Part Number List

Results 40
Models table for series Cylindrical Compact Inductive Proximity Sensor GX
Part No.DatasheetCE Marking Directive ComplianceMax. operation distanceStable sensing rangeStandard sensing objectHysteresisRepeatabilitySupply voltageCurrent consumptionOutputOutput:Utilization categoryOutput:Output operationOutput:Short-circuit protectionMax. response frequencyOperation indicatorProtectionAmbient TemperatureAmbient HumidityVoltage withstandabilityInsulation resistanceVibration resistanceShock resistanceSensing range variation:Temperature characteristicsSensing range variation:Voltage characteristicsMaterialCableCable ExtensionWeight (Typ.)Accessories
EMC Directive, RoHS Directive
2 mm 0.079 in plus or minus 15 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
0 to 1.6 mm 0 to 0.063 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet
12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in
10 % or less of operation distance (with standard sensing object)
40 microm 1.575 mil or less
10 to 30 V DC Ripple P-P 10% or less
15 mA or less
NPN open-collector transistor
- Maximum sink current: 200 mA(Note)
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 200 mA sink current), 0.4 V or less (at 50 mA sink current)
(Note:The maximum sink current varies depending on the ambient temperature.)
DC-12 or DC-13
Normally open
Incorporated
500 Hz
Red LED (lights up when the output is ON)
IP67 (IEC)
-25 to + 70 ℃ -13 to +158℉,
Storage: -25 to +80 ℃ -13 to +176℉
35 to 95 % RH, Storage: 35 to 95 % RH
500 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions ten times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉: Within + 15/- 10 % of sensing range at +20 ℃ +68℉
Within ±2.5 % for plus or minus15 % fluctuation of the supply voltage
Enclosure: Brass (Nickel plated), Resin part: ABS
0.14 mm2 3-core
oil, heat and cold resistant
cabtyre cable, 3 m 9.843 ft long
Extension up to total 100 m 328.084 ft is possible with 0.14 mm2, or more, cable.
Net weight: 60 g approx.
(Note:The given weight of the threaded type includes the weight of nuts and toothed lock washers.)
Nut: 2 pcs.
Toothed lock washer: 1 pc.
EMC Directive, RoHS Directive
2 mm 0.079 in plus or minus 15 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
0 to 1.6 mm 0 to 0.063 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet
12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in
10 % or less of operation distance (with standard sensing object)
40 microm 1.575 mil or less
10 to 30 V DC Ripple P-P 10% or less
15 mA or less
NPN open-collector transistor
- Maximum sink current: 200 mA(Note)
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 200 mA sink current), 0.4 V or less (at 50 mA sink current)
(Note:The maximum sink current varies depending on the ambient temperature.)
DC-12 or DC-13
Normally closed
Incorporated
500 Hz
Red LED (lights up when the output is ON)
IP67 (IEC)
-25 to + 70 ℃ -13 to +158℉,
Storage: -25 to +80 ℃ -13 to +176℉
35 to 95 % RH, Storage: 35 to 95 % RH
500 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions ten times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉: Within + 15/- 10 % of sensing range at +20 ℃ +68℉
Within ±2.5 % for plus or minus15 % fluctuation of the supply voltage
Enclosure: Brass (Nickel plated), Resin part: ABS
0.14 mm2 3-core
oil, heat and cold resistant
cabtyre cable, 3 m 9.843 ft long
Extension up to total 100 m 328.084 ft is possible with 0.14 mm2, or more, cable.
Net weight: 60 g approx.
(Note:The given weight of the threaded type includes the weight of nuts and toothed lock washers.)
Nut: 2 pcs.
Toothed lock washer: 1 pc.
EMC Directive, RoHS Directive
2 mm 0.079 in plus or minus 15 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
0 to 1.6 mm 0 to 0.063 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet
12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in
10 % or less of operation distance (with standard sensing object)
40 microm 1.575 mil or less
10 to 30 V DC Ripple P-P 10% or less
15 mA or less
NPN open-collector transistor
- Maximum sink current: 200 mA(Note)
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 200 mA sink current), 0.4 V or less (at 50 mA sink current)
(Note:The maximum sink current varies depending on the ambient temperature.)
DC-12 or DC-13
Normally open
Incorporated
500 Hz
Red LED (lights up when the output is ON)
IP67 (IEC)
-25 to + 70 ℃ -13 to +158℉,
Storage: -25 to +80 ℃ -13 to +176℉
35 to 95 % RH, Storage: 35 to 95 % RH
500 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions ten times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉: Within + 15/- 10 % of sensing range at +20 ℃ +68℉
Within ±2.5 % for plus or minus15 % fluctuation of the supply voltage
Enclosure: Brass (Nickel plated), Resin part: ABS
Net weight: 60 g approx.
