HG-S Series Contact-Type Digital Displacement Sensor

Introducing the New Contact-Type Digital Displacement Sensor featuring the optical absolute method in the slim and strong unit body.  Developed to meet the needs of the production floor, this high-precision, slim Sensor unit features a robust sensor head, while the controller offers a diversity of functions.

Features:

  • Slim body measuring 0.433 x 0.709 x 3.327 inches for easy installation even in a side-by-side arrangement
  • Class-top robustness in the industry
  • High accuracy in Class
  • Resolution of 0.1 μm 0.004 mil and indication accuracy of 1 μm 0.039 mil or less
  • Absolute value scale reading for elimination of “value skipping” and “unset zero point”

Model List

Found 12 matches. Display 1 - 12 matches.
Part No.sort descendingData SheetApplicable controllerPosition detection methodMeasuring rangeStrokeMeasuring force : Downward mountMeasuring force : Upward mountMeasuring force : Side mountResolutionIndication accuracy(P-P)Tip deviation amountParts Inventory
   Column active Filter
Close

Filter by Applicable controller

Column active Filter
Close

Filter by Position detection method

Column active Filter
Close

Filter by Measuring range

Column active Filter
Close

Filter by Stroke

Column active Filter
Close

Filter by Measuring force : Downward mount

Column active Filter
Close

Filter by Measuring force : Upward mount

Column active Filter
Close

Filter by Measuring force : Side mount

Column active Filter
Close

Filter by Resolution

Column active Filter
Close

Filter by Indication accuracy(P-P)

Column active Filter
Close

Filter by Tip deviation amount

 
design engineersPanasonicHG-S1010
HG-SC101(-P), HG-SC111(-P), HG-SC112(-P), HG-SC113Optical absolute linear encoder method10 mm 0.394 in10.5 mm 0.413 in or more1.65 N or less
1.10 N
(Note 1): Measured at an ambient temperature of +20 ℃ +68 ℉.
(Note 2): Typical value near center of measurement.
1.35 N or less
0.85 N
(Note 1): Measured at an ambient temperature of +20 ℃ +68 ℉.
(Note 2): Typical value near center of measurement.
1.50 N or less
0.95 N
(Note 1): Measured at an ambient temperature of +20 ℃ +68 ℉.
(Note 2): Typical value near center of measurement.
0.5 μm 0.020 milFull range: 2.0 μm 0.079 mil or less
Narrow range: 1.0 μm 0.039 mil or less
(any 60 μm 2.362 mil)
(Note): Measured at an ambient temperature of +20 ℃ +68 ℉.
35 μm 1.378 mil (typical)
design engineersPanasonicHG-S1010R
HG-SC101(-P), HG-SC111(-P), HG-SC112(-P), HG-SC113Optical absolute linear encoder method10 mm 0.394 in10.5 mm 0.413 in or more0.35 N or less
0.30 N
(Note 1): Measured at an ambient temperature of +20 ℃ +68 ℉.
(Note 2): In the case of low measurement force type (HG-S1010R / HG-S1110R), measurements were obtained with products in standard configuration without rubber bellows.
(Note 3): Typical value near center of measurement.
n/a0.25 N or less
0.20 N
(Note 1): Measured at an ambient temperature of +20 ℃ +68 ℉.
(Note 2): In the case of low measurement force type (HG-S1010R / HG-S1110R), measurements were obtained with products in standard configuration without rubber bellows.
(Note 3): Typical value near center of measurement.
0.5 μm 0.020 milFull range: 2.0 μm 0.079 mil or less
Narrow range: 1.0 μm 0.039 mil or less
(any 60 μm 2.362 mil)
(Note): Measured at an ambient temperature of +20 ℃ +68 ℉.
35 μm 1.378 mil (typical)
design engineersPanasonicHG-S1110
HG-SC101(-P), HG-SC111(-P), HG-SC112(-P), HG-SC113Optical absolute linear encoder method10 mm 0.394 in10.5 mm 0.413 in or more1.65 N or less
1.10 N
(Note 1): Measured at an ambient temperature of +20 ℃ +68 ℉.
(Note 2): Typical value near center of measurement.
1.35 N or less
0.85 N
(Note 1): Measured at an ambient temperature of +20 ℃ +68 ℉.
(Note 2): Typical value near center of measurement.
1.50 N or less
0.95 N
(Note 1): Measured at an ambient temperature of +20 ℃ +68 ℉.
(Note 2): Typical value near center of measurement.
0.1 μm 0.004 milFull range: 1.0 μm 0.039 mil or less
Narrow range: 0.5 μm 0.020 mil or less
(any 60 μm 2.362 mil)
(Note): Measured at an ambient temperature of +20 ℃ +68 ℉.
35 μm 1.378 mil (typical)
design engineersPanasonicHG-S1110R
HG-SC101(-P), HG-SC111(-P), HG-SC112(-P), HG-SC113Optical absolute linear encoder method10 mm 0.394 in10.5 mm 0.413 in or more0.35 N or less
0.30 N
(Note 1): Measured at an ambient temperature of +20 ℃ +68 ℉.
(Note 2): In the case of low measurement force type (HG-S1010R / HG-S1110R), measurements were obtained with products in standard configuration without rubber bellows.
(Note 3): Typical value near center of measurement.
n/a0.25 N or less
0.20 N
(Note 1): Measured at an ambient temperature of +20 ℃ +68 ℉.
(Note 2): In the case of low measurement force type (HG-S1010R / HG-S1110R), measurements were obtained with products in standard configuration without rubber bellows.
(Note 3): Typical value near center of measurement.
0.1 μm 0.004 milFull range: 1.0 μm 0.039 mil or less
Narrow range: 0.5 μm 0.020 mil or less
(any 60 μm 2.362 mil)
(Note): Measured at an ambient temperature of +20 ℃ +68 ℉.
35 μm 1.378 mil (typical)
design engineersPanasonicHG-SC101
n/an/an/an/an/an/an/an/an/an/a
design engineersPanasonicHG-SC101-P
n/an/an/an/an/an/an/an/an/an/a
design engineersPanasonicHG-SC111
n/an/an/an/an/an/an/an/an/an/a
design engineersPanasonicHG-SC111-P
n/an/an/an/an/an/an/an/an/an/a
design engineersPanasonicHG-SC112
n/an/an/an/an/an/an/an/an/an/a
design engineersPanasonicHG-SC112-P
n/an/an/an/an/an/an/an/an/an/a
design engineersPanasonicHG-SC113
n/an/an/an/an/an/an/an/an/an/a
design engineersPanasonicHG-S1032
HG-SC101(-P), HG-SC111(-P), HG-SC112(-P), HG-SC113Optical absolute linear encoder method32mm 1.260 in32.5 mm 1.280 in or more2.97 N or less
1.90 N
(Note 1): Measured at an ambient temperature of +20 ℃ +68 ℉.
(Note 2): Typical value near center of measurement.
2.09 N or less
1.19 N
(Note 1): Measured at an ambient temperature of +20 ℃ +68 ℉.
(Note 2): Typical value near center of measurement.
2.53 N or less
1.50 N
(Note 1): Measured at an ambient temperature of +20 ℃ +68 ℉.
(Note 2): Typical value near center of measurement.
0.5 μm 0.020 milFull range: 3.0 μm 0.118 mil or less
Narrow range: 2.0 μm 0.079 mil or less
(any 60 μm 2.362 mil)
(Note): Measured at an ambient temperature of +20 ℃ +68 ℉.