Specifications
Item | Performance characteristics |
---|---|
Directive Compliance | EMC Directive, RoHS Directive |
Number of Connectable Units | Maximum of 16 units per SC-GU3-01 unit (Max. 12 units when FX-500 / LS-500 series are connected) |
Supply Voltage | 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
Current Consumption | 80 mA or less (at 24 V) (without connected sensor amplifiers) |
Allowable Passing Current | Wire-saving connector 2 A (Note) Be sure to check that total current consumption of sensor amplifiers connected in cascade does not exceed allowable passing current. |
Compliance Standard | IEEE802.3u |
Baud Rate | 100 Mbps |
Communication Cable | Category 5e |
Internodal Distance | 100 m 328.1ft |
Communication Ports | RJ45 × 2 |
EtherCAT Communication Standards | Process data communication, Mailbox communication |
Ambient Temperature | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), (If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉, if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉) Storage: –20 to +70 ℃ –4 to +158 ℉ |
Ambient Humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Material | Enclosure: Polycarbonate |
Weight (Typ.) | Net weight: 75 g approx. Gross weight: 120 g approx. |