Compact Multi-voltage Photoelectric Sensor NX5

The NX5 Series Compact Multi-Voltage Photoelectric Sensor can operate at 24-240VAC or 12-240VDC, which is suitable for supply voltages around the world. The long sensing range is most suitable for conveyor lines and parking loT applications. 

Part Number List

Results 20
Models table for series Compact Multi-voltage Photoelectric Sensor NX5
Part No.DatasheetCE Marking Directive ComplianceSensing Range Sensing Object HysteresisRepeatability (Perpendicular to Sensing Axis) Supply Voltage Power ConsumptionOutputOutput: Output Operation Response TimeOperation Indicator Stability IndicatorPower Indicator Sensitivity AdjusterAutomatic Interference Prevention FunctionPollution Degree Ambient TemperatureProtectionAmbient HumidityAmbient IlluminanceVoltage WithstandabilityInsulation Resistance Vibration ResistanceShock ResistanceEmitting ElementEmitting Element: Peak Emission WavelengthMaterialCableCable ExtensionWeight (Typ.)AccessoryUtilization CategoryImpulse withstand voltageOutput minimum operational currentTurn on time / Turn off timeMaximum response frequencyClass of protection against electric shockExcess gainNote
・Low Voltage Directive : EN IEC 60947-5-2
・EMC Directive : EN IEC 60947-5-2
・RoHS Directive
・GB/T 14048.10
700 mm 27.559 in
(Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.
Opaque, translucent or transparent object
(Note) Make sure to confirm detection with an actual sensor before use.
15 % or less of operation distance
(Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.
0.3 mm 0.012 in or less
24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less
2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Light-ON
10 ms or less
Red LED (lights up when the output is ON)
Green LED (lights up under stable light received condition or stable dark condition)
-
Continuously variable adjuster
Incorporated (Two units of sensors can be mounted close together.)
3 (Industrial environment)
–20 to +55 ℃ –4 to +131 ℉ (No dew condensation or icing allowed) (Note),
Storage: –30 to +70 ℃ –22 to +158 ℉
(Note):In case the sensor is to be used at an ambient temperature of –15 ℃ +5 ℉, or less, please contact our office.
IP66 (IEC)
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,500 V AC for one min. between all supply terminals connected together and enclosure,
1,500 V AC for one min. between power supply and output terminals,
1,000 V AC for one min. between relay contact terminals
20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each
500 m/s2 (50 G approx.) in X, Y and Z directions three times each
Infrared LED (modulated)
880 nm 0.035 mil
Enclosure: Polycarbonate
Lens: Polycarbonate
Cover: Polycarbonate
0.3 mm2 5-core cabtyre cable, 2 m 6.562 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable
140 g approx.
Adjusting screwdriver: 1 pc.
AC-12/DC-12
2.5kV
DC5V 1mA or more
10ms / 10ms
Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below.
50Hz
Note:The maximum response frequency is the value calculated below.
Maximum response frequency = 1 / (Turn on time+Turn off time)
Out of classification
14%
Note : Excess gain of NX-D700□ is the value in case sensitivity aduster is in maximum position.
Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
Note 2 : The output applied voltage should be the same as the supply voltage of the sensor.
Note 3 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output..
In addition, use 3A or less fast blow fuse or breaker.
・Low Voltage Directive : EN IEC 60947-5-2
・EMC Directive : EN IEC 60947-5-2
・RoHS Directive
・GB/T 14048.10
30 m 98.425 ft
dia. 20 mm dia. 0.787 in or more opaque object (Completely beam interrupted object)
(Note) If slit masks (optional) are fitted, an object as small as 3 x 6 mm 0.118 x 0.236 in can be detected.
-
0.2 mm 0.008 in or less
24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less
Emitter: 1.5 VA or less
Receiver: 2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Light-ON
10 ms or less
Red LED (lights up when the output is ON)
Green LED (lights up under stable light received condition or stable dark condition)
Red LED (lights up when the power is ON)
-
-
3 (Industrial environment)
–20 to +55 ℃ –4 to +131 ℉ (No dew condensation or icing allowed) (Note),
Storage: –30 to +70 ℃ –22 to +158 ℉
(Note):In case the sensor is to be used at an ambient temperature of –15 ℃ +5 ℉, or less, please contact our office.
