Compact Photoelectric Sensor CX-400 Ver.2

For the CX-400 Series, the user has a large selection of ultra compact Photoelectric Sensors at his disposal. The Series includes three thru-beam, five retro-reflective, four diffuse reflective and four trigonometric types with foreground/background suppression. With its new ASIC (application specific integrated circuit), the Sensors require up to 60% less energy than before.

Characteristics

  • Three Thru-Beam, Five Retro-Reflective, Eight Reflective Types
  • Light ON/Dark ON Modes
  • Short-Circuit Protected
  • IP67 Degree Of Protection
  • Up To 60% Less Power Consumption

Part Number List

Results 168
Models table for series Compact Photoelectric Sensor CX-400 Ver.2
Part No.DatasheetCE Marking Directive ComplianceAdjustable RangeSensing Range Sensing Range (With White Non-Glossy Paper)Sensing Object Repeatability (Perpendicular to Sensing Axis) HysteresisRepeatabilitySupply Voltage Current ConsumptionOutputOutput: Output Operation Output: Short-Circuit ProtectionResponse TimeOperation Indicator Stability IndicatorPower Indicator Sensitivity AdjusterSensing ModeDistance AdjusterAutomatic Interference Prevention FunctionProtectionAmbient TemperatureAmbient HumidityAmbient IlluminanceVoltage WithstandabilityInsulation Resistance Vibration ResistanceShock ResistanceEmitting Element (Modulated)Emitting Element (Modulated): Peak Emission WavelengthSpot Diameter MaterialCableCable ExtensionAccessory
EMC Directive, RoHS Directive
20 to 50 mm 0.787 to 1.969 in
(Note) The adjustable range stands for the maximum sensing range which can be set with the distance adjuster. The sensor can detect an object 2 mm 0.079 in [CX-444(-P): 15 mm 0.591 in, CX-442(-P): 20 mm 0.787 in], or more, away.
2 to 50 mm 0.079 to 1.969 in
2 % or less of operation distance(with white non-glossy paper)
Along sensing axis: 1 mm 0.039 in or less, Perpendicular to sensing axis: 0.2 mm 0.008 in or less (with white non-glossy paper)
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
20 mA or less
PNP open-collector transistor
- Maximum source current: 100 mA
- Applied voltage: 30 V DC or less (between output and +V)
- Residual voltage: 2 V or less (at 100 mA source current), 1 V or less (at 16 mA source current)
Switchable either Detection-ON or Detection-OFF
Incorporated
1 ms or less
Orange LED (lights up when the output is ON)
Green LED(lights up under stable operating condition)
BGS / FGS functions switchable with wiring of sensing mode selection input
5-turn mechanical adjuster
Incorporated
(Note) Note that detection may be unstable depending on the mounting conditions or the sensing object. In the state that this product is mounted, be sure to check the operation with the actual sensing object.
IP67 (IEC)
- 25 to +55℃ -13 to +131℃ ℉ (No dew condensation or icing allowed ), Storage: -30 to +70℃ -22 to +158℃ ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 3 mm 0.118 in amplitude in X, Y and Z directions for two hours each
500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each
Red LED
650 nm 0.026 mil
Ø6.5 mm Ø0.256 in approx.(at 50 mm 1.969 in distance)
Enclosure: PBT (Polybutylene terephthalate)
Front cover: Polycarbonate
Indicator cover: Polycarbonate
EMC Directive, RoHS Directive
15 m 49.213 ft
Ø12 mm Ø0.472 in or more opaque object
(Note) If slit masks (optional) are fitted, an object of Ø0.5 mm Ø0.020 in (using round slit mask) can be detected.
