Specification

Specifications table for model SC-GU3-04
ItemPerformance characteristics
Supply Voltage 24 V DC +10-15 % Ripple P-P 10 % or less
Current Consumption200 mA or less (without connected sensor amplifiers)
Communication MethodCC-Link IE Field
Station No. Setting1 to 120 (decimal) (0 and 121 or higher result in an error)
Remote Station TypeRemote device station
Ambient Temperature–10 to +50 ℃ +14 to +122 ℉ (8 to 16 units connected: –10 to +45 ℃ +14 to +113 ℉) (No dew condensation or icing allowed)Storage: –20 to +70 ℃ –4 to +158 ℉
Ambient Humidity35 to 85 % RH, Storage: 35 to 85 % RH
MaterialEnclosure: Polycarbonate
CE Marking Directive ComplianceEMC Directive(Note), RoHS Directive(Note:Ground the shield wire of the Ethernet cable at a higher-level device in order to comply with the EMC Directive. This product is not provided with a grounding terminal.)
Compatible Sensor UnitsSensor amplifiers (NPN output type) that can connect to the SC‑71 cascading connector unit (optional)
Number of Units ConnectableMaximum of 16 units per SC-GU3-04 unit(Max. 12 units when FX-500 / LS-500 series are connected)
Network No. Setting 1 to 239 (decimal) [1 to EF (hex)] (0 and 240 or higher result in an error) (Note:For the Network No. setting of this product, set a value converted to hexadecimal.)
Communication Speed1 Gbps
Maximum Overall Cable Distance 100 m 328.084 ft
Allowable Through Current2A or less (Note:Be sure to check that total current consumption of sensor amplifiers connected in cascade does not exceed allowable passing current.)
Transmission Line Types Line, star (mixing of line and star types is possible), ring
Net Weight 100 g approx.

Stock Check