Communication Unit for Digital Displacement Sensors SC-HG1
Direct Transfer Of High-Precision Measurement Values: New Communication Unit For The HG-S Sensor Series
The new RS485 Communication Unit for the HG-S Sensor Series is used to transfer high-precision measurement values directly, making data traceability easier than before. Communication does not only work for measurement values, but also for parameters, making it easy to manage inspection results and identify causes in the event of a failure.
Communication Unit for Digital Displacement Sensors SC-HG1
Part number list
Results 3
Models table for series Communication Unit for Digital Displacement Sensors SC-HG1
Part No.
Datasheet
CE Marking Directive Compliance
Compatible Controllers
Number of Connectable Units
Supply Voltage
Current Consumption
Communication Method
Synchronization Method
Communication Protocol
Communication Speed
Electrical Characteristics
Number of Connectable Units: Host (RS-485)
Number of Connectable Units: Sensors
Stop Bit Length
Parity Check
Data Bit Length
Remote Station Type
Number of Occupied Station
Station No. Setting
Baud Rate / Maximum Overall Cable Distance
Degree of Pollution
Operating Altitude
Environmental Resistance: Protection
Environmental Resistance: Ambient Temperature
Environmental Resistance: Ambient Humidity
Voltage Withstandability
Insulation Resistance
Environmental Resistance: Vibration Resistance
Environmental Resistance: Shock Resistance
Material
Total Extension Distance
Communication Cable
Weight (Typ.)
Remark
Network No. Setting
Cyclic transmission (Maximum number of links per station)
Transient Transmission
Transmission line type
Maximum Transmission Distance
Max. Overall Cable & Transmission Distance
Cascade Connection Levels
Maximum Number of Connectable Controllers
Cyclic Transmission (Maximum Number Of Links Per Station)
Environmental Resistance: Voltage Withstandability
Maximum of 15 controllers (one master, 14 slaves) per SC‑HG1‑CEF unit
24V DC ±10%, including 0.5V ripple (P-P) (Note) : Power is supplied from a connected controller / master controller.
200 mA or less
CC-Link IE Field
1 Gbps
Remote device station
1 to 120 (decimal) (0 and 121 or more: Error)
2
2,000 m 6561.68 ft or less (Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
IP40 (IEC)
10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed) Storage: -20 to +60 ℃ -4 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58Hz), maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Enclosure: Polycarbonate
Ethernet cable that satisfies 1000BASE-T standard Category 5e or higher (Double-shielded / STP, straight cable) (Note) : Use CC-Link Partner Association recommended cable.
Net weight: 100 g approx., Gross weight: 150 g approx.
Where measurement conditions have not been specified precisely, the conditions used were ambient temperature +20 ℃ +68 ℉.
1 to 239 (decimal) [1 to EF (hex)] (0 and 240 or more: Error) (Note) : For the network number setting on this product, convert the network number to hex and set the hex value.
RX/RY:128 points each (128 bits), 16 bytes, RWr/RWw: 64 points each (64 words), 128 bytes
Server function only, data size 1024 bytes
Line, star, (mixing of line and star types is possible), ring
100 m 328.084 ft
121 units (1 master station, 120 slave stations)
Maximum 20
Maximum of 15 units (one master, 14 slaves) per SC‑HG1‑CEF unit
RX/RY:128 points each (128 bits), 16 bytes,
RWr/RWw: 64 points each (64 words), 128 bytes
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ or more, with 250 V DC megger between all supply
terminals connected together and enclosure
HG-SC□
Line, star, (mixing of line and star types is possible), ring
2
Net weight: 100 g approx., Gross weight: 150 g approx.
1 to 99 units when MODBUS (RTU/ASCII) is used, 1 to 64 units when MEWTOCOL-COM is used
Maximum of 15 controllers (one master, 14 slaves) per SC-HG1-485 unit
1 bit / 2 bits
Even / Odd / None
8 bits (RTU) / 7 bits (ASCII)
2
2,000 m 6561.68 ft or less (Note): Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
IP40 (IEC)
-10 to +45 ℃ 14 to +113 ℉ (No condensation or icing), Storage : -20 to +60 ℃ -4 to +140 ℉
35 to 85 % RH, Storage : 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58Hz), maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Unit case : Polycarbonate
Communication cable : 1,200 m 3,937.008 ft or less between SC-HG1-485 (terminal) and PLC
Net weight : 75 g approx., Gross weight : 120 g approx.
Where measurement conditions have not been specified precisely, the conditions used were ambient temperature +20 ℃ +68 ℉.
EMC Directive (Note), RoHS Directive (Note): If our product will be incorporated in a customer product that will comply with the EMC Directive, install our product in a conductive box in accordance with "PLC User's Manual [Published by Mitsubishi Electric Corporation]".
HG-SC□ / HG-TC□
Maximum of 15 controllers (one master, 14 slaves) per SC-HG1-C unit
24 V DC ±10 %, including ripple 0.5 V (P-P) (Note): Power is supplied from a connected controller / master controller.
・10 Mbps/100 m 328.084 ft ・5 Mbps/160 m 524.934 ft ・2.5 Mbps/400 m 1,312.336 ft ・625 kbps/900 m 2,952.756 ft ・156 kbps/1,200 m 3,937.008 ft
2
2,000 m 6561.68 ft or less (Note): Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
IP40 (IEC)
-10 to +45 ℃ +14 to +113 ℉ (No condensation or icing), Storage : -20 to +60 ℃ -4 to +140 ℉
35 to 85 % RH, Storage : 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58Hz), maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Unit case : Polycarbonate
Specified cable (shielded twisted cable) (Note): Use only a special-use communication cable that is approved by the CC-Link Partner Association.
Net weight : 80 g approx., Gross weight : 130 g approx.
Where measurement conditions have not been specified precisely, the conditions used were ambient temperature +20 ℃ +68 ℉.
Models table for series Communication Unit for Digital Displacement Sensors SC-HG1
Part No.
Datasheet
CE Marking Directive Compliance
Compatible Controllers
Number of Connectable Units
Supply Voltage
Current Consumption
Communication Method
Synchronization Method
Communication Protocol
Communication Speed
Electrical Characteristics
Number of Connectable Units: Host (RS-485)
Number of Connectable Units: Sensors
Stop Bit Length
Parity Check
Data Bit Length
Remote Station Type
Number of Occupied Station
Station No. Setting
Baud Rate / Maximum Overall Cable Distance
Degree of Pollution
Operating Altitude
Environmental Resistance: Protection
Environmental Resistance: Ambient Temperature
Environmental Resistance: Ambient Humidity
Voltage Withstandability
Insulation Resistance
Environmental Resistance: Vibration Resistance
Environmental Resistance: Shock Resistance
Material
Total Extension Distance
Communication Cable
Weight (Typ.)
Remark
Network No. Setting
Cyclic transmission (Maximum number of links per station)
Transient Transmission
Transmission line type
Maximum Transmission Distance
Max. Overall Cable & Transmission Distance
Cascade Connection Levels
Maximum Number of Connectable Controllers
Cyclic Transmission (Maximum Number Of Links Per Station)
Environmental Resistance: Voltage Withstandability
Maximum of 15 controllers (one master, 14 slaves) per SC‑HG1‑CEF unit
24V DC ±10%, including 0.5V ripple (P-P) (Note) : Power is supplied from a connected controller / master controller.
200 mA or less
CC-Link IE Field
1 Gbps
Remote device station
1 to 120 (decimal) (0 and 121 or more: Error)
2
2,000 m 6561.68 ft or less (Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
IP40 (IEC)
10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed) Storage: -20 to +60 ℃ -4 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58Hz), maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Enclosure: Polycarbonate
Ethernet cable that satisfies 1000BASE-T standard Category 5e or higher (Double-shielded / STP, straight cable) (Note) : Use CC-Link Partner Association recommended cable.
Net weight: 100 g approx., Gross weight: 150 g approx.
Where measurement conditions have not been specified precisely, the conditions used were ambient temperature +20 ℃ +68 ℉.
1 to 239 (decimal) [1 to EF (hex)] (0 and 240 or more: Error) (Note) : For the network number setting on this product, convert the network number to hex and set the hex value.
RX/RY:128 points each (128 bits), 16 bytes, RWr/RWw: 64 points each (64 words), 128 bytes
Server function only, data size 1024 bytes
Line, star, (mixing of line and star types is possible), ring
100 m 328.084 ft
121 units (1 master station, 120 slave stations)
Maximum 20
Maximum of 15 units (one master, 14 slaves) per SC‑HG1‑CEF unit
RX/RY:128 points each (128 bits), 16 bytes,
RWr/RWw: 64 points each (64 words), 128 bytes
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ or more, with 250 V DC megger between all supply
terminals connected together and enclosure
HG-SC□
Line, star, (mixing of line and star types is possible), ring
2
Net weight: 100 g approx., Gross weight: 150 g approx.
1 to 99 units when MODBUS (RTU/ASCII) is used, 1 to 64 units when MEWTOCOL-COM is used
Maximum of 15 controllers (one master, 14 slaves) per SC-HG1-485 unit
1 bit / 2 bits
Even / Odd / None
8 bits (RTU) / 7 bits (ASCII)
2
2,000 m 6561.68 ft or less (Note): Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
IP40 (IEC)
-10 to +45 ℃ 14 to +113 ℉ (No condensation or icing), Storage : -20 to +60 ℃ -4 to +140 ℉
35 to 85 % RH, Storage : 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58Hz), maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Unit case : Polycarbonate
Communication cable : 1,200 m 3,937.008 ft or less between SC-HG1-485 (terminal) and PLC
Net weight : 75 g approx., Gross weight : 120 g approx.
Where measurement conditions have not been specified precisely, the conditions used were ambient temperature +20 ℃ +68 ℉.
EMC Directive (Note), RoHS Directive (Note): If our product will be incorporated in a customer product that will comply with the EMC Directive, install our product in a conductive box in accordance with "PLC User's Manual [Published by Mitsubishi Electric Corporation]".
HG-SC□ / HG-TC□
Maximum of 15 controllers (one master, 14 slaves) per SC-HG1-C unit
24 V DC ±10 %, including ripple 0.5 V (P-P) (Note): Power is supplied from a connected controller / master controller.
・10 Mbps/100 m 328.084 ft ・5 Mbps/160 m 524.934 ft ・2.5 Mbps/400 m 1,312.336 ft ・625 kbps/900 m 2,952.756 ft ・156 kbps/1,200 m 3,937.008 ft
2
2,000 m 6561.68 ft or less (Note): Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
IP40 (IEC)
-10 to +45 ℃ +14 to +113 ℉ (No condensation or icing), Storage : -20 to +60 ℃ -4 to +140 ℉
35 to 85 % RH, Storage : 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58Hz), maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Unit case : Polycarbonate
Specified cable (shielded twisted cable) (Note): Use only a special-use communication cable that is approved by the CC-Link Partner Association.
Net weight : 80 g approx., Gross weight : 130 g approx.
Where measurement conditions have not been specified precisely, the conditions used were ambient temperature +20 ℃ +68 ℉.