(Note:The given weight of the threaded type includes the weight of nuts and toothed lock washers.)
Nut: 2 pcs.
Toothed lock washer: 1 pc.
EMC Directive, RoHS Directive
0.8 mm 0.031 in plus or minus 15%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
0 to 0.6 mm 0 to 0.024 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 5 × 5 × t 1 mm 0.197 × 0.197 × t 0.039 in
15 % or less of operation distance (with standard sensing object)
20 microm 0.787 mil or less
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
15 mA or less
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 0.4 V or less (at 50 mA sink current)
DC-12 or DC-13
Normally open
-
1kHz
Red LED (lights up when the output is ON)
IP67 (IEC)
-25 to + 70 ℃ -13 to +158℉,
Storage: -25 to +80 ℃ -13 to +176℉
35 to 95 % RH, Storage: 35 to 95 % RH
500 V AC for one min. between all supply terminals connected together and enclosure
5 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
200 m/s2 acceleration (20 G approx.) in X, Y and Z directions ten times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉: Within ±20 % of sensing range at +20 ℃ +68℉
Within ±2 % for plus or minus10 % fluctuation of the supply voltage
Enclosure: Brass (Nickel plated) Resin part: TPX
Net weight: 30 g approx.
(Note) The given weight of the threaded type includes the weight of two nuts and one toothed lock washer.
Nut: 2 pcs.
Toothed lock washer: 2 pcs.
EMC Directive, RoHS Directive
1 mm 0.039 in plus or minus 15%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
0 to 0.8 mm 0 to 0.031 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 8 × 8 × t 1 mm 0.315 × 0.315 × t 0.039 in
10 % or less of operation distance (with standard sensing object)
8 microm 0.315 mil or less
10 to 30 V DC Ripple P-P 10% or less
15 mA or less
NPN open-collector transistor
- Maximum sink current: 200 mA(Note)
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 200 mA sink current), 0.4 V or less (at 50 mA sink current)
(Note:The maximum sink current varies depending on the ambient temperature.)
DC-12 or DC-13
Normally open
Incorporated
1kHz
Red LED (lights up when the output is ON)
IP67 (IEC)
-25 to + 70 ℃ -13 to +158℉,
Storage: -25 to +80 ℃ -13 to +176℉
35 to 95 % RH, Storage: 35 to 95 % RH
500 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions ten times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉: Within + 15/- 10 % of sensing range at +20 ℃ +68℉
Within ±2.5 % for plus or minus15 % fluctuation of the supply voltage
Enclosure: Brass (Nickel plated), Resin part: ABS
0.14 mm2 3-core
oil, heat and cold resistant
cabtyre cable, 3 m 9.843 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight: 60 g approx.
(Note:The given weight of the threaded type includes the weight of nuts and toothed lock washers.)
Nut: 2 pcs.
Toothed lock washer: 1 pc.
EMC Directive, RoHS Directive
1 mm 0.039 in plus or minus 15%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
0 to 0.8 mm 0 to 0.031 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 8 × 8 × t 1 mm 0.315 × 0.315 × t 0.039 in
10 % or less of operation distance (with standard sensing object)
8 microm 0.315 mil or less
10 to 30 V DC Ripple P-P 10% or less
15 mA or less
NPN open-collector transistor
- Maximum sink current: 200 mA(Note)
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 200 mA sink current), 0.4 V or less (at 50 mA sink current)
(Note:The maximum sink current varies depending on the ambient temperature.)
DC-12 or DC-13
Normally closed
Incorporated
1kHz
Red LED (lights up when the output is ON)
IP67 (IEC)
-25 to + 70 ℃ -13 to +158℉,
Storage: -25 to +80 ℃ -13 to +176℉
35 to 95 % RH, Storage: 35 to 95 % RH
500 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions ten times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉: Within + 15/- 10 % of sensing range at +20 ℃ +68℉
Within ±2.5 % for plus or minus15 % fluctuation of the supply voltage
Enclosure: Brass (Nickel plated), Resin part: ABS
Net weight: 60 g approx.
(Note:The given weight of the threaded type includes the weight of nuts and toothed lock washers.)
Nut: 2 pcs.
Toothed lock washer: 1 pc.
EMC Directive, RoHS Directive
1 mm 0.039 in plus or minus 15%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
0 to 0.8 mm 0 to 0.031 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 8 × 8 × t 1 mm 0.315 × 0.315 × t 0.039 in
10 % or less of operation distance (with standard sensing object)
8 microm 0.315 mil or less
10 to 30 V DC Ripple P-P 10% or less
15 mA or less
NPN open-collector transistor
- Maximum sink current: 200 mA(Note)
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 200 mA sink current), 0.4 V or less (at 50 mA sink current)
(Note:The maximum sink current varies depending on the ambient temperature.)