IP66 (IEC)
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,500 V AC for one min. between all supply terminals connected together and enclosure,
1,500 V AC for one min. between power supply and output terminals,
1,000 V AC for one min. between relay contact terminals
20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each
500 m/s2 (50 G approx.) in X, Y and Z directions three times each
Infrared LED (modulated)
880 nm 0.035 mil
Enclosure: Polycarbonate
Lens: Polycarbonate
Cover: Polycarbonate
0.3 mm2 5-core (emitter: 2-core) cabtyre cable, 2 m 6.562 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (both emitter and receiver).
Emitter: 125 g approx
Receiver: 140 g approx
-
AC-12/DC-12
2.5kV
DC5V 1mA or more
10ms / 10ms
Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below.
50Hz
Note:The maximum response frequency is the value calculated below.
Maximum response frequency = 1 / (Turn on time+Turn off time)
Out of classification
30%
Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
Note 2 : The output applied voltage should be the same as the supply voltage of the sensor.
Note 3 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output..
In addition, use 3A or less fast blow fuse or breaker.
・Low Voltage Directive : EN IEC 60947-5-2
・EMC Directive : EN IEC 60947-5-2
・RoHS Directive
・GB/T 14048.10
30 m 98.425 ft
dia. 20 mm dia. 0.787 in or more opaque object (Completely beam interrupted object)
(Note) If slit masks (optional) are fitted, an object as small as 3 x 6 mm 0.118 x 0.236 in can be detected.
-
0.2 mm 0.008 in or less
24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less
Emitter: 1.5 VA or less
Receiver: 2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Light-ON
10 ms or less
Red LED (lights up when the output is ON)
Green LED (lights up under stable light received condition or stable dark condition)
Red LED (lights up when the power is ON)
-
-
3 (Industrial environment)
–20 to +55 ℃ –4 to +131 ℉ (No dew condensation or icing allowed) (Note),
Storage: –30 to +70 ℃ –22 to +158 ℉
(Note):In case the sensor is to be used at an ambient temperature of –15 ℃ +5 ℉, or less, please contact our office.
IP66 (IEC)
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,500 V AC for one min. between all supply terminals connected together and enclosure,
1,500 V AC for one min. between power supply and output terminals,
1,000 V AC for one min. between relay contact terminals
20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each
500 m/s2 (50 G approx.) in X, Y and Z directions three times each
Infrared LED (modulated)
880 nm 0.035 mil
Enclosure: Polycarbonate
Lens: Polycarbonate
Cover: Polycarbonate
0.3 mm2 5-core (emitter: 2-core) cabtyre cable, 2 m 6.562 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (both emitter and receiver).
-
AC-12/DC-12
2.5kV
DC5V 1mA or more
10ms / 10ms
Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below.
50Hz
Note:The maximum response frequency is the value calculated below.
Maximum response frequency = 1 / (Turn on time+Turn off time)
Out of classification
30%
Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
Note 2 : The output applied voltage should be the same as the supply voltage of the sensor.
Note 3 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output..
In addition, use 3A or less fast blow fuse or breaker.
・Low Voltage Directive : EN IEC 60947-5-2
・EMC Directive : EN IEC 60947-5-2
・RoHS Directive
・GB/T 14048.10
0.1 to 7 m 0.328 to 22.966 ft
(Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
dia. 50 mm dia. 1.969 in or more opaque or translucent object
(Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
(Note) Make sure to confirm detection with an actual sensor before use.
-
0.2 mm 0.008 in or less
24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less
2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Dark-ON
10 ms or less
Red LED (lights up when the output is ON)
Green LED (lights up under stable light received condition or stable dark condition)
-
-
Incorporated (Two units of sensors can be mounted close together.)
3 (Industrial environment)
–20 to +55 ℃ –4 to +131 ℉ (No dew condensation or icing allowed) (Note),
Storage: –30 to +70 ℃ –22 to +158 ℉
(Note):In case the sensor is to be used at an ambient temperature of –15 ℃ +5 ℉, or less, please contact our office.
IP66 (IEC)
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,500 V AC for one min. between all supply terminals connected together and enclosure,
1,500 V AC for one min. between power supply and output terminals,
1,000 V AC for one min. between relay contact terminals
20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each
500 m/s2 (50 G approx.) in X, Y and Z directions three times each
Infrared LED (modulated)
880 nm 0.035 mil
Enclosure: Polycarbonate
Lens: Polycarbonate
Cover: Polycarbonate
Front cover: Acylic
0.3 mm2 5-core cabtyre cable, 5 m 16.404 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable
RF-230 (Reflector): 1 pc.
