Specification

Specifications table for model FX-551L3-P-J
ItemPerformance characteristics
Directive ComplianceEMC Directive, RoHS Directive
Supply Voltage 12 to 24 V DC +10-15% Ripple P-P 10 % or less
Power ConsumptionNormal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage)
ECO mode: 720 mW or less (current consumption 30 mA or less at 24 V supply voltage)
Communication Output (C/Q): IO-Link CommunicationIO-Link Specification V1.1
(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
Communication Output (C/Q): Baud RateCOM3 (230.4 kbps)
(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
Communication Output (C/Q): Process Data4 byte
(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
Communication Output (C/Q): Minimum Cycle Time1.0 ms
(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
Control Output (DO)PNP open-collector transistor
• Maximum source current: 50 mA
• Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 2 V or less (Note) (at maximum source current)
(Note:)In case of using the cable (cable length 2 m 6.562 ft).
Control Output (DO): Output OperationSwitchable either Light-ON or Dark-ON by L/D mode
Control Output (DO): Short-Circuit ProtectionIncorporated
Response TimeSTD: 250 μs or less, LONG: 2 ms or less, U-LG: 4 ms or less, HYPR: 24 ms or less, selectable
Sensitivity Setting2-point teaching / Limit teaching / Full-auto teaching / Manual adjustment
Incident Light Sensitivity SettingIncorporated, 4 steps
Incident Light Intensity Display RangeSTD: 0 to 4,000, LONG: 0 to 8,000, U-LG / HYPR: 0 to 9,999
Timer Function Incorporated with variable OFF-delay / ON-delay / One-shot, switchable either effective or ineffective
Timer Function: Timer Period0.1 to 999.9 ms approx., in units of 0.1 ms approx.
Different Frequency Interference Prevention FunctionIncorporated (up to 4 units). Note that the response time varies depending on the setting.
F-1: 0.8 ms or less, F-2: 0.9 ms or less, F-3: 1.0 ms or less, F-4: 1.7 ms or less
(Note:)This function increases the hysteresis. Check the sensing condition when using the function.
ProtectionIP40 (IEC)
Ambient Temperature-10 to +55℃ +14 to +131℉ (If 4 to 7 units are mounted in cascade: -10 to +50℃ +14 to +122℉ or if 8 to 16 units are mounted in cascade: -10 to +45℃ +14 to +113℉) (No dew condensation or icing allowed), Storage: -20 to +70℃ -4 to +158℉
Emitting Element (Modulated)Red LED (Peak emission wavelength: 660 nm 0.026 mil)
MaterialEnclosure, Case cover: Polycarbonate, Switch: Polyacetal
Cable0.2 mm2 cabtyre cable with M12 connector, 0.3 m 0.984 ft long
Cable ExtensionExtension up to total 20 m 65.617 ft is possible with 0.3 mm2, or more, cable.
(Condition of CE compliance: less tan 20 m 65.617 ft) (however, supply voltage 12 V DC or more)
Weight (Typ.)Net weight: 35 g approx., Gross weight: 60 g approx.
RemarkWhere measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23℃ +73.4℉.
Vibration Resistance10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
Shock Resistance98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each

Stock Check