fiber Sensors › Manually Set Fiber Sensor FX-311 › FX-311 › Data sheet | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | 840 mW or less (Current consumption 35 mA or less at 24 V supply voltage) | NPN open-collector transistor • Maximum sink current: 100 mA (50 mA, if five, or more, amplifiers are connected in cascade) • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1.5 V or less [at 100 mA sink current (50 mA, if five, or more, amplifiers are connected in cascade)] | Selectable either Light-ON or Dark-ON, with selection switch | Incorporated | 250 μs or less (STD / S-D), 2 ms or less (LONG) selectable with selection switch | Orange LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | 12-turn potentiometer with indicator (Pointer part: red backlight) (Note):The red backlight of the pointer part lights up more brightly when the power is turned ON and when the sensitivity is adjusted. | Incorporated with OFF-delay timer, selectable either effective (approx. 10 ms or 40 ms) or ineffective | ![]() | |
Sensors › Factory Automation Sensors › Fiber Sensors › Manually Set Fiber Sensor FX-311 › FX-311BP › Data sheet | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | 840 mW or less (Current consumption 35 mA or less at 24 V supply voltage) | PNP open-collector transistor • Maximum source current: 100 mA(50 mA, if five, or more, amplifiers are connected in cascade) • Applied voltage: 30 V DC or less (between output and +V) • Residual voltage: 1.5 V or less[at 100 mA sink current (50 mA, if five, or more, amplifiers are connected in cascade)] | Selectable either Light-ON or Dark-ON, with selection switch | Incorporated | 150 μs or less (FAST), 250 μs or less (STD), 2 ms or less (LONG) selectable with selection switch | Orange LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | 12-turn potentiometer with indicator (Pointer part: red backlight) (Note):The red backlight of the pointer part lights up more brightly when the power is turned ON and when the sensitivity is adjusted. | Incorporated with OFF-delay timer, selectable either effective (approx. 10 ms or 40 ms) or ineffective | ![]() | |
Sensors › Factory Automation Sensors › Fiber Sensors › Manually Set Fiber Sensor FX-311 › FX-311G › Data sheet | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | 840 mW or less (Current consumption 35 mA or less at 24 V supply voltage) | NPN open-collector transistor • Maximum sink current: 100 mA (50 mA, if five, or more, amplifiers are connected in cascade) • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1.5 V or less [at 100 mA sink current (50 mA, if five, or more, amplifiers are connected in cascade)] | Selectable either Light-ON or Dark-ON, with selection switch | Incorporated | 150 μs or less (FAST), 250 μs or less (STD), 2 ms or less (LONG) selectable with selection switch | Orange LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | 12-turn potentiometer with indicator (Pointer part: red backlight) (Note):The red backlight of the pointer part lights up more brightly when the power is turned ON and when the sensitivity is adjusted. | Incorporated with OFF-delay timer, selectable either effective (approx. 10 ms or 40 ms) or ineffective | ![]() | |
Sensors › Factory Automation Sensors › Fiber Sensors › Manually Set Fiber Sensor FX-311 › FX-311GP › Data sheet | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | 840 mW or less (Current consumption 35 mA or less at 24 V supply voltage) | PNP open-collector transistor • Maximum source current: 100 mA(50 mA, if five, or more, amplifiers are connected in cascade) • Applied voltage: 30 V DC or less (between output and +V) • Residual voltage: 1.5 V or less[at 100 mA sink current (50 mA, if five, or more, amplifiers are connected in cascade)] | Selectable either Light-ON or Dark-ON, with selection switch | Incorporated | 150 μs or less (FAST), 250 μs or less (STD), 2 ms or less (LONG) selectable with selection switch | Orange LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | 12-turn potentiometer with indicator (Pointer part: red backlight) (Note):The red backlight of the pointer part lights up more brightly when the power is turned ON and when the sensitivity is adjusted. | Incorporated with OFF-delay timer, selectable either effective (approx. 10 ms or 40 ms) or ineffective | ![]() | |
Sensors › Factory Automation Sensors › Fiber Sensors › Manually Set Fiber Sensor FX-311 › FX-311P › Data sheet | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | 840 mW or less (Current consumption 35 mA or less at 24 V supply voltage) | PNP open-collector transistor • Maximum source current: 100 mA(50 mA, if five, or more, amplifiers are connected in cascade) • Applied voltage: 30 V DC or less (between output and +V) • Residual voltage: 1.5 V or less[at 100 mA sink current (50 mA, if five, or more, amplifiers are connected in cascade)] | Selectable either Light-ON or Dark-ON, with selection switch | Incorporated | 250 μs or less (STD / S-D), 2 ms or less (LONG) selectable with selection switch | Orange LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | 12-turn potentiometer with indicator (Pointer part: red backlight) (Note):The red backlight of the pointer part lights up more brightly when the power is turned ON and when the sensitivity is adjusted. | Incorporated with OFF-delay timer, selectable either effective (approx. 10 ms or 40 ms) or ineffective | ![]() | |
Sensors › Factory Automation Sensors › Fiber Sensors › Manually Set Fiber Sensor FX-311 › FX-311B › Data sheet | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | 840 mW or less (Current consumption 35 mA or less at 24 V supply voltage) | NPN open-collector transistor • Maximum sink current: 100 mA (50 mA, if five, or more, amplifiers are connected in cascade) • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1.5 V or less [at 100 mA sink current (50 mA, if five, or more, amplifiers are connected in cascade)] | Selectable either Light-ON or Dark-ON, with selection switch | Incorporated | 150 μs or less (FAST), 250 μs or less (STD), 2 ms or less (LONG) selectable with selection switch | Orange LED (lights up when the output is ON) | Green LED (lights up under stable light received condition or stable dark condition) | 12-turn potentiometer with indicator (Pointer part: red backlight) (Note):The red backlight of the pointer part lights up more brightly when the power is turned ON and when the sensitivity is adjusted. | Incorporated with OFF-delay timer, selectable either effective (approx. 10 ms or 40 ms) or ineffective | ![]() |