AC-12/DC-12
2.5kV
DC5V 1mA or more
10ms / 10ms
Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below.
50Hz
Note:The maximum response frequency is the value calculated below.
Maximum response frequency = 1 / (Turn on time+Turn off time)
Out of classification
10%
Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
Note 2 : The output applied voltage should be the same as the supply voltage of the sensor.
Note 3 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output..
In addition, use 3A or less fast blow fuse or breaker.
・Low Voltage Directive : EN IEC 60947-5-2
・EMC Directive : EN IEC 60947-5-2
・RoHS Directive
・GB/T 14048.10
10 m 32.808 ft
dia. 20 mm dia. 0.787 in or more opaque object
(Note) If slit masks (optional) are fitted, an object as small as 3 x 6 mm 0.118 x 0.236 in can be detected.
-
0.1 mm 0.004 in or less
24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less
Emitter: 1 VA or less
Receiver: 2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Light-ON
10 ms or less
Red LED (lights up when the output is ON)
Green LED (lights up under stable light received condition or stable dark condition)
-
Continuously variable adjuster
(Use optional interference prevention filters)
3 (Industrial environment)
–20 to +55 ℃ –4 to +131 ℉ (No dew condensation or icing allowed) (Note),
Storage: –30 to +70 ℃ –22 to +158 ℉
(Note):In case the sensor is to be used at an ambient temperature of –15 ℃ +5 ℉, or less, please contact our office.
IP66 (IEC)
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,500 V AC for one min. between all supply terminals connected together and enclosure,
1,500 V AC for one min. between power supply and output terminals,
1,000 V AC for one min. between relay contact terminals
20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each
500 m/s2 (50 G approx.) in X, Y and Z directions three times each
Red LED (modulated)
660 nm 0.026 mil
Enclosure: Polycarbonate
Lens: Polycarbonate
Cover: Polycarbonate
0.3 mm2 5-core (emitter: 2-core) cabtyre cable, 2 m 6.562 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (both emitter and receiver).
Emitter: 100 g approx
Receiver: 140 g approx
Adjusting screwdriver: 1 pc.
AC-12/DC-12
2.5kV
DC5V 1mA or more
10ms / 10ms
Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below.
50Hz
Note:The maximum response frequency is the value calculated below.
Maximum response frequency = 1 / (Turn on time+Turn off time)
Out of classification
30%
Note : Excess gain of NX5-M10□ is the value in case sensitivity aduster is in maximum position.
Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
Note 2 : The output applied voltage should be the same as the supply voltage of the sensor.
Note 3 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output..
In addition, use 3A or less fast blow fuse or breaker.
・Low Voltage Directive : EN IEC 60947-5-2
・EMC Directive : EN IEC 60947-5-2
・RoHS Directive
・GB/T 14048.10
0.1 to 5 m 0.328 to 16.404 ft
(Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
dia. 50 mm dia. 1.969 in or more opaque, translucent or specular object
(Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
(Note) Make sure to confirm detection with an actual sensor before use.
-
0.2 mm 0.008 in or less
24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less
2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Dark-ON
10 ms or less
Red LED (lights up when the output is ON)
Green LED (lights up under stable light received condition or stable dark condition)
-
Continuously variable adjuster
Incorporated (Two units of sensors can be mounted close together.)
3 (Industrial environment)
–20 to +55 ℃ –4 to +131 ℉ (No dew condensation or icing allowed) (Note),
Storage: –30 to +70 ℃ –22 to +158 ℉
(Note):In case the sensor is to be used at an ambient temperature of –15 ℃ +5 ℉, or less, please contact our office.
IP66 (IEC)
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,500 V AC for one min. between all supply terminals connected together and enclosure,
1,500 V AC for one min. between power supply and output terminals,
1,000 V AC for one min. between relay contact terminals
20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each
500 m/s2 (50 G approx.) in X, Y and Z directions three times each
Red LED (modulated)
660 nm 0.026 mil
Enclosure: Polycarbonate
Lens: Polycarbonate
Cover: Polycarbonate
Front cover: Acylic
0.3 mm2 5-core cabtyre cable, 2 m 6.562 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable
140 g approx.
