Specification

Specifications table for model SC-HG1-CEF
ItemPerformance characteristics
CE Marking Directive ComplianceEMC Directive, RoHS Directive
Compatible ControllersHG-SC□ / HG-TC□
Number of Connectable UnitsMaximum of 15 controllers (one master, 14 slaves) per SC‑HG1‑CEF unit
Supply Voltage 24V DC ±10%, including 0.5V ripple (P-P)
(Note) : Power is supplied from a connected controller / master controller.
Current Consumption200 mA or less
Communication MethodCC-Link IE Field
Communication Speed1 Gbps
Remote Station TypeRemote device station
Station No. Setting1 to 120 (decimal) (0 and 121 or more: Error)
Degree of Pollution2
Operating Altitude2,000 m 6561.68 ft or less
(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
Environmental Resistance: ProtectionIP40 (IEC)
Environmental Resistance: Ambient Temperature10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed)
Storage: -20 to +60 ℃ -4 to +140 ℉
Environmental Resistance: Ambient Humidity35 to 85 % RH, Storage: 35 to 85 % RH
Voltage Withstandability1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation Resistance20 MΩ or more, with 250 V DC megger between all supply terminals connected together and enclosure
Environmental Resistance: Vibration Resistance10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58Hz), maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each
Environmental Resistance: Shock Resistance98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
MaterialEnclosure: Polycarbonate
Communication CableEthernet cable that satisfies 1000BASE-T standard Category 5e or higher (Double-shielded / STP, straight cable)
(Note) : Use CC-Link Partner Association recommended cable.
Weight (Typ.)Net weight: 100 g approx., Gross weight: 150 g approx.
RemarkWhere measurement conditions have not been specified precisely, the conditions used were ambient temperature +20 ℃ +68 ℉.
Network No. Setting 1 to 239 (decimal) [1 to EF (hex)] (0 and 240 or more: Error)
(Note) : For the network number setting on this product, convert the network number to hex and set the hex value.
Cyclic transmission (Maximum number of links per station)RX/RY:128 points each (128 bits), 16 bytes, RWr/RWw: 64 points each (64 words), 128 bytes
Transient TransmissionServer function only, data size 1024 bytes
Transmission line typeLine, star, (mixing of line and star types is possible), ring
Maximum Transmission Distance100 m 328.084 ft
Max. Overall Cable & Transmission Distance121 units (1 master station, 120 slave stations)
Cascade Connection LevelsMaximum 20
Maximum Number of Connectable Controllers Maximum of 15 units (one master, 14 slaves) per SC‑HG1‑CEF unit
Cyclic Transmission<br>(Maximum Number Of Links Per Station)RX/RY:128 points each (128 bits), 16 bytes,
RWr/RWw: 64 points each (64 words), 128 bytes
Environmental Resistance: Voltage Withstandability1,000 V AC for one min. between all supply terminals connected together and enclosure
Environmental Resistance: Insulation Resistance20 MΩ or more, with 250 V DC megger between all supply terminals connected together and enclosure
Compatible ControllerHG-SC□
Transmission Line Types Line, star, (mixing of line and star types is possible), ring
Pollution Degree 2
Net Weight Net weight: 100 g approx., Gross weight: 150 g approx.

Stock Check