Specifications
Item | Performance characteristics |
---|---|
Directive Compliance | EMC Directive, RoHS Directive |
Number of Connectable Units | Maximum of 16 units per SC-GU3-01 unit (Max. 12 units when FX-500 / LS-500 series are connected) (Max. 12 units when FX-500 / LS-500 series are connected) |
Supply Voltage | 24V DC +10/-15% Ripple P-P 10 % or less |
Current Consumption | 120 mA or less (without connected sensor amplifiers) |
Allowable Passing Current | Wire-saving connector 2 A (Note 1), supply connector 6 A (Note 2) (Note 1) Be sure to check that total current consumption of sensor amplifiers connected in cascade does not exceed allowable passing current. (Note 2) In case of supplying power to other devices, be sure to set the current less than allowable passing current. |
Communication Method | CC-Link Ver.1.10 |
Number of Occupied Station | Switchable 1 or 4 station |
Baud Rate / Total Extension Length | 10Mbps / 100m 328.084 ft 5Mbps / 150m 492.126 ft 2.5Mbps / 200m 656.168 ft 625kbps / 600m 1968.504 ft 156kbps / 1,200m 3937.008 ft |
Communication Cable | Specified cable (twist pair cable with shield) (Note) Use only a special-use communication cable that is approved by the CC-Link Partner Association. |
Station No. Setting | 1 to 64 (0 and 65 or more: Error) |
Remote Station Type | Remote device station |
Ambient Temperature | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), (If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉, if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉) Storage: –20 to +70 ℃ –4 to +158 ℉ |
Ambient Humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Material | Enclosure: Polycarbonate |
Weight (Typ.) | Net weight: 80 g approx. Gross weight: 120 g approx. |