RF-230 (Reflector): 1 pc
Adjusting screwdriver: 1 pc
AC-12/DC-12
2.5kV
DC5V 1mA or more
10ms / 10ms
Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below.
50Hz
Note:The maximum response frequency is the value calculated below.
Maximum response frequency = 1 / (Turn on time+Turn off time)
Out of classification
10%
Note : Excess gain of NX5-PRVM5□ is the value in case sensitivity aduster is in maximum position.
Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
Note 2 : The output applied voltage should be the same as the supply voltage of the sensor.
Note 3 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output..
In addition, use 3A or less fast blow fuse or breaker.
・Low Voltage Directive : EN IEC 60947-5-2
・EMC Directive : EN IEC 60947-5-2
・RoHS Directive
・GB/T 14048.10
0.1 to 5 m 0.328 to 16.404 ft
(Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
dia. 50 mm dia. 1.969 in or more opaque, translucent or specular object
(Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
(Note) Make sure to confirm detection with an actual sensor before use.
-
0.2 mm 0.008 in or less
24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less
2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Dark-ON
10 ms or less
Red LED (lights up when the output is ON)
Green LED (lights up under stable light received condition or stable dark condition)
-
Continuously variable adjuster
Incorporated (Two units of sensors can be mounted close together.)
3 (Industrial environment)
–20 to +55 ℃ –4 to +131 ℉ (No dew condensation or icing allowed) (Note),
Storage: –30 to +70 ℃ –22 to +158 ℉
(Note):In case the sensor is to be used at an ambient temperature of –15 ℃ +5 ℉, or less, please contact our office.
IP66 (IEC)
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,500 V AC for one min. between all supply terminals connected together and enclosure,
1,500 V AC for one min. between power supply and output terminals,
1,000 V AC for one min. between relay contact terminals
20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each
500 m/s2 (50 G approx.) in X, Y and Z directions three times each
Red LED (modulated)
660 nm 0.026 mil
Enclosure: Polycarbonate
Lens: Polycarbonate
Cover: Polycarbonate
Front cover: Acylic
0.3 mm2 5-core cabtyre cable, 5 m 16.404 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable
RF-230 (Reflector): 1 pc
Adjusting screwdriver: 1 pc
AC-12/DC-12
2.5kV
DC5V 1mA or more
10ms / 10ms
Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below.
50Hz
Note:The maximum response frequency is the value calculated below.
Maximum response frequency = 1 / (Turn on time+Turn off time)
Out of classification
10%
Note : Excess gain of NX5-PRVM5□ is the value in case sensitivity aduster is in maximum position.
Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
Note 2 : The output applied voltage should be the same as the supply voltage of the sensor.
Note 3 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output..
In addition, use 3A or less fast blow fuse or breaker.
・Low Voltage Directive : EN IEC 60947-5-2
・EMC Directive : EN IEC 60947-5-2
・RoHS Directive
・GB/T 14048.10
700 mm 27.559 in
(Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.
Opaque, translucent or transparent object
(Note) Make sure to confirm detection with an actual sensor before use.
15 % or less of operation distance
(Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.
0.3 mm 0.012 in or less
24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less
2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Dark-ON
10 ms or less
Red LED (lights up when the output is ON)
Green LED (lights up under stable light received condition or stable dark condition)
-
Continuously variable adjuster
Incorporated (Two units of sensors can be mounted close together.)
3 (Industrial environment)
–20 to +55 ℃ –4 to +131 ℉ (No dew condensation or icing allowed) (Note),
Storage: –30 to +70 ℃ –22 to +158 ℉
(Note):In case the sensor is to be used at an ambient temperature of –15 ℃ +5 ℉, or less, please contact our office.
IP66 (IEC)
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,500 V AC for one min. between all supply terminals connected together and enclosure,
1,500 V AC for one min. between power supply and output terminals,
1,000 V AC for one min. between relay contact terminals
20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each
500 m/s2 (50 G approx.) in X, Y and Z directions three times each
Infrared LED (modulated)
880 nm 0.035 mil
Enclosure: Polycarbonate
Lens: Polycarbonate
Cover: Polycarbonate
0.3 mm2 5-core cabtyre cable, 5 m 16.404 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable
Adjusting screwdriver: 1 pc.
AC-12/DC-12
2.5kV
DC5V 1mA or more
10ms / 10ms
Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below.
50Hz
Note:The maximum response frequency is the value calculated below.