0.5 mm 0.020 in or less
-
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Emitter: 20 mA or less
Receiver: 10 mA or less
PNP open-collector transistor
- Maximum source current: 100 mA
- Applied voltage: 30 V DC or less (between output and +V)
- Residual voltage: 2 V or less (at 100 mA source current), 1 V or less (at 16 mA source current)
Incorporated
1 ms or less
Orange LED(lights up when the output is ON)
(incorporated on the receiver for thru-beam type)
Green LED(lights up under stable light received condition or stable dark condition)
(incorporated on the receiver for thru-beam type)
Green LED(lights up when the power is ON)
(incorporated on the emitter)
-
-
IP67 (IEC)
- 25 to +55℃ -13 to +131℃ ℉ (No dew condensation or icing allowed ), Storage: -30 to +70℃ -22 to +158℃ ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each
Infrared LED
870 nm 0.034 mil
Enclosure: PBT (polybutylene terephthalate)
Lens: acrylic
Indicator cover: acrylic
0.2 mm23-core (emitter: 2-core) cabtyre cable, 0.5 m 1.640 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (both emitter and receiver).
EMC Directive, RoHS Directive
10 m 32.808 ft
Ø12 mm Ø0.472 in or more opaque object
(Note) If slit masks (optional) are fitted, an object of Ø0.5 mm Ø0.020 in (using round slit mask) can be detected.
0.5 mm 0.020 in or less
-
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Emitter: 15 mA or less
Receiver: 10 mA or less
PNP open-collector transistor
- Maximum source current: 100 mA
- Applied voltage: 30 V DC or less (between output and +V)
- Residual voltage: 2 V or less (at 100 mA source current), 1 V or less (at 16 mA source current)
Incorporated
1 ms or less
Orange LED(lights up when the output is ON)
(incorporated on the receiver for thru-beam type)
Green LED(lights up under stable light received condition or stable dark condition)
(incorporated on the receiver for thru-beam type)
Green LED(lights up when the power is ON)
(incorporated on the emitter)
-
Two units of sensors can be mounted close together with interference prevention filters. (Sensing range: 5 m 16.404 ft)
IP67 (IEC)
- 25 to +55℃ -13 to +131℃ ℉ (No dew condensation or icing allowed ), Storage: -30 to +70℃ -22 to +158℃ ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each
Red LED
680 nm 0.027 mil
Enclosure: PBT (polybutylene terephthalate)
Lens: acrylic
Indicator cover: acrylic
0.2 mm23-core (emitter: 2-core) cabtyre cable, 0.5 m 1.640 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (both emitter and receiver).
EMC Directive, RoHS Directive
3 m 9.843 ft
(Note) The sensing range and the sensing object of the retroreflective type sensor are specifi ed for the RF-230 reflector. The sensing range represents the actual sensing range of the sensor.
Ø50 mm Ø1.969 in or more opaque, translucent or specular object
(Note) The sensing range and the sensing object of the retroreflective type sensor are specifi ed for the RF-230 reflector. The sensing range represents the actual sensing range of the sensor.
(Note) Make sure to confirm detection with an actual sensor before use.
0.5 mm 0.020 in or less
-
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
13 mA or less
PNP open-collector transistor
- Maximum source current: 100 mA
- Applied voltage: 30 V DC or less (between output and +V)
- Residual voltage: 2 V or less (at 100 mA source current), 1 V or less (at 16 mA source current)
Switchable either Light-ON or Dark-ON
Incorporated
1 ms or less
Orange LED(lights up when the output is ON)
(incorporated on the receiver for thru-beam type)
Green LED(lights up under stable light received condition or stable dark condition)
(incorporated on the receiver for thru-beam type)
-
Continuously variable adjuster(incorporated on the receiver for thru-beam type)
Incorporated(Two units of sensors can be mounted close together.)
IP67 (IEC)
- 25 to +55℃ -13 to +131℃ ℉ (No dew condensation or icing allowed ), Storage: -30 to +70℃ -22 to +158℃ ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each
Red LED
680 nm 0.027 mil
Enclosure: PBT (polybutylene terephthalate)
Lens: acrylic
Indicator cover: acrylic
EMC Directive, RoHS Directive
3 m 9.843 ft
(Note) The sensing range and the sensing object of the retroreflective type sensor are specifi ed for the RF-230 reflector. The sensing range represents the actual sensing range of the sensor.
Ø50 mm Ø1.969 in or more opaque, translucent or specular object
(Note) The sensing range and the sensing object of the retroreflective type sensor are specifi ed for the RF-230 reflector. The sensing range represents the actual sensing range of the sensor.
