Specification

Specifications table for model SC-GU3-02
ItemPerformance characteristics
Directive ComplianceEMC Directive, RoHS Directive
Number of Connectable UnitsMaximum of 16 units per SC-GU3-02 unit
(Max. 12 units when FX-500 / LS-500 series are connected) (Max. 12 units when FX-500 / LS-500 series are connected)
Supply Voltage 11 to 25 V DC Ripple P-P 10 % or less
Current Consumption100 mA or less (without connected sensor amplifiers)
Allowable Passing CurrentWire-saving connector 2A
(Note) Be sure to check that total current consumption of sensor amplifiers connected in cascade does not exceed allowable passing current.
Communication MethodDeviceNet compliant
Baud Rate / Total Extension Length500kbps / 100m 328.084 ft (thick cable) 100m 328.084 ft (thin cable)
250kbps / 250m 820.21 ft (thick cable) 100m 328.084 ft (thin cable)
125kbps / 500m 1640.42 ft (thick cable) 100m 328.084 ft (thin cable)
Communication CableComplies with DeviceNet standards
(Note) Use a special cable for DeviceNet that complies with the DeviceNet standards.
Address Setting0 to 63 (64 or more: Error)
Supported FunctionsI/O communication (Poll), Explicit message communication
Ambient Temperature–10 to +55 ℃ +14 to +131 ℉ (No dew ondensation or icing allowed),
(If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉,
if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉)
Storage: –20 to +70 ℃ –4 to +158 ℉
Ambient Humidity35 to 85 % RH, Storage: 35 to 85 % RH
MaterialEnclosure: Polycarbonate
Weight (Typ.)Net weight: 75 g approx.
Gross weight: 120 g approx.

Stock Check