Maximum response frequency = 1 / (Turn on time+Turn off time)
Out of classification
14%
Note : Excess gain of NX-D700□ is the value in case sensitivity aduster is in maximum position.
Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
Note 2 : The output applied voltage should be the same as the supply voltage of the sensor.
Note 3 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output..
In addition, use 3A or less fast blow fuse or breaker.
・Low Voltage Directive : EN IEC 60947-5-2
・EMC Directive : EN IEC 60947-5-2
・RoHS Directive
・GB/T 14048.10
700 mm 27.559 in
(Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.
Opaque, translucent or transparent object
(Note) Make sure to confirm detection with an actual sensor before use.
15 % or less of operation distance
(Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.
0.3 mm 0.012 in or less
24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less
2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Light-ON
10 ms or less
Red LED (lights up when the output is ON)
Green LED (lights up under stable light received condition or stable dark condition)
-
Continuously variable adjuster
Incorporated (Two units of sensors can be mounted close together.)
3 (Industrial environment)
–20 to +55 ℃ –4 to +131 ℉ (No dew condensation or icing allowed) (Note),
Storage: –30 to +70 ℃ –22 to +158 ℉
(Note):In case the sensor is to be used at an ambient temperature of –15 ℃ +5 ℉, or less, please contact our office.
IP66 (IEC)
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,500 V AC for one min. between all supply terminals connected together and enclosure,
1,500 V AC for one min. between power supply and output terminals,
1,000 V AC for one min. between relay contact terminals
20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each
500 m/s2 (50 G approx.) in X, Y and Z directions three times each
Infrared LED (modulated)
880 nm 0.035 mil
Enclosure: Polycarbonate
Lens: Polycarbonate
Cover: Polycarbonate
0.3 mm2 5-core cabtyre cable, 5 m 16.404 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable
Adjusting screwdriver: 1 pc.
AC-12/DC-12
2.5kV
DC5V 1mA or more
10ms / 10ms
Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below.
50Hz
Note:The maximum response frequency is the value calculated below.
Maximum response frequency = 1 / (Turn on time+Turn off time)
Out of classification
14%
Note : Excess gain of NX-D700□ is the value in case sensitivity aduster is in maximum position.
Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
Note 2 : The output applied voltage should be the same as the supply voltage of the sensor.
Note 3 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output..
In addition, use 3A or less fast blow fuse or breaker.
・Low Voltage Directive : EN IEC 60947-5-2
・EMC Directive : EN IEC 60947-5-2
・RoHS Directive
・GB/T 14048.10
700 mm 27.559 in
(Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.
Opaque, translucent or transparent object
(Note) Make sure to confirm detection with an actual sensor before use.
15 % or less of operation distance
(Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.
0.3 mm 0.012 in or less
24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less
2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Dark-ON
10 ms or less
Red LED (lights up when the output is ON)
Green LED (lights up under stable light received condition or stable dark condition)
-
Continuously variable adjuster
Incorporated (Two units of sensors can be mounted close together.)
3 (Industrial environment)
–20 to +55 ℃ –4 to +131 ℉ (No dew condensation or icing allowed) (Note),
Storage: –30 to +70 ℃ –22 to +158 ℉
(Note):In case the sensor is to be used at an ambient temperature of –15 ℃ +5 ℉, or less, please contact our office.
IP66 (IEC)
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,500 V AC for one min. between all supply terminals connected together and enclosure,
1,500 V AC for one min. between power supply and output terminals,
1,000 V AC for one min. between relay contact terminals
20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each
500 m/s2 (50 G approx.) in X, Y and Z directions three times each
Infrared LED (modulated)
880 nm 0.035 mil
Enclosure: Polycarbonate
Lens: Polycarbonate
Cover: Polycarbonate
0.3 mm2 5-core cabtyre cable, 2 m 6.562 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable
140 g approx.
Adjusting screwdriver: 1 pc.
AC-12/DC-12
2.5kV
DC5V 1mA or more
10ms / 10ms
Note : Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below.
50Hz
Note:The maximum response frequency is the value calculated below.
Maximum response frequency = 1 / (Turn on time+Turn off time)
Out of classification
14%
Note : Excess gain of NX-D700□ is the value in case sensitivity aduster is in maximum position.
Note 1 : Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
Note 2 : The output applied voltage should be the same as the supply voltage of the sensor.
Note 3 : Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output..
In addition, use 3A or less fast blow fuse or breaker.