Item | Performance characteristics |
---|---|
CE Marking Directive Compliance | ・Low Voltage Directive : EN IEC 60947-5-2 ・EMC Directive : EN IEC 60947-5-2 ・RoHS Directive ・GB/T 14048.10 |
Sensing Range | 700 mm 27.559 in (Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. |
Sensing Object | Opaque, translucent or transparent object (Note) Make sure to confirm detection with an actual sensor before use. |
Hysteresis | 15 % or less of operation distance (Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. |
Repeatability (Perpendicular to Sensing Axis) | 0.3 mm 0.012 in or less |
Supply Voltage | 24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less |
Power Consumption | 2 VA or less |
Output | Relay contact 1 c - Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load) - Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour) - Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour) |
Output: Output Operation | Dark-ON |
Response Time | 10 ms or less |
Operation Indicator | Red LED (lights up when the output is ON) |
Stability Indicator | Green LED (lights up under stable light received condition or stable dark condition) |
Power Indicator | - |
Sensitivity Adjuster | Continuously variable adjuster |
Automatic Interference Prevention Function | Incorporated (Two units of sensors can be mounted close together.) |
Pollution Degree | 3 (Industrial environment) |
Ambient Temperature | –20 to +55 ℃ –4 to +131 ℉ (No dew condensation or icing allowed) (Note), Storage: –30 to +70 ℃ –22 to +158 ℉ (Note):In case the sensor is to be used at an ambient temperature of –15 ℃ +5 ℉, or less, please contact our office. |
Protection | IP66 (IEC) |
Ambient Humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient Illuminance | Incandescent light: 3,500 Lx or less at the light-receiving face |
Voltage Withstandability | 1,500 V AC for one min. between all supply terminals connected together and enclosure, 1,500 V AC for one min. between power supply and output terminals, 1,000 V AC for one min. between relay contact terminals |
Insulation Resistance | 20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals |
Vibration Resistance | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each |
Shock Resistance | 500 m/s2 (50 G approx.) in X, Y and Z directions three times each |
Emitting Element | Infrared LED (modulated) |
Emitting Element: Peak Emission Wavelength | 880 nm 0.035 mil |
Material | Enclosure: Polycarbonate Lens: Polycarbonate Cover: Polycarbonate |
Cable | 0.3 mm2 5-core cabtyre cable, 2 m 6.562 ft long |
Cable Extension | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable |
Weight (Typ.) | 140 g approx. |
Accessory | Adjusting screwdriver: 1 pc. |
Utilization Category | AC-12/DC-12 |
Impulse withstand voltage | 2.5kV |
Output minimum operational current | DC5V 1mA or more |
Turn on time / Turn off time | 10ms / 10ms Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below. |
Maximum response frequency | 50Hz Note:The maximum response frequency is the value calculated below. Maximum response frequency = 1 / (Turn on time+Turn off time) |
Class of protection against electric shock | Out of classification |
Excess gain | 14% Note : Excess gain of NX-D700□ is the value in case sensitivity aduster is in maximum position. |
Note | Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. Note 2 : The output applied voltage should be the same as the supply voltage of the sensor. Note 3 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output.. In addition, use 3A or less fast blow fuse or breaker. |
The service is owned, operated, controlled and managed by Panasonic's distributors.
For pricing, delivery and technical questions related to this service, please direct to them.
Panasonic assumes no responsibility for any dealings you may have with distributors.