Specifications

Specifications table for model GX-12MLUB-C5
ItemPerformance characteristics
Max. Operation Distance8 mm 0.315 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
Stable Sensing Range0 to 6.4 mm 0 to 0.252 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Standard Sensing Object Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in
Hysteresis20 % or less of operation distance (with standard sensing object)
Supply Voltage 12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
Current Consumption0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
OutputNon-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Output: Short-Circuit ProtectionIncorporated
Max. Response Frequency650 Hz
Operation Indicator Orange LED (lights up when the output is ON)
ProtectionIP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
Ambient Temperature-25 to +70 ℃ -13 to +158℉,
Storage: -30 to +80 ℃ -22 to +176℉
Ambient Humidity45 to 85 % RH, Storage: 35 to 95 % RH
Voltage Withstandability1,000 V AC for one min.
between all supply terminals connected together and enclosure
Insulation Resistance50 MΩ, or more, with 250 V DC megger
between all supply terminals connected together and enclosure
Vibration Resistance10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
Shock Resistance1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Sensing Range Variation: Temperature Characteristics Over ambient temperature range -25 to +70 ℃ -13 to +158℉
: within plus or minus10 % of sensing range at +20 ℃ +68℉
Sensing Range Variation: Voltage Characteristics Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
MaterialEnclosure: Brass (Nickel plated)
Sensing part: Nylon
Indicator part: Nylon
AccessoriesNut: 2 pcs., Toothed lock washer: 1 pc.

Stock check

Model image for GX-12MLUB-C5

GX-12MLUB-C5