(Note) Make sure to confirm detection with an actual sensor before use.
0.5 mm 0.020 in or less
-
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
13 mA or less
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current)
Switchable either Light-ON or Dark-ON
Incorporated
1 ms or less
Orange LED(lights up when the output is ON)
(incorporated on the receiver for thru-beam type)
Green LED(lights up under stable light received condition or stable dark condition)
(incorporated on the receiver for thru-beam type)
-
Continuously variable adjuster(incorporated on the receiver for thru-beam type)
Incorporated(Two units of sensors can be mounted close together.)
IP67 (IEC)
- 25 to +55℃ -13 to +131℃ ℉ (No dew condensation or icing allowed ), Storage: -30 to +70℃ -22 to +158℃ ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each
Red LED
680 nm 0.027 mil
Enclosure: PBT (polybutylene terephthalate)
Lens: acrylic
Indicator cover: acrylic
0.2 mm23-core cabtyre cable, 0.5 m 1.640 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
EMC Directive, RoHS Directive
5 m 16.404 ft
(Note) The sensing range and the sensing object of the retroreflective type sensor are specifi ed for the RF-230 reflector. The sensing range represents the actual sensing range of the sensor.
Ø50 mm Ø1.969 in or more opaque or translucent object
(Note) The sensing range and the sensing object of the retroreflective type sensor are specifi ed for the RF-230 reflector. The sensing range represents the actual sensing range of the sensor.
(Note) Make sure to confirm detection with an actual sensor before use.
0.5 mm 0.020 in or less
-
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
10 mA or less
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current)
Switchable either Light-ON or Dark-ON
Incorporated
1 ms or less
Orange LED(lights up when the output is ON)
(incorporated on the receiver for thru-beam type)
Green LED(lights up under stable light received condition or stable dark condition)
(incorporated on the receiver for thru-beam type)
-
Continuously variable adjuster(incorporated on the receiver for thru-beam type)
Incorporated(Two units of sensors can be mounted close together.)
IP67 (IEC)
- 25 to +55℃ -13 to +131℃ ℉ (No dew condensation or icing allowed ), Storage: -30 to +70℃ -22 to +158℃ ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each
Red LED
650 nm 0.026 mil
Enclosure: PBT (polybutylene terephthalate)
Lens: acrylic
Indicator cover: acrylic
0.2 mm23-core cabtyre cable, 5 m 16.404 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
EMC Directive, RoHS Directive
50 to 1,000mm 1.969 to 39.37 in
(Note) The sensing range and the sensing object of the retroreflective type sensor are specifi ed for the RF-230 reflector. The sensing range represents the actual sensing range of the sensor.
Ø50 mm Ø1.969 in or more transparent,translucent or opaque object
(Note) The sensing range and the sensing object of the retroreflective type sensor are specifi ed for the RF-230 reflector. The sensing range represents the actual sensing range of the sensor.
(Note) Make sure to confirm detection with an actual sensor before use.
0.5 mm 0.020 in or less
-
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
10 mA or less
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current)
Switchable either Light-ON or Dark-ON
Incorporated
1 ms or less
Orange LED(lights up when the output is ON)
(incorporated on the receiver for thru-beam type)
Green LED(lights up under stable light received condition or stable dark condition)
(incorporated on the receiver for thru-beam type)
-
Continuously variable adjuster(incorporated on the receiver for thru-beam type)
Incorporated(Two units of sensors can be mounted close together.)
IP67 (IEC)
- 25 to +55℃ -13 to +131℃ ℉ (No dew condensation or icing allowed ), Storage: -30 to +70℃ -22 to +158℃ ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each
Infrared LED
870 nm 0.034 mil
Enclosure: PBT (polybutylene terephthalate)
Lens: polycarbonate
Indicator cover: polycarbonate
0.2 mm23-core cabtyre cable, 0.5 m 1.640 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
RF-230 (Reflector): 1 pc.
