Specifications

Specifications table for model SC-GU3-01
ItemPerformance characteristics
Directive ComplianceEMC Directive, RoHS Directive
Number of Connectable UnitsMaximum of 16 units per SC-GU3-01 unit
(Max. 12 units when FX-500 / LS-500 series are connected) (Max. 12 units when FX-500 / LS-500 series are connected)
Supply Voltage 24V DC +10/-15% Ripple P-P 10 % or less
Current Consumption120 mA or less (without connected sensor amplifiers)
Allowable Passing CurrentWire-saving connector 2 A (Note 1), supply connector 6 A (Note 2)
(Note 1) Be sure to check that total current consumption of sensor amplifiers connected in cascade does not exceed allowable passing current.
(Note 2) In case of supplying power to other devices, be sure to set the current less than allowable passing current.
Communication MethodCC-Link Ver.1.10
Number of Occupied StationSwitchable 1 or 4 station
Baud Rate / Total Extension Length10Mbps / 100m 328.084 ft
5Mbps / 150m 492.126 ft
2.5Mbps / 200m 656.168 ft
625kbps / 600m 1968.504 ft
156kbps / 1,200m 3937.008 ft
Communication CableSpecified cable (twist pair cable with shield)
(Note) Use only a special-use communication cable that is approved by the CC-Link Partner Association.
Station No. Setting1 to 64 (0 and 65 or more: Error)
Remote Station TypeRemote device station
Ambient Temperature–10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
(If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉,
if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉)
Storage: –20 to +70 ℃ –4 to +158 ℉
Ambient Humidity35 to 85 % RH, Storage: 35 to 85 % RH
MaterialEnclosure: Polycarbonate
Weight (Typ.)Net weight: 80 g approx.
Gross weight: 120 g approx.

Stock check

Model image for SC-GU3-01

SC-GU3-01