Item | Performance characteristics |
---|---|
CE Marking Directive Compliance | EMC Directive, RoHS Directive |
Sensing Range | 0.1 to 2 m 0.328 to 6.562 ft (Note) The sensing range and the sensing object are specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. |
Sensing Object | dia. 50 mm dia. 1.969 in or more opaque, translucent or specular object (Note) The sensing range and the sensing object are specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. (Note) Make sure to confirm detection with an actual sensor before use. |
Hysteresis | - |
Repeatability (Perpendicular to Sensing Axis) | 1 mm 0.039 in or less |
Supply Voltage | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
Current Consumption | 1 mA or less (Note) It is the leakage current when the output is in the OFF state. |
Sensing Output | Non contact DC 2-wire type - Load current: 5 to 100 mA - Residual voltage: 4 V or less (Note) (Note) When extending the cable, the residual voltage will be increased depending on the type of cable used. Verify the residual voltage when extending the cable. |
Sensing Output: Output Operation | Switchable either Light-ON or Dark-ON |
Sensing Output: Short-Circuit Protection | Incorporated |
Response Time | 3 ms or less |
Stability Indicator | Green LED (Light-ON mode: lights up under stable light received condition, Dark-ON mode: lights up under stable dark condition) |
Operation Indicator | Red LED (lights up when the output is ON) |
Emitting Indicator | - |
Sensitivity Adjuster | Continuously variable adjuster |
Protection | IP67 (IEC) |
Ambient Temperature | -20 to +60 degrees -4 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit |
Ambient Humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient Illuminance | Incandescent light: 3,500 Lx or less at the light-receiving face |
Voltage Withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation Resistance | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Vibration Resistance | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each |
Shock Resistance | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each |
Material | Enclosure: Die-cast zinc alloy Indicator cover: Polyethersulphone Lens: Acrylic |
Cable | 0.15 mm2 2-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long |
Cable Extension | - (Note) When extending the cable, the residual voltage will be increased depending on the type of cable used. Verify the residual voltage when extending the cable. |
Weight (Typ.) | 75 g approx. |
Accessory | MS-RX-1 (Sensor mounting bracket): 1 set RF-230 (Reflector): 1 pc Adjusting screwdriver: 1 pc |
Emitting Element | Red LED (modulated) |
Emitting Element: Peak Emission Wavelength | 680 nm 0.027 mil |