| | EMC Directive, RoHS Directive | Differential pressure | 0 to 2.00 kPa.D {0 to 204 mmH2O.D} | 0 to 2.00 kPa.D {0 to 204 mmH2O.D} | 0.01 kPa.D {1 mmH2O.D} | 6 kPa.D {612 mmH2O.D} | Non-corrosive gas | kPa, mmH2O | 12 to 24 V DC +10/-15% Ripple P-P 10 % or less | 75 mA or less | NPN open-collector transistor ・Maximum sink current : 100 mA ・Applied voltage : 30 V DC or less (between comparative output and 0 V) ・Residual voltage : 1 V or less (at 100 mA sink current) 0.4 V or less (at 16 mA sink current) | DC-12 or DC-13 | Selectable either normally open (NO) or normally closed (NC) by the key | 0.01 kPa.D {1 mmH2O.D} | Within ±1 % F.S. | 10 ms or less | Incorporated | Output current : 4 to 20 mA (from 0 to 1.96 kPa.D {0 to 200 mmH2O.D}) Zero-point : within 4 mA ± 1 % F.S. Span : within 16 mA ± 3 % F.S. Linearity : within ±1 % F.S. Load resistance : 0 to 250 Ω | 3 digit red LED display (Sampling rate : 4 times/sec. approx.) | -0.05 to 2.10 kPa.D {-5 to 210 mmH2O.D} | Orange LED (lights up when the comparative output is ON) | Red LED (The indicator corresponding to the selected unit lights up during the sensing mode.) | Red LED (blinks in the M1 setting mode) | Red LED (blinks in the M2 setting mode) | 3 (Industrial environment) | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉ | 35 to 85 % RH, Storage : 35 to 85 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | Over ambient temperature range 0 to +50 ℃ +32 to +122 ℉ : within ±3 % F.S. of detected pressure at +25 ℃ +77 ℉ | ø4.6 mm ø0.181 in resin pipe (Note): For production before April 2015 : ø4.8 mm ø0.189 in | Front case : ABS, Rear case : ABS, LED display : Acrylic, Pressure port : PA | 0.18 mm2 4-core oil resistant cabtyre cable, 2 m 6.562 ft long | Extension up to total 100 m 328.084 ft (less than 10 m 32.808 ft when conforming to CE marking) is possible with 0.3 mm2, or more, cable. | Net weight : 75 g approx., Gross weight : 135 g approx | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. |
| | EMC Directive, RoHS Directive | Differential pressure | 0 to 2.00 kPa.D {0 to 204 mmH2O.D} | 0 to 2.00 kPa.D {0 to 204 mmH2O.D} | 0.01 kPa.D {1 mmH2O.D} | 6 kPa.D {612 mmH2O.D} | Non-corrosive gas | kPa, mmH2O | 12 to 24 V DC +10/-15% Ripple P-P 10 % or less | 50 mA or less | NPN open-collector transistor ・Maximum sink current : 100 mA ・Applied voltage : 30 V DC or less (between comparative output and 0 V) ・Residual voltage : 1 V or less (at 100 mA sink current) 0.4 V or less (at 16 mA sink current) | DC-12 or DC-13 | Selectable either normally open (NO) or normally closed (NC) by the key | 0.01 kPa.D {1 mmH2O.D} | Within ±1 % F.S. | 10 ms or less | Incorporated | - | 3 digit red LED display (Sampling rate : 4 times/sec. approx.) | -0.05 to 2.10 kPa.D {-5 to 210 mmH2O.D} | Orange LED (lights up when the comparative output is ON) | Red LED (The indicator corresponding to the selected unit lights up during the sensing mode.) | Red LED (blinks in the M1 setting mode) | Red LED (blinks in the M2 setting mode) | 3 (Industrial environment) | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉ | 35 to 85 % RH, Storage : 35 to 85 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | Over ambient temperature range 0 to +50 ℃ +32 to +122 ℉ : within ±3 % F.S. of detected pressure at +25 ℃ +77 ℉ | ø4.6 mm ø0.181 in resin pipe (Note): For production before April 2015 : ø4.8 mm ø0.189 in | Front case : ABS, Rear case : ABS, LED display : Acrylic, Pressure port : PA | 0.18 mm2 3-core oil resistant cabtyre cable, 2 m 6.562 ft long | Extension up to total 100 m 328.084 ft (less than 10 m 32.808 ft when conforming to CE marking) is possible with 0.3 mm2, or more, cable. | Net weight : 75 g approx., Gross weight : 135 g approx | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. |