Item | Performance characteristics |
---|---|
Supply Voltage | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less (By power supplied from the SC-GU2-C.) |
Current Consumption | Max. 25 mA or less (when all indicators light up) (Note) The current consumption and input current of output device connected are not included. |
Ambient Temperature | -10 to +55 degrees +14 to +131 degrees Fahrenheit (If 4 to 7 units are connected in cascade: -10 to +50 degrees +14 to +122 degrees Fahrenheit , if 8 to 16 units are connected in cascade: -10 to +45 degrees +14 to +113degrees Fahrenheit ) (No dew condensation or icing allowed), Storage: -10 to +70 degrees +14 to +158 degrees Fahrenheit |
Ambient Humidity | 35 to 85 % RH, Storage: 35 to 85 % |
Material | Enclosure: Heat-resistant ABS |
Weight (Typ.) | Net weight: 20 g approx. Gross weight: 40 g approx. |
Accessory | Connector (e-CON): 1 pc. |
Power Indicator | Green LED (lights up when the power is ON) |