Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in, Iron(SPCC): -, Aluminum: -, Copper: -, Brass: -, Stainless steel (SUS304): - (Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.
Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in, Iron(SPCC): 0.07 to 10 mm 0.003 to 0.394 in, Aluminum: 0.03 to 10 mm 0.001 to 0.394 in, Copper: 0.03 to 10 mm 0.001 to 0.394 in, Brass: 0.03 to 10 mm 0.001 to 0.394 in, Stainless steel (SUS304): 0.1 to 10 mm 0.004 to 0.394 in (Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.
Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in, Iron(SPCC): 0.07 to 6 mm 0.003 to 0.236 in, Aluminum: 0.03 to 6 mm 0.001 to 0.236 in, Copper: 0.03 to 6 mm 0.001 to 0.236 in, Brass: 0.03 to 6 mm 0.001 to 0.236 in, Stainless steel (SUS304): 0.1 to 6 mm 0.004 to 0.236 in (Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.
Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in, Iron(SPCC): -, Aluminum: -, Copper: -, Brass: -, Stainless steel (SUS304): - (Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.
IP67 (IEC), IP67G
-10 to +60 degrees +14 to +140 degrees Fahrenheit , Storage: -25 to +70 degrees -13 to +158 degrees Fahrenheit
45 to 85 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Sensing face: Polyacetal Main body: Stainless steel
Sender: 0.5 2 single core shielded cable, 20 m 65.617 ft long Receiver: 0.3 2 2-core shielded cable, 20 m 65.617 ft long
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
12 V DC: 700 mA or less, 24 V DC: 400 mA or less
NPN open-collector transistor -Maximum sink current: 100 mA -Applied voltage: 30 V DC or less (between output and 0 V) -Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
OFF above the one-sheet threshold level
OFF above the two-sheet threshold level
OFF when an error occurs
Incorporated
Automatically selected either 5 ms or less, or 30 ms or less, depending on the object
Set values of eight channels stored
Incorporated
Incorporated
Green LED (lights up when the power is ON)
Red LED (lights up during SET mode and when an error occurs during RUN mode)
Green LED (lights up when OUT-1 is OFF, and blinks twice on completion of 0-ADJ. or SET-1 setting in SET mode)
2-color indicator (lights up green during normal sensing mode, but yellow during precise sensing mode)
Red LED (lights up when OUT-2 is OFF, and blinks twice on completion of 0-ADJ. or SET-2 setting in SET mode)
Yellow LED x 1 and green LED x 6 (indicate the sensing level)
Approx. 50 ms fixed delay timer (switchable either effective or ineffective)
-10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 C° -13 to +158 ℉
45 to 85 % RH, Storage: 35 to 90 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in
Iron(SPCC): -
Aluminum: -
Copper: -
Brass: -
Stainless steel (SUS304): -
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above.
Please contact our office for details.
Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in
Iron(SPCC): 0.07 to 10 mm 0.003 to 0.394 in
Aluminum: 0.03 to 10 mm 0.001 to 0.394 in
Copper: 0.03 to 10 mm 0.001 to 0.394 in
Brass: 0.03 to 10 mm 0.001 to 0.394 in
Stainless steel (SUS304): 0.1 to 10 mm 0.004 to 0.394 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above.
Please contact our office for details.
Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in
Iron(SPCC): 0.07 to 6 mm 0.003 to 0.236 in
Aluminum: 0.03 to 6 mm 0.001 to 0.236 in
Copper: 0.03 to 6 mm 0.001 to 0.236 in
Brass: 0.03 to 6 mm 0.001 to 0.236 in
Stainless steel (SUS304): 0.1 to 6 mm 0.004 to 0.236 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above.
Please contact our office for details.
Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in
Iron(SPCC): -
Aluminum: -
Copper: -
Brass: -
Stainless steel (SUS304): -
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above.
Please contact our office for details.
IP67 (IEC), IP67G
-10 to +60 degrees +14 to +140 degrees Fahrenheit , Storage: -25 to +70 degrees -13 to +158 degrees Fahrenheit
45 to 85 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Sensing face: Polyacetal Main body: Stainless steel
Sender: 0.5 2 single core shielded cable, 3 m 9.843 ft long Receiver: 0.3 2 2-core shielded cable, 3 m 9.843 ft long
Extension up to total 20 m 65.617 ft is possible with an equivalent shielded cable.
Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in, Iron(SPCC): -, Aluminum: -, Copper: -, Brass: -, Stainless steel (SUS304): - (Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.
Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in, Iron(SPCC): 0.07 to 10 mm 0.003 to 0.394 in, Aluminum: 0.03 to 10 mm 0.001 to 0.394 in, Copper: 0.03 to 10 mm 0.001 to 0.394 in, Brass: 0.03 to 10 mm 0.001 to 0.394 in, Stainless steel (SUS304): 0.1 to 10 mm 0.004 to 0.394 in (Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.
Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in, Iron(SPCC): 0.07 to 6 mm 0.003 to 0.236 in, Aluminum: 0.03 to 6 mm 0.001 to 0.236 in, Copper: 0.03 to 6 mm 0.001 to 0.236 in, Brass: 0.03 to 6 mm 0.001 to 0.236 in, Stainless steel (SUS304): 0.1 to 6 mm 0.004 to 0.236 in (Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.
Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in, Iron(SPCC): -, Aluminum: -, Copper: -, Brass: -, Stainless steel (SUS304): - (Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.
IP67 (IEC), IP67G
-10 to +60 degrees +14 to +140 degrees Fahrenheit , Storage: -25 to +70 degrees -13 to +158 degrees Fahrenheit
45 to 85 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Sensing face: Polyacetal Main body: Stainless steel
Sender: 0.5 2 single core shielded cable, 10 m 32.808 ft long Receiver: 0.3 2 2-core shielded cable, 10 m 32.808 ft long
Extension up to total 20 m 65.617 ft is possible with an equivalent shielded cable.
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
12 V DC: 700 mA or less, 24 V DC: 400 mA or less
NPN open-collector transistor -Maximum sink current: 100 mA -Applied voltage: 30 V DC or less (between output and 0 V) -Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
OFF above the one-sheet threshold level
OFF above the two-sheet threshold level
OFF when an error occurs
Incorporated
5 ms or less
Set values of eight channels stored
Incorporated
Incorporated
Green LED (lights up when the power is ON)
Red LED (lights up during SET mode and when an error occurs during RUN mode)
Green LED (lights up when OUT-1 is OFF, and blinks twice on completion of 0-ADJ. or SET-1 setting in SET mode)
2-color indicator (lights up green during normal sensing mode, but yellow during precise sensing mode)
Red LED (lights up when OUT-2 is OFF, and blinks twice on completion of 0-ADJ. or SET-2 setting in SET mode)
Yellow LED x 1 and green LED x 6 (indicate the sensing level)
Approx. 50 ms fixed delay timer (switchable either effective or ineffective)
-10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 C° -13 to +158 ℉
45 to 85 % RH, Storage: 35 to 90 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
12 V DC: 700 mA or less, 24 V DC: 400 mA or less
NPN open-collector transistor -Maximum sink current: 100 mA -Applied voltage: 30 V DC or less (between output and 0 V) -Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
OFF above the one-sheet threshold level
OFF above the two-sheet threshold level
OFF when an error occurs
Incorporated
Automatically selected either 5 ms or less, or 30 ms or less, depending on the object
Set values of eight channels stored
Incorporated
Incorporated
Green LED (lights up when the power is ON)
Red LED (lights up during SET mode and when an error occurs during RUN mode)
Green LED (lights up when OUT-1 is OFF, and blinks twice on completion of 0-ADJ. or SET-1 setting in SET mode)
2-color indicator (lights up green during normal sensing mode, but yellow during precise sensing mode)
Red LED (lights up when OUT-2 is OFF, and blinks twice on completion of 0-ADJ. or SET-2 setting in SET mode)
Yellow LED x 1 and green LED x 6 (indicate the sensing level)
Approx. 50 ms fixed delay timer (switchable either effective or ineffective)
-10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 C° -13 to +158 ℉
45 to 85 % RH, Storage: 35 to 90 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Standard sensing object size: 80 x 80 mm 3.150 x 3.150 in
Iron(SPCC): 0.07 to 1 mm 0.003 to 0.039 in
Aluminum: 0.03 to 6 mm 0.001 to 0.236 in
Copper: 0.03 to 6 mm 0.001 to 0.236 in
Brass: 0.03 to 6 mm 0.001 to 0.236 in
Stainless steel (SUS304): 0.1 to 6 mm 0.004 to 0.236 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above.
Please contact our office for details.
Standard sensing object size: 80 x 80 mm 3.150 x 3.150 in
Iron(SPCC): 0.01 to 0.3 mm 0.0004 to 0.012 in
Aluminum: 0.015 to 1 mm 0.001 to 0.039 in
Copper: 0.018 to 1 mm 0.001 to 0.039 in
Brass: 0.01 to 1 mm 0.0004 to 0.039 in
Stainless steel (SUS304): 0.05 to 2 mm 0.002 to 0.079 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above.
Please contact our office for details.
Standard sensing object size: 80 x 80 mm 3.150 x 3.150 in
Iron(SPCC): 0.07 to 0.5 mm 0.003 to 0.020 in
Aluminum: 0.03 to 2 mm 0.001 to 0.079 in
Copper: 0.03 to 2 mm 0.001 to 0.079 in
Brass: 0.03 to 2 mm 0.001 to 0.079 in
Stainless steel (SUS304): 0.1 to 2 mm 0.004 to 0.079 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above.
Please contact our office for details.
Standard sensing object size: 80 x 80 mm 3.150 x 3.150 in
Iron(SPCC): 0.01 to 0.1 mm 0.0004 to 0.004 in
Aluminum: 0.015 to 1 mm 0.001 to 0.039 in
Copper: 0.018 to 1 mm 0.001 to 0.039 in
Brass: 0.01 to 1 mm 0.0004 to 0.039 in
Stainless steel (SUS304): 0.05 to 1 mm 0.002 to 0.039 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above.
Please contact our office for details.
IP67 (IEC)
-10 to +60 degrees +14 to +140 degrees Fahrenheit , Storage: -25 to +70 degrees -13 to +158 degrees Fahrenheit
45 to 85 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Enclosure: Polyalylate
Sender: 0.3 2 single core shielded cable, 3 m 9.843 ft long Receiver: 0.1 2 2-core shielded cable, 3 m 9.843 ft long
Extension up to total 20 m 65.617 ft is possible with an equivalent shielded cable.
Net weight: 80 g approx.
Sensor head mounting bracket: 1 set for sender and receiver
Standard sensing object size: 20 x 20 mm 0.787 x 0.787 in
Iron(SPCC): -
Aluminum: -
Copper: -
Brass: -
Stainless steel (SUS304): -
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above.
Please contact our office for details.
Standard sensing object size: 20 x 20 mm 0.787 x 0.787 in
Iron(SPCC): 0.01 to 0.1 mm 0.0004 to 0.004 in
Aluminum: 0.015 to 1 mm 0.001 to 0.039 in
Copper: 0.018 to 1 mm 0.001 to 0.039 in
Brass: 0.03 to 1 mm 0.001 to 0.039 in
Stainless steel (SUS304): 0.3 to 1 mm 0.012 to 0.039 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above.
Please contact our office for details.
Standard sensing object size: 20 x 20 mm 0.787 x 0.787 in
Iron(SPCC): -
Aluminum: -
Copper: -
Brass: -
Stainless steel (SUS304): -
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above.
Please contact our office for details.
Standard sensing object size: 20 x 20 mm 0.787 x 0.787 in
Iron(SPCC): 0.03 to 0.1 mm 0.001 to 0.004 in
Aluminum: 0.015 to 1 mm 0.001 to 0.039 in
Copper: 0.018 to 0.3 mm 0.001 to 0.012 in
Brass: 0.03 to 0.5 mm 0.001 to 0.020 in
Stainless steel (SUS304): 0.3 to 1 mm 0.012 to 0.039 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above.
Please contact our office for details.
IP67 (IEC)
-10 to +60 degrees +14 to +140 degrees Fahrenheit , Storage: -25 to +70 degrees -13 to +158 degrees Fahrenheit
45 to 85 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in, Iron(SPCC): -, Aluminum: -, Copper: -, Brass: -, Stainless steel (SUS304): - (Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.
Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in, Iron(SPCC): 0.07 to 10 mm 0.003 to 0.394 in, Aluminum: 0.03 to 10 mm 0.001 to 0.394 in, Copper: 0.03 to 10 mm 0.001 to 0.394 in, Brass: 0.03 to 10 mm 0.001 to 0.394 in, Stainless steel (SUS304): 0.1 to 10 mm 0.004 to 0.394 in (Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.
Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in, Iron(SPCC): 0.07 to 6 mm 0.003 to 0.236 in, Aluminum: 0.03 to 6 mm 0.001 to 0.236 in, Copper: 0.03 to 6 mm 0.001 to 0.236 in, Brass: 0.03 to 6 mm 0.001 to 0.236 in, Stainless steel (SUS304): 0.1 to 6 mm 0.004 to 0.236 in (Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.
Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in, Iron(SPCC): -, Aluminum: -, Copper: -, Brass: -, Stainless steel (SUS304): - (Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.
IP67 (IEC), IP67G
-10 to +60 degrees +14 to +140 degrees Fahrenheit , Storage: -25 to +70 degrees -13 to +158 degrees Fahrenheit
45 to 85 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Sensing face: Polyacetal Main body: Stainless steel
Sender: 0.5 2 single core shielded cable, 20 m 65.617 ft long Receiver: 0.3 2 2-core shielded cable, 20 m 65.617 ft long
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
12 V DC: 700 mA or less, 24 V DC: 400 mA or less
NPN open-collector transistor -Maximum sink current: 100 mA -Applied voltage: 30 V DC or less (between output and 0 V) -Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
OFF above the one-sheet threshold level
OFF above the two-sheet threshold level
OFF when an error occurs
Incorporated
Automatically selected either 5 ms or less, or 30 ms or less, depending on the object
Set values of eight channels stored
Incorporated
Incorporated
Green LED (lights up when the power is ON)
Red LED (lights up during SET mode and when an error occurs during RUN mode)
Green LED (lights up when OUT-1 is OFF, and blinks twice on completion of 0-ADJ. or SET-1 setting in SET mode)
2-color indicator (lights up green during normal sensing mode, but yellow during precise sensing mode)
Red LED (lights up when OUT-2 is OFF, and blinks twice on completion of 0-ADJ. or SET-2 setting in SET mode)
Yellow LED x 1 and green LED x 6 (indicate the sensing level)
Approx. 50 ms fixed delay timer (switchable either effective or ineffective)
-10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 C° -13 to +158 ℉
45 to 85 % RH, Storage: 35 to 90 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in
Iron(SPCC): -
Aluminum: -
Copper: -
Brass: -
Stainless steel (SUS304): -
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above.
Please contact our office for details.
Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in
Iron(SPCC): 0.07 to 10 mm 0.003 to 0.394 in
Aluminum: 0.03 to 10 mm 0.001 to 0.394 in
Copper: 0.03 to 10 mm 0.001 to 0.394 in
Brass: 0.03 to 10 mm 0.001 to 0.394 in
Stainless steel (SUS304): 0.1 to 10 mm 0.004 to 0.394 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above.
Please contact our office for details.
Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in
Iron(SPCC): 0.07 to 6 mm 0.003 to 0.236 in
Aluminum: 0.03 to 6 mm 0.001 to 0.236 in
Copper: 0.03 to 6 mm 0.001 to 0.236 in
Brass: 0.03 to 6 mm 0.001 to 0.236 in
Stainless steel (SUS304): 0.1 to 6 mm 0.004 to 0.236 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above.
Please contact our office for details.
Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in
Iron(SPCC): -
Aluminum: -
Copper: -
Brass: -
Stainless steel (SUS304): -
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above.
Please contact our office for details.
IP67 (IEC), IP67G
-10 to +60 degrees +14 to +140 degrees Fahrenheit , Storage: -25 to +70 degrees -13 to +158 degrees Fahrenheit
45 to 85 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Sensing face: Polyacetal Main body: Stainless steel
Sender: 0.5 2 single core shielded cable, 3 m 9.843 ft long Receiver: 0.3 2 2-core shielded cable, 3 m 9.843 ft long
Extension up to total 20 m 65.617 ft is possible with an equivalent shielded cable.
Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in, Iron(SPCC): -, Aluminum: -, Copper: -, Brass: -, Stainless steel (SUS304): - (Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.
Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in, Iron(SPCC): 0.07 to 10 mm 0.003 to 0.394 in, Aluminum: 0.03 to 10 mm 0.001 to 0.394 in, Copper: 0.03 to 10 mm 0.001 to 0.394 in, Brass: 0.03 to 10 mm 0.001 to 0.394 in, Stainless steel (SUS304): 0.1 to 10 mm 0.004 to 0.394 in (Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.
Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in, Iron(SPCC): 0.07 to 6 mm 0.003 to 0.236 in, Aluminum: 0.03 to 6 mm 0.001 to 0.236 in, Copper: 0.03 to 6 mm 0.001 to 0.236 in, Brass: 0.03 to 6 mm 0.001 to 0.236 in, Stainless steel (SUS304): 0.1 to 6 mm 0.004 to 0.236 in (Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.
Standard sensing object size: 200 x 200 mm 7.874 x 7.874 in, Iron(SPCC): -, Aluminum: -, Copper: -, Brass: -, Stainless steel (SUS304): - (Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.
IP67 (IEC), IP67G
-10 to +60 degrees +14 to +140 degrees Fahrenheit , Storage: -25 to +70 degrees -13 to +158 degrees Fahrenheit
45 to 85 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Sensing face: Polyacetal Main body: Stainless steel
Sender: 0.5 2 single core shielded cable, 10 m 32.808 ft long Receiver: 0.3 2 2-core shielded cable, 10 m 32.808 ft long
Extension up to total 20 m 65.617 ft is possible with an equivalent shielded cable.
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
12 V DC: 700 mA or less, 24 V DC: 400 mA or less
NPN open-collector transistor -Maximum sink current: 100 mA -Applied voltage: 30 V DC or less (between output and 0 V) -Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
OFF above the one-sheet threshold level
OFF above the two-sheet threshold level
OFF when an error occurs
Incorporated
5 ms or less
Set values of eight channels stored
Incorporated
Incorporated
Green LED (lights up when the power is ON)
Red LED (lights up during SET mode and when an error occurs during RUN mode)
Green LED (lights up when OUT-1 is OFF, and blinks twice on completion of 0-ADJ. or SET-1 setting in SET mode)
2-color indicator (lights up green during normal sensing mode, but yellow during precise sensing mode)
Red LED (lights up when OUT-2 is OFF, and blinks twice on completion of 0-ADJ. or SET-2 setting in SET mode)
Yellow LED x 1 and green LED x 6 (indicate the sensing level)
Approx. 50 ms fixed delay timer (switchable either effective or ineffective)
-10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 C° -13 to +158 ℉
45 to 85 % RH, Storage: 35 to 90 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
12 V DC: 700 mA or less, 24 V DC: 400 mA or less
NPN open-collector transistor -Maximum sink current: 100 mA -Applied voltage: 30 V DC or less (between output and 0 V) -Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
OFF above the one-sheet threshold level
OFF above the two-sheet threshold level
OFF when an error occurs
Incorporated
Automatically selected either 5 ms or less, or 30 ms or less, depending on the object
Set values of eight channels stored
Incorporated
Incorporated
Green LED (lights up when the power is ON)
Red LED (lights up during SET mode and when an error occurs during RUN mode)
Green LED (lights up when OUT-1 is OFF, and blinks twice on completion of 0-ADJ. or SET-1 setting in SET mode)
2-color indicator (lights up green during normal sensing mode, but yellow during precise sensing mode)
Red LED (lights up when OUT-2 is OFF, and blinks twice on completion of 0-ADJ. or SET-2 setting in SET mode)
Yellow LED x 1 and green LED x 6 (indicate the sensing level)
Approx. 50 ms fixed delay timer (switchable either effective or ineffective)
-10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 C° -13 to +158 ℉
45 to 85 % RH, Storage: 35 to 90 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Standard sensing object size: 80 x 80 mm 3.150 x 3.150 in
Iron(SPCC): 0.07 to 1 mm 0.003 to 0.039 in
Aluminum: 0.03 to 6 mm 0.001 to 0.236 in
Copper: 0.03 to 6 mm 0.001 to 0.236 in
Brass: 0.03 to 6 mm 0.001 to 0.236 in
Stainless steel (SUS304): 0.1 to 6 mm 0.004 to 0.236 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above.
Please contact our office for details.
Standard sensing object size: 80 x 80 mm 3.150 x 3.150 in
Iron(SPCC): 0.01 to 0.3 mm 0.0004 to 0.012 in
Aluminum: 0.015 to 1 mm 0.001 to 0.039 in
Copper: 0.018 to 1 mm 0.001 to 0.039 in
Brass: 0.01 to 1 mm 0.0004 to 0.039 in
Stainless steel (SUS304): 0.05 to 2 mm 0.002 to 0.079 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above.
Please contact our office for details.
Standard sensing object size: 80 x 80 mm 3.150 x 3.150 in
Iron(SPCC): 0.07 to 0.5 mm 0.003 to 0.020 in
Aluminum: 0.03 to 2 mm 0.001 to 0.079 in
Copper: 0.03 to 2 mm 0.001 to 0.079 in
Brass: 0.03 to 2 mm 0.001 to 0.079 in
Stainless steel (SUS304): 0.1 to 2 mm 0.004 to 0.079 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above.
Please contact our office for details.
Standard sensing object size: 80 x 80 mm 3.150 x 3.150 in
Iron(SPCC): 0.01 to 0.1 mm 0.0004 to 0.004 in
Aluminum: 0.015 to 1 mm 0.001 to 0.039 in
Copper: 0.018 to 1 mm 0.001 to 0.039 in
Brass: 0.01 to 1 mm 0.0004 to 0.039 in
Stainless steel (SUS304): 0.05 to 1 mm 0.002 to 0.039 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above.
Please contact our office for details.
IP67 (IEC)
-10 to +60 degrees +14 to +140 degrees Fahrenheit , Storage: -25 to +70 degrees -13 to +158 degrees Fahrenheit
45 to 85 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Enclosure: Polyalylate
Sender: 0.3 2 single core shielded cable, 3 m 9.843 ft long Receiver: 0.1 2 2-core shielded cable, 3 m 9.843 ft long
Extension up to total 20 m 65.617 ft is possible with an equivalent shielded cable.
Net weight: 80 g approx.
Sensor head mounting bracket: 1 set for sender and receiver
Standard sensing object size: 20 x 20 mm 0.787 x 0.787 in
Iron(SPCC): -
Aluminum: -
Copper: -
Brass: -
Stainless steel (SUS304): -
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above.
Please contact our office for details.
Standard sensing object size: 20 x 20 mm 0.787 x 0.787 in
Iron(SPCC): 0.01 to 0.1 mm 0.0004 to 0.004 in
Aluminum: 0.015 to 1 mm 0.001 to 0.039 in
Copper: 0.018 to 1 mm 0.001 to 0.039 in
Brass: 0.03 to 1 mm 0.001 to 0.039 in
Stainless steel (SUS304): 0.3 to 1 mm 0.012 to 0.039 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above.
Please contact our office for details.
Standard sensing object size: 20 x 20 mm 0.787 x 0.787 in
Iron(SPCC): -
Aluminum: -
Copper: -
Brass: -
Stainless steel (SUS304): -
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above.
Please contact our office for details.
Standard sensing object size: 20 x 20 mm 0.787 x 0.787 in
Iron(SPCC): 0.03 to 0.1 mm 0.001 to 0.004 in
Aluminum: 0.015 to 1 mm 0.001 to 0.039 in
Copper: 0.018 to 0.3 mm 0.001 to 0.012 in
Brass: 0.03 to 0.5 mm 0.001 to 0.020 in
Stainless steel (SUS304): 0.3 to 1 mm 0.012 to 0.039 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above.
Please contact our office for details.
IP67 (IEC)
-10 to +60 degrees +14 to +140 degrees Fahrenheit , Storage: -25 to +70 degrees -13 to +158 degrees Fahrenheit
45 to 85 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Sender: 0.3 2 single core shielded cable, 3 m 9.843 ft long Receiver: 0.1 2 2-core shielded cable, 3 m 9.843 ft long
Extension up to total 20 m 65.617 ft is possible with an equivalent shielded cable.
Net weight: 90 g approx.
-
You May Also Be Interested In Time of Flight (ToF) Camera Sensors
Instantly Detect Distance With Time of Flight (ToF) Camera Sensors
Panasonic Time of Flight (ToF) Cameras are compact, real-time, sensing cameras based on the ToF principle. Available in indoor and outdoor models, these cameras instantly detect distance between the camera and the targeted object with depth, infrared, and color (RGB) images. The GC1 indoor model produces RGB (640x480), depth map (320x240) (640x480) images. As well, engineers no longer need separate cameras for the depth, IR, and color images with 14/16/36 bit data formats. The HC4W outdoor model has a wide 90° FOV and is used in various applications such as security, autonomous vehicles and robotics.