EMC Directive, RoHS Directive
0.1 to 2 m 0.328 to 6.562 ft
(Note) The sensing range and the sensing object of the retroreflective type sensor are specifi ed for the RF-230 reflector. The sensing range represents the actual sensing range of the sensor.
Ø50 mm Ø1.969 in or more transparent,translucent or opaque object
(Note) The sensing range and the sensing object of the retroreflective type sensor are specifi ed for the RF-230 reflector. The sensing range represents the actual sensing range of the sensor.
(Note) Make sure to confirm detection with an actual sensor before use.
0.5 mm 0.020 in or less
-
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
10 mA or less
PNP open-collector transistor
- Maximum source current: 100 mA
- Applied voltage: 30 V DC or less (between output and +V)
- Residual voltage: 2 V or less (at 100 mA source current), 1 V or less (at 16 mA source current)
Switchable either Light-ON or Dark-ON
Incorporated
1 ms or less
Orange LED(lights up when the output is ON)
(incorporated on the receiver for thru-beam type)
Green LED(lights up under stable light received condition or stable dark condition)
(incorporated on the receiver for thru-beam type)
-
Continuously variable adjuster(incorporated on the receiver for thru-beam type)
Incorporated(Two units of sensors can be mounted close together.)
IP67 (IEC)
- 25 to +55℃ -13 to +131℃ ℉ (No dew condensation or icing allowed ), Storage: -30 to +70℃ -22 to +158℃ ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each
Infrared LED
870 nm 0.034 mil
Enclosure: PBT (polybutylene terephthalate)
Lens: polycarbonate
Indicator cover: polycarbonate
0.2 mm23-core cabtyre cable, 0.5 m 1.640 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
RF-230 (Reflector): 1 pc.
EMC Directive, RoHS Directive
100 mm 3.937 in
(Note) The sensing range and hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 × 200 mm 7.874 × 7.874 in) as the object.
Opaque, translucent or transparent object
(Note) Make sure to confirm detection with an actual sensor before use.
1 mm 0.039 in or less
15 % or less of operation distance
(Note) The sensing range and hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 × 200 mm 7.874 × 7.874 in) as the object.
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
13 mA or less
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current)
Switchable either Light-ON or Dark-ON
Incorporated
1 ms or less
Orange LED(lights up when the output is ON)
(incorporated on the receiver for thru-beam type)
Green LED(lights up under stable light received condition or stable dark condition)
(incorporated on the receiver for thru-beam type)
-
Continuously variable adjuster(incorporated on the receiver for thru-beam type)
Incorporated(Two units of sensors can be mounted close together.)
IP67 (IEC)
- 25 to +55℃ -13 to +131℃ ℉ (No dew condensation or icing allowed ), Storage: -30 to +70℃ -22 to +158℃ ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each
Infrared LED
860 nm 0.034 mil
Enclosure: PBT (polybutylene terephthalate)
Lens: acrylic
Indicator cover: acrylic
0.2 mm23-core cabtyre cable, 5 m 16.404 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
-
EMC Directive, RoHS Directive
100 mm 3.937 in
(Note) The sensing range and hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 × 200 mm 7.874 × 7.874 in) as the object.
Opaque, translucent or transparent object
(Note) Make sure to confirm detection with an actual sensor before use.
1 mm 0.039 in or less
15 % or less of operation distance
(Note) The sensing range and hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 × 200 mm 7.874 × 7.874 in) as the object.
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
13 mA or less
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current)
Switchable either Light-ON or Dark-ON
Incorporated
1 ms or less
Orange LED(lights up when the output is ON)
(incorporated on the receiver for thru-beam type)
Green LED(lights up under stable light received condition or stable dark condition)
(incorporated on the receiver for thru-beam type)
-
Continuously variable adjuster(incorporated on the receiver for thru-beam type)
Incorporated(Two units of sensors can be mounted close together.)
IP67 (IEC)
- 25 to +55℃ -13 to +131℃ ℉ (No dew condensation or icing allowed ), Storage: -30 to +70℃ -22 to +158℃ ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each
Infrared LED
860 nm 0.034 mil
Enclosure: PBT (polybutylene terephthalate)
Lens: acrylic
Indicator cover: acrylic
-