Laser Measurement Sensors: Ultra-compact Laser Collimated Beam Sensor HL-T1

Model List

Found 8 matches. Display 1 - 8 matches.
Part No.sort descendingData SheetTypeCE marking directive complianceApplicable controllerSensing rangeEmission indicatorInterference prevention functionParts Inventory
   Column active Filter
Close

Filter by Type

Column active Filter
Close

Filter by CE marking directive compliance

Column active Filter
Close

Filter by Applicable controller

Column active Filter
Close

Filter by Sensing range

Column active Filter
Close

Filter by Emission indicator

Column active Filter
Close

Filter by Interference prevention function

 
design engineersPanasonicHL-T1001F
Beam diameter dia.1 mm dia.0.039 in typeEMC Directive, RoHS DirectiveHL-AC1, HL-AC1P■■【In the case of(0 to 500 mm 0 to 19.685 in)】■■
Sensing width:
ø1 mm ø0.039 in

Min. sensing object:
ø8 micro m ø0.315 mil opaque object

Repeatability (During the state in which light is half blocked):
4 micro m 0.157 mil
(Note:In case of an average sampling rate of 64 times.)

Linear output resolution:
4 micro m 0.157 mil
(Note) In case of an average sampling rate of 64 times.
(Note)Value calculated with the linear output allowance factor (plus or minus 3 sigma) when connected to the controller included in the calculation of the detection width.
(Note:This value was obtained by converting the range of linear output fluctuation (plus or minus 3 sigma) into a sensing width, assuming that the smallest sensing object blocks the beam at the approximate center of the beam diameter of ø1 mm ø0.039 in.)


■■【In the case of (500 to 2,000 mm 19.685 to 78.74 in)】■■
Sensing width:
ø1 to ø2.5 mm ø0.039 to ø0.098 in

Min. sensing object:
ø50 micro m ø1.969 mil opaque object
Repeatability (During the state in which light is half blocked): -

Linear output resolution: -
-
Green LED (lights up during laser emission)Two units of sensors can be mounted close together. (When the controller interference prevention function is used)
design engineersPanasonicHL-AC1
NPN outputEMC Directive, RoHS Directiven/an/an/an/a
design engineersPanasonicHL-T1001A
Beam diameter dia.1 mm dia.0.039 in typeEMC Directive, RoHS DirectiveHL-AC1, HL-AC1P■■【In the case of(0 to 500 mm 0 to 19.685 in)】■■
Sensing width:
ø1 mm ø0.039 in

Min. sensing object:
ø8 micro m ø0.315 mil opaque object

Repeatability (During the state in which light is half blocked):
4 micro m 0.157 mil
(Note:In case of an average sampling rate of 64 times.)

Linear output resolution:
4 micro m 0.157 mil
(Note) In case of an average sampling rate of 64 times.
(Note)Value calculated with the linear output allowance factor (plus or minus 3 sigma) when connected to the controller included in the calculation of the detection width.
(Note:This value was obtained by converting the range of linear output fluctuation (plus or minus 3 sigma) into a sensing width, assuming that the smallest sensing object blocks the beam at the approximate center of the beam diameter of ø1 mm ø0.039 in.)


■■【In the case of (500 to 2,000 mm 19.685 to 78.74 in)】■■
Sensing width:
ø1 to ø2.5 mm ø0.039 to ø0.098 in

Min. sensing object:
ø50 micro m ø1.969 mil opaque object
Repeatability (During the state in which light is half blocked): -

Linear output resolution: -
-
Green LED (lights up during laser emission)Two units of sensors can be mounted close together. (When the controller interference prevention function is used)
design engineersPanasonicHL-T1005A
Sensing width 5 mm 0.197 in typeEMC Directive, RoHS DirectiveHL-AC1, HL-AC1P■■【In the case of(0 to 500 mm 0 to 19.685 in)】■■
Sensing width:
ø1 mm ø0.039 in

Min. sensing object:
ø8 micro m ø0.315 mil opaque object

Repeatability (During the state in which light is half blocked):
4 micro m 0.157 mil
(Note:In case of an average sampling rate of 64 times.)

Linear output resolution:
4 micro m 0.157 mil
(Note) In case of an average sampling rate of 64 times.
(Note)Value calculated with the linear output allowance factor (plus or minus 3 sigma) when connected to the controller included in the calculation of the detection width.
(Note:This value was obtained by converting the range of linear output fluctuation (plus or minus 3 sigma) into a sensing width, assuming that the smallest sensing object blocks the beam at the approximate center of the beam diameter of ø1 mm ø0.039 in.)