DC-12 or DC-13
Normally closed
Incorporated
1kHz
Red LED (lights up when the output is ON)
IP67 (IEC)
-25 to + 70 ℃ -13 to +158℉,
Storage: -25 to +80 ℃ -13 to +176℉
35 to 95 % RH, Storage: 35 to 95 % RH
500 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions ten times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉: Within + 15/- 10 % of sensing range at +20 ℃ +68℉
Within ±2.5 % for plus or minus15 % fluctuation of the supply voltage
Enclosure: Brass (Nickel plated), Resin part: ABS
0.15 mm2 3-core bending, oil and heat resistant cabtyre cable, 3 m 9.843 ft long
Net weight: 60 g approx.
(Note:The given weight of the threaded type includes the weight of nuts and toothed lock washers.)
Nut: 2 pcs.
Toothed lock washer: 2 pcs.
EMC Directive, RoHS Directive
0.8 mm 0.031 in plus or minus 15%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
0 to 0.6 mm 0 to 0.024 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 5 × 5 × t 1 mm 0.197 × 0.197 × t 0.039 in
15 % or less of operation distance (with standard sensing object)
20 microm 0.787 mil or less
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
15 mA or less
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 0.4 V or less (at 50 mA sink current)
DC-12 or DC-13
Normally open
-
1kHz
Red LED (lights up when the output is ON)
IP67 (IEC)
-25 to + 70 ℃ -13 to +158℉,
Storage: -25 to +80 ℃ -13 to +176℉
35 to 95 % RH, Storage: 35 to 95 % RH
500 V AC for one min. between all supply terminals connected together and enclosure
5 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
200 m/s2 acceleration (20 G approx.) in X, Y and Z directions ten times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉: Within ±20 % of sensing range at +20 ℃ +68℉
Within ±2 % for plus or minus10 % fluctuation of the supply voltage
Enclosure: Brass (Nickel plated) Resin part: TPX
0.1 mm2 3-core bending, oil and heat resistant cabtyre cable, 3 m 9.843 ft long
Net weight: 30 g approx.
(Note) The given weight of the threaded type includes the weight of two nuts and one toothed lock washer.
Nut: 2 pcs.
Toothed lock washer: 2 pcs.
EMC Directive, RoHS Directive
0.8 mm 0.031 in plus or minus 15%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
0 to 0.6 mm 0 to 0.024 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 5 × 5 × t 1 mm 0.197 × 0.197 × t 0.039 in
15 % or less of operation distance (with standard sensing object)
20 microm 0.787 mil or less
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
15 mA or less
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 0.4 V or less (at 50 mA sink current)
DC-12 or DC-13
Normally closed
-
1kHz
Red LED (lights up when the output is ON)
IP67 (IEC)
-25 to + 70 ℃ -13 to +158℉,
Storage: -25 to +80 ℃ -13 to +176℉
35 to 95 % RH, Storage: 35 to 95 % RH
500 V AC for one min. between all supply terminals connected together and enclosure
5 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
200 m/s2 acceleration (20 G approx.) in X, Y and Z directions ten times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉: Within ±20 % of sensing range at +20 ℃ +68℉
Within ±2 % for plus or minus10 % fluctuation of the supply voltage
Enclosure: Brass (Nickel plated) Resin part: TPX
Net weight: 30 g approx.
(Note) The given weight of the threaded type includes the weight of two nuts and one toothed lock washer.
Nut: 2 pcs.
Toothed lock washer: 1 pc.
EMC Directive, RoHS Directive
1 mm 0.039 in plus or minus 15%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
0 to 0.8 mm 0 to 0.031 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 6 × 6 × t 1 mm 0.236 × 0.236 × t 0.039 in
15 % or less of operation distance (with standard sensing object)
8 microm 0.315 mil or less
10 to 30 V DC Ripple P-P 10% or less
15 mA or less
NPN open-collector transistor
- Maximum sink current: 200 mA(Note)
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 200 mA sink current), 0.4 V or less (at 50 mA sink current)
(Note:The maximum sink current varies depending on the ambient temperature.)
DC-12 or DC-13
Normally closed
Incorporated
1.5kHz
Red LED (lights up when the output is ON)
IP67 (IEC)
-25 to + 70 ℃ -13 to +158℉,
Storage: -25 to +80 ℃ -13 to +176℉
35 to 95 % RH, Storage: 35 to 95 % RH
500 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions ten times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉: Within ±15 % of sensing range at +20 ℃ +68℉
Within ±2.5 % for plus or minus15 % fluctuation of the supply voltage
Enclosure: Brass (Nickel plated), Resin part: ABS
0.14 mm2 3-core
oil, heat and cold resistant
cabtyre cable, 3 m 9.843 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight: 55 g approx.
MS-SS5 (Sensor mounting bracket): 1 pc.