Combining Panasonic's accumulated know-how in measurement technology with the latest digital technology, Panasonic has created the versatile Laser Displacement Sensor HL-C2. The HL-C2 Sensor functions stably and consistently, even for extremely difficult applications such as measuring variations in HDD surfaces or sensing very shiny objects. By using Panasonic's unique new optical system, high density light-receiving cells and a cutting-edge sampling technology, a wider variety of objects can now be measured with greater precision, stability, and speed than ever before.
Characteristics
Resolution Up To 0.01μm, Regardless Of Sampling Frequency
Sampling Frequency Up To 100kHz
Unaffected By Color Or Surface Condition Of The Object
Small Beam Spot Type: ø20μm To ø400μm / Linear Beam Spot Type: 20x700μm to 400x6500μm
Linearity Error, Max ±0.02% F.S.
Compact Design
Sensing Range From 10mm ± 1mm Up To 350 ± 200mm
HL-C2 Controller
The compact and multi-functional HL-C2C Controller unit shows how powerful this new Sensor Series is. A flexible combination of Controller and Sensor heads allows cost-effective service and maintenance. The Controller can use measurements taken by the two Sensors to instantaneously calculate critical values. The compact touch panel, which is extremely easy to operate, can, in turn, display such critical values or be used in combination with the Controller to calculate results, e.g. for thickness or difference measurement. Moreover, all adjustments and results can be transmitted via USB 2.0, RS232C or Ethernet to a normal PC.
24 V DC plus or minus 10 % including ripple 0.5 V (P-P)
500 mA approx. at 2 sensor heads connected 350 mA approx. at 1 sensor head connected (100 mA approx. is additionally required when the mini console is connected)
Voltage output scale: -5 to +5 V / F.S (initial value) Output range during normal status: -10.0 to +10.0 V Output at abnormal status: -10