Wire-Saving Systems: S-LINK V gateway controller for open network

Model List

Found 3 matches. Display 1 - 3 matches.
Part No.sort descendingData SheetSupply voltageCurrent consumptionAllowable through currentS-LINK V side : Transmission speedS-LINK V side : Refresh timeS-LINK V side : I/O pointsS-LINK V side : Connected node No.S-LINK V side : Transmission distanceS-LINK V side : Total wiring lengthS-LINK V side : Transmission cableParts Inventory
   Column active Filter
Close

Filter by Supply voltage

Column active Filter
Close

Filter by Current consumption

Column active Filter
Close

Filter by Allowable through current

Column active Filter
Close

Filter by S-LINK V side : Transmission speed

Column active Filter
Close

Filter by S-LINK V side : Refresh time

Column active Filter
Close

Filter by S-LINK V side : I/O points

Column active Filter
Close

Filter by S-LINK V side : Connected node No.

Column active Filter
Close

Filter by S-LINK V side : Transmission distance

Column active Filter
Close

Filter by S-LINK V side : Total wiring length

Column active Filter
Close

Filter by S-LINK V side : Transmission cable

 
design engineersPanasonicSL-VGU1-D
24V DC+10-5%300mA or less (excluding error output load and power supply for driving I/O units)
Note : The current consumption value shown here is the total of the maximum current (D-G line only) supplied to the S-LINK V I/O units and the current consumption of the S-LINK V gateway controller.
7A
Note : This product is not equipped with any short-circuit protective function. For this reason, select a power supply unit having short-circuit protective function (fuse, etc.).
A mode: 110kbps, B mode: 27.5kbps, C mode: 6.9kbpsA mode: 0.29 to 10.32ms, B mode: 1.18 to 41.29ms, C mode: 4.70 to 165.15ms512 points max.256 nodes max.A mode: 50m max., B mode: 200m max., C mode: 800m max.A mode: 100m or less, B mode: 400m or less, C mode: 1,600m or lessExclusive 4-core flat cable(0.5mm2) or Conductor cross-section area 0.3 to 2.0mm2 4-core VCTF cable (without shield)
Note : The VCTF cable is the vinyl cabtyre cable that conforms to the requirements of JIS C 3306 "Polyvinyl chloride insulated flexible cords."
design engineersPanasonicSL-VGU1-C
24V DC+10-5%300mA or less (excluding error output load and power supply for driving I/O units)
Note : The current consumption value shown here is the total of the maximum current (D-G line only) supplied to the S-LINK V I/O units and the current consumption of the S-LINK V gateway controller.
7A
Note : This product is not equipped with any short-circuit protective function. For this reason, select a power supply unit having short-circuit protective function (fuse, etc.).
A mode: 110kbps, B mode: 27.5kbps, C mode: 6.9kbpsA mode: 0.29 to 10.32ms, B mode: 1.18 to 41.29ms, C mode: 4.70 to 165.15msBuffer memory assignment pattern 1: 128 inputs max., 128 outputs max. (Note 1)
Buffer memory assignment pattern 2: 256 inputs max., 256 outputs max. (Note 2)
Note 1 : In case of buffer memory assignment pattern 1, 112 channels are assigned to remote I/O (RX / RY) and the balance 16 channels are assigned to remote register (RWrm / RWwm).
Note 2 : If buffer memory assignment pattern 2 is used, all the points will be assigned to the remote registers (RWrm / RWwm).
256 nodes max.A mode: 50m max., B mode: 200m max., C mode: 800m max.A mode: 100m or less, B mode: 400m or less, C mode: 1,600m or lessExclusive 4-core flat cable (0.5mm2) or Conductor cross-section area 0.3 to 2.0mm2 4-core VCTF cable (without shield)
Note : The VCTF cable is the vinyl cabtyre cable that conforms to the requirements of JIS C 3306 "Polyvinyl chloride insulated flexible cords."
design engineersPanasonicSL-VGU1-EC
24V DC+10-5%300 mA or less
(excluding error output load and power supply for driving I/O units)
Note : The current consumption value shown here is the total of the maximum current (D-G line only) supplied to the S-LINK V I/O units and the current consumption of the S-LINK V gateway controller.
7A
Note : This product is not equipped with any short-circuit protective function. For this reason, select a power supply unit having short-circuit protective function (fuse, etc.).
A mode: 110 kbps, B mode: 27.5 kbps, C mode: 6.9 kbpsA mode: 0.29 to 10.32 ms, B mode: 1.18 to 41.29 ms, C mode: 4.70 to 165.15 msMax. 512 pointsMax. 256 nodesA mode: 50 m 164 ft max., B mode: 200 m 656 ft max., C mode: 800 m 2,625 ft max.A mode: 100 m 328 ft or less, B mode: 400 m 1,312 ft or less, C mode: 1,600 m 5,249 ft or lessExclusive 4-core flat cable (0.5 mm2) or conductor cross-section area 0.3 to 2.0 mm2 4-core VCTF cable (without shield)
Note : The VCTF cable is the vinyl cabtyre cable that conforms to the requirements of JIS C 3306 "Polyvinyl chloride insulated flexible cords."