■■【In the case of (500 to 2,000 mm 19.685 to 78.74 in)】■■
Sensing width:
ø1 to ø2.5 mm ø0.039 to ø0.098 in

Min. sensing object:
ø50 micro m ø1.969 mil opaque object
Repeatability (During the state in which light is half blocked): -

Linear output resolution: -
-
Green LED (lights up during laser emission)Two units of sensors can be mounted close together. (When the controller interference prevention function is used)
design engineersPanasonicHL-T1005F
Sensing width 5 mm 0.197 in typeEMC Directive, RoHS DirectiveHL-AC1, HL-AC1P■■【In the case of(0 to 500 mm 0 to 19.685 in)】■■
Sensing width:
ø1 mm ø0.039 in

Min. sensing object:
ø8 micro m ø0.315 mil opaque object

Repeatability (During the state in which light is half blocked):
4 micro m 0.157 mil
(Note:In case of an average sampling rate of 64 times.)

Linear output resolution:
4 micro m 0.157 mil
(Note) In case of an average sampling rate of 64 times.
(Note)Value calculated with the linear output allowance factor (plus or minus 3 sigma) when connected to the controller included in the calculation of the detection width.
(Note:This value was obtained by converting the range of linear output fluctuation (plus or minus 3 sigma) into a sensing width, assuming that the smallest sensing object blocks the beam at the approximate center of the beam diameter of ø1 mm ø0.039 in.)


■■【In the case of (500 to 2,000 mm 19.685 to 78.74 in)】■■
Sensing width:
ø1 to ø2.5 mm ø0.039 to ø0.098 in

Min. sensing object:
ø50 micro m ø1.969 mil opaque object
Repeatability (During the state in which light is half blocked): -

Linear output resolution: -
-
Green LED (lights up during laser emission)Two units of sensors can be mounted close together. (When the controller interference prevention function is used)
design engineersPanasonicHL-T1010A
Sensing width 10 mm 0.394 in typeEMC Directive, RoHS DirectiveHL-AC1, HL-AC1P■■【In the case of(0 to 500 mm 0 to 19.685 in)】■■
Sensing width:
ø1 mm ø0.039 in

Min. sensing object:
ø8 micro m ø0.315 mil opaque object

Repeatability (During the state in which light is half blocked):
4 micro m 0.157 mil
(Note:In case of an average sampling rate of 64 times.)

Linear output resolution:
4 micro m 0.157 mil
(Note) In case of an average sampling rate of 64 times.
(Note)Value calculated with the linear output allowance factor (plus or minus 3 sigma) when connected to the controller included in the calculation of the detection width.
(Note:This value was obtained by converting the range of linear output fluctuation (plus or minus 3 sigma) into a sensing width, assuming that the smallest sensing object blocks the beam at the approximate center of the beam diameter of ø1 mm ø0.039 in.)


■■【In the case of (500 to 2,000 mm 19.685 to 78.74 in)】■■
Sensing width:
ø1 to ø2.5 mm ø0.039 to ø0.098 in

Min. sensing object:
ø50 micro m ø1.969 mil opaque object
Repeatability (During the state in which light is half blocked): -

Linear output resolution: -
-
Green LED (lights up during laser emission)Two units of sensors can be mounted close together. (When the controller interference prevention function is used)
design engineersPanasonicHL-AC1P
PNP outputEMC Directive, RoHS Directiven/an/an/an/a
design engineersPanasonicHL-T1010F
Sensing width 10 mm 0.394 in typeEMC Directive, RoHS DirectiveHL-AC1, HL-AC1P■■【In the case of(0 to 500 mm 0 to 19.685 in)】■■
Sensing width:
ø1 mm ø0.039 in

Min. sensing object:
ø8 micro m ø0.315 mil opaque object

Repeatability (During the state in which light is half blocked):
4 micro m 0.157 mil
(Note:In case of an average sampling rate of 64 times.)

Linear output resolution:
4 micro m 0.157 mil
(Note) In case of an average sampling rate of 64 times.
(Note)Value calculated with the linear output allowance factor (plus or minus 3 sigma) when connected to the controller included in the calculation of the detection width.
(Note:This value was obtained by converting the range of linear output fluctuation (plus or minus 3 sigma) into a sensing width, assuming that the smallest sensing object blocks the beam at the approximate center of the beam diameter of ø1 mm ø0.039 in.)


■■【In the case of (500 to 2,000 mm 19.685 to 78.74 in)】■■
Sensing width:
ø1 to ø2.5 mm ø0.039 to ø0.098 in

Min. sensing object:
ø50 micro m ø1.969 mil opaque object
Repeatability (During the state in which light is half blocked): -

Linear output resolution: -
-
Green LED (lights up during laser emission)Two units of sensors can be mounted close together. (When the controller interference prevention function is used)