| | EMC Directive, RoHS Directive | Gauge pressure | -100.0 to +100.0 kPa | -101.0 to +101.0 kPa -1.030 to +1.030 kgf/cm2 -1.010 to + 1.010 bar -14.65 to +14.65 psi -756 to +756 mmHg | 500 kPa | Air, non-corrosive gas | kPa, kgf/cm2, bar, psi, mmHg | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | 30 mA or less | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 30 V DC or less (between comparative output and +V) - Residual voltage: 2 V or less (at 50 mA source current) | Selectable either NO or NC by key operation | Minimum 2 digits (variable) | ±0.2 % F.S. (within ±4 digits) | 2.5 ms, 25 ms, 250 ms, selectable by key operation | Incorporated | 3 + 1/2 digits, 3-color (white / red / pink) LCD display (Display update period: 250 ms) | -101.0 to +101.0 kPa -1.030 to +1.030 kgf/cm2 -1.010 to + 1.010 bar -14.65 to +14.65 psi -756 to +756 mmHg | IP40 (IEC) | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | 500 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 150 Hz frequency, amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | 2 | I | 2,000 m 6,562 ft or less | +10 to +40℃ +50 to +104 ℉: Within ±1 % F.S. 0 to +50℃ 32 to +122℉: Within ±2.5 % F.S. | Floating | M5 female thread | Enclosure: PBT (glass fiber reinforced) LCD display: Acrylic Pressure port: Brass (nickel plated) Mounting threaded part: Brass O-ring: Nitrile rubber (NBR) Key section: Polycarbonate | 25 g approx. | | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. |
| | EMC Directive, RoHS Directive | Gauge pressure | -100.0 to +100.0 kPa | -101.0 to +101.0 kPa -1.030 to +1.030 kgf/cm2 -1.010 to + 1.010 bar -14.65 to +14.65 psi -756 to +756 mmHg | 500 kPa | Air, non-corrosive gas | kPa, kgf/cm2, bar, psi, mmHg | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | 30 mA or less | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between comparative output and 0 V) - Residual voltage: 2 V or less (at 50 mA sink current) | Selectable either NO or NC by key operation | Minimum 2 digits (variable) | ±0.2 % F.S. (within ±4 digits) | 2.5 ms, 25 ms, 250 ms, selectable by key operation | Incorporated | 3 + 1/2 digits, 3-color (white / red / pink) LCD display (Display update period: 250 ms) | -101.0 to +101.0 kPa -1.030 to +1.030 kgf/cm2 -1.010 to + 1.010 bar -14.65 to +14.65 psi -756 to +756 mmHg | IP40 (IEC) | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | 500 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 150 Hz frequency, amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | 2 | I | 2,000 m 6,562 ft or less | +10 to +40℃ +50 to +104 ℉: Within ±1 % F.S. 0 to +50℃ 32 to +122℉: Within ±2.5 % F.S. | Floating | M5 female thread | Enclosure: PBT (glass fiber reinforced) LCD display: Acrylic Pressure port: Brass (nickel plated) Mounting threaded part: Brass O-ring: Nitrile rubber (NBR) Key section: Polycarbonate | 25 g approx. | CN-14A-C2 (Connector attached cable 2 m 6.562 ft) : 1 pc. | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. |
| | EMC Directive, RoHS Directive | Gauge pressure | 0.000 to +1.000 Mpa | -0.010 to +1.010 MPa -0.1 to +10.30 kgf/cm2 -0.1 to + 10.10 bar -0.1 to +146.5 psi | 1.5 MPa | Air, non-corrosive gas | MPa, kgf/cm2, bar, psi | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | 30 mA or less | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between comparative output and 0 V) - Residual voltage: 2 V or less (at 50 mA sink current) | Selectable either NO or NC by key operation | Minimum 2 digits (variable) | ±0.4 % F.S. (within ±4 digits) | 2.5 ms, 25 ms, 250 ms, selectable by key operation | Incorporated | 3 + 1/2 digits, 3-color (white / red / pink) LCD display (Display update period: 250 ms) | -0.010 to +1.010 MPa -0.1 to +10.30 kgf/cm2 -0.1 to + 10.10 bar -0.1 to +146.5 psi | IP40 (IEC) | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | 500 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 150 Hz frequency, amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | 2 | I | 2,000 m 6,562 ft or less | +10 to +40℃ +50 to +104 ℉: Within ±2 % F.S. 0 to +50℃ 32 to +122℉: Within ±5 % F.S. | Floating | M5 female thread | Enclosure: PBT (glass fiber reinforced) LCD display: Acrylic Pressure port: Brass (nickel plated) Mounting threaded part: Brass O-ring: Nitrile rubber (NBR) Key section: Polycarbonate | 25 g approx. | | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. |
| | EMC Directive, RoHS Directive | Gauge pressure | 0.000 to +1.000 Mpa | -0.010 to +1.010 MPa -0.1 to +10.30 kgf/cm2 -0.1 to + 10.10 bar -0.1 to +146.5 psi | 1.5 MPa | Air, non-corrosive gas | MPa, kgf/cm2, bar, psi | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | 30 mA or less | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 30 V DC or less (between comparative output and +V) - Residual voltage: 2 V or less (at 50 mA source current) | Selectable either NO or NC by key operation | Minimum 2 digits (variable) | ±0.4 % F.S. (within ±4 digits) | 2.5 ms, 25 ms, 250 ms, selectable by key operation | Incorporated | 3 + 1/2 digits, 3-color (white / red / pink) LCD display (Display update period: 250 ms) | -0.010 to +1.010 MPa -0.1 to +10.30 kgf/cm2 -0.1 to + 10.10 bar -0.1 to +146.5 psi | IP40 (IEC) | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | 500 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 150 Hz frequency, amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | 2 | I | 2,000 m 6,562 ft or less | +10 to +40℃ +50 to +104 ℉: Within ±2 % F.S. 0 to +50℃ 32 to +122℉: Within ±5 % F.S. | Floating | M5 female thread | Enclosure: PBT (glass fiber reinforced) LCD display: Acrylic Pressure port: Brass (nickel plated) Mounting threaded part: Brass O-ring: Nitrile rubber (NBR) Key section: Polycarbonate | 25 g approx. | | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. |
| | EMC Directive, RoHS Directive | Gauge pressure | -100.0 to +100.0 kPa | -101.0 to +101.0 kPa -1.030 to +1.030 kgf/cm2 -1.010 to + 1.010 bar -14.65 to +14.65 psi -756 to +756 mmHg | 500 kPa | Air, non-corrosive gas | kPa, kgf/cm2, bar, psi, mmHg | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | 30 mA or less | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 30 V DC or less (between comparative output and +V) - Residual voltage: 2 V or less (at 50 mA source current) | Selectable either NO or NC by key operation | Minimum 2 digits (variable) | ±0.2 % F.S. (within ±4 digits) | 2.5 ms, 25 ms, 250 ms, selectable by key operation | Incorporated | 3 + 1/2 digits, 3-color (white / red / pink) LCD display (Display update period: 250 ms) | -101.0 to +101.0 kPa -1.030 to +1.030 kgf/cm2 -1.010 to + 1.010 bar -14.65 to +14.65 psi -756 to +756 mmHg | IP40 (IEC) | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | 500 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 150 Hz frequency, amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | 2 | I | 2,000 m 6,562 ft or less | +10 to +40℃ +50 to +104 ℉: Within ±1 % F.S. 0 to +50℃ 32 to +122℉: Within ±2.5 % F.S. | Floating | M5 female thread | Enclosure: PBT (glass fiber reinforced) LCD display: Acrylic Pressure port: Brass (nickel plated) Mounting threaded part: Brass O-ring: Nitrile rubber (NBR) Key section: Polycarbonate | 25 g approx. | CN-14A-C2 (Connector attached cable 2 m 6.562 ft) : 1 pc. | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. |
| | EMC Directive, RoHS Directive | Gauge pressure | -100.0 to +100.0 kPa | -101.0 to +101.0 kPa -1.030 to +1.030 kgf/cm2 -1.010 to + 1.010 bar -14.65 to +14.65 psi -756 to +756 mmHg | 500 kPa | Air, non-corrosive gas | kPa, kgf/cm2, bar, psi, mmHg | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | 30 mA or less | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between comparative output and 0 V) - Residual voltage: 2 V or less (at 50 mA sink current) | Selectable either NO or NC by key operation | Minimum 2 digits (variable) | ±0.2 % F.S. (within ±4 digits) | 2.5 ms, 25 ms, 250 ms, selectable by key operation | Incorporated | 3 + 1/2 digits, 3-color (white / red / pink) LCD display (Display update period: 250 ms) | -101.0 to +101.0 kPa -1.030 to +1.030 kgf/cm2 -1.010 to + 1.010 bar -14.65 to +14.65 psi -756 to +756 mmHg | IP40 (IEC) | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | 500 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 150 Hz frequency, amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | 2 | I | 2,000 m 6,562 ft or less | +10 to +40℃ +50 to +104 ℉: Within ±1 % F.S. 0 to +50℃ 32 to +122℉: Within ±2.5 % F.S. | Floating | M5 female thread | Enclosure: PBT (glass fiber reinforced) LCD display: Acrylic Pressure port: Brass (nickel plated) Mounting threaded part: Brass O-ring: Nitrile rubber (NBR) Key section: Polycarbonate | 25 g approx. | | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. |
| | EMC Directive, RoHS Directive | Gauge pressure | 0.000 to +1.000 Mpa | -0.010 to +1.010 MPa -0.1 to +10.30 kgf/cm2 -0.1 to + 10.10 bar -0.1 to +146.5 psi | 1.5 MPa | Air, non-corrosive gas | MPa, kgf/cm2, bar, psi | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | 30 mA or less | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 30 V DC or less (between comparative output and +V) - Residual voltage: 2 V or less (at 50 mA source current) | Selectable either NO or NC by key operation | Minimum 2 digits (variable) | ±0.4 % F.S. (within ±4 digits) | 2.5 ms, 25 ms, 250 ms, selectable by key operation | Incorporated | 3 + 1/2 digits, 3-color (white / red / pink) LCD display (Display update period: 250 ms) | -0.010 to +1.010 MPa -0.1 to +10.30 kgf/cm2 -0.1 to + 10.10 bar -0.1 to +146.5 psi | IP40 (IEC) | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | 500 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 150 Hz frequency, amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | 2 | I | 2,000 m 6,562 ft or less | +10 to +40℃ +50 to +104 ℉: Within ±2 % F.S. 0 to +50℃ 32 to +122℉: Within ±5 % F.S. | Floating | M5 female thread | Enclosure: PBT (glass fiber reinforced) LCD display: Acrylic Pressure port: Brass (nickel plated) Mounting threaded part: Brass O-ring: Nitrile rubber (NBR) Key section: Polycarbonate | 25 g approx. | CN-14A-C2 (Connector attached cable 2 m 6.562 ft) : 1 pc. | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. |
| | EMC Directive, RoHS Directive | Gauge pressure | 0.000 to +1.000 Mpa | -0.010 to +1.010 MPa -0.1 to +10.30 kgf/cm2 -0.1 to + 10.10 bar -0.1 to +146.5 psi | 1.5 MPa | Air, non-corrosive gas | MPa, kgf/cm2, bar, psi | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | 30 mA or less | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between comparative output and 0 V) - Residual voltage: 2 V or less (at 50 mA sink current) | Selectable either NO or NC by key operation | Minimum 2 digits (variable) | ±0.4 % F.S. (within ±4 digits) | 2.5 ms, 25 ms, 250 ms, selectable by key operation | Incorporated | 3 + 1/2 digits, 3-color (white / red / pink) LCD display (Display update period: 250 ms) | -0.010 to +1.010 MPa -0.1 to +10.30 kgf/cm2 -0.1 to + 10.10 bar -0.1 to +146.5 psi | IP40 (IEC) | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | 500 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 150 Hz frequency, amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | 2 | I | 2,000 m 6,562 ft or less | +10 to +40℃ +50 to +104 ℉: Within ±2 % F.S. 0 to +50℃ 32 to +122℉: Within ±5 % F.S. | Floating | M5 female thread | Enclosure: PBT (glass fiber reinforced) LCD display: Acrylic Pressure port: Brass (nickel plated) Mounting threaded part: Brass O-ring: Nitrile rubber (NBR) Key section: Polycarbonate | 25 g approx. | CN-14A-C2 (Connector attached cable 2 m 6.562 ft) : 1 pc. | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. |