Item | Performance characteristics |
---|---|
Applicable Sensor Heads | HL-D301B, HL-D301C |
Connectable sensor heads | Number of connectable units: Max. 2 units |
Supply Voltage | 24 V DC ±10 % including ripple 0.5 V (P-P) |
Current Consumption | 1 A or less (when 2 sensor heads are connected) |
Sampling Rate | Depends on the sensing mode and settings Multi-zone beam control mode : Standard 12.2 ms (Note 1) Whole synchronized measurement mode : Max. 2.5 ms (Note 2) Multi-select displacement sensing mode : Max. 80 μs (Note 3) (Note 1):Value for using two judgment outputs with 1 sensor head in MZBC mode, with each measuring range set to Max. and light intensity not adjusted (continuous sensing). (Note 2):Value for obtaining displacement shape waveform data using buffering and 2 sensor heads in whole synchronized measurement mode, with each measuring range set to Min. (no OUT calculation). (Note 3):Value for using 2 judgment outputs with 1 sensor head in MSDS mode, with the unit light receiving time set to 40 μs, light intensity not adjusted (continuous), and 2 points selected (without wide cell function). |
Judgement Output | N-channel FET, open drain • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between output terminal and 0 V) • ON-resistance: 5 Ω or less |
Judgment Output: Output Operation | Open during output operation (switchable) |
Judgment Output: Short-Circuit Protection | Incorporated |
Alarm Output | N-channel FET, open drain • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between output terminal and 0 V) • ON-resistance: 5 Ω or less |
Alarm Output : Output Operation | Open when alarm is triggered (switchable) |
Alarm Output : Short-Circuit Protection | Incorporated |
External Trigger Input | Photocoupler insulation input |
External Trigger Input: Input Operation | ON: short-circuiting to external insulation COM (-) , OFF: when open |
External Trigger Input: Applied Voltage | 30 V DC or less (leakage current: 0.1 mA or less) |
Laser Control Input | Photocoupler insulation input |
Laser Control Input: Input Operation | Laser emission: short-circuiting to external insulation COM (-) , Laser emission OFF: when open |
Laser Control Input: Applied Voltage | 30 V DC or less (leakage current: 0.1 mA or less) |
Zero Set Input | Photocoupler insulation input |
Zero Set Input: Input Operation | ON: short-circuiting to external insulation COM (-) , OFF: when open |
Zero Set Input: Applied Voltage | 30 V DC or less (leakage current: 0.1 mA or less) |
Timing Input | Photocoupler insulation input |
Timing Input: Input Operation | ON: short-circuiting to external insulation COM (-) , OFF: when open |
Timing Input: Applied Voltage | 30 V DC or less (leakage current: 0.1 mA or less) |
Reset Input | Photocoupler insulation input |
Reset Input: Input Operation | ON: short-circuiting to external insulation COM (-) , OFF: when open |
Reset Input: Applied Voltage | 30 V DC or less (leakage current: 0.1 mA or less) |
RS-232C Interface | Baud rate: 9,600, 19,200, 38,400, 57,600, 115,200 bit/s(Note):Products produced from September 2013 (Ver. 2) are also compatible with 9,600, 19,200 and 38,400 bit/s. |
Settings/Data Display | HL-D3SMI (accessory) or dedicated API |
USB Interface | USB 2.0 full-speed (USB 1.1 compatible) |
Indicator: Power | Green LED (lights up at power on) |
Indicator: Sensor Head A Laser Radiation | Green LED [During continuous sensing: lights up during laser emission, blinks twice when turning off During sensing stop process: alternately lights up during laser emission (ON: 1 sec / OFF: 1 sec), blinks once when turning off] |
Indicator: Sensor Head B Laser Radiation | Green LED [During continuous sensing: lights up during laser emission, blinks twice when turning off During sensing stop process: alternately lights up during laser emission (ON: 1 sec / OFF: 1 sec), blinks once when turning off] |
Indicator: Alarm | Red LED (lights up when there is a sensing alarm or sensor head wire breakage) |
Environmental Resistance: Ambient Temperature | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ |
Environmental Resistance: Ambient Humidity | 35 to 85 % RH , Storage: 35 to 85 % RH |
Environmental Resistance: Vibration Resistance | 10 to 55 Hz frequency (period: 1 min) , 0.75 mm 0.030 in double amplitude in X, Y, and Z directions for 30 min. each |
Environmental Resistance: Shock Resistance | 196 m/s2 acceleration (20G approx.) in X, Y, and Z directions three times each |
Material | Enclosure: Aluminum |
Weight (Typ.) | 300 g approx. |
Accessory | HL-D3 set-up CD-ROM, (including HL-D3SMI and User's Manual), Instruction manual, USB cable (2 m 6.562 ft) |
The service is owned, operated, controlled and managed by Panasonic's distributors.
For pricing, delivery and technical questions related to this service, please direct to them.
Panasonic assumes no responsibility for any dealings you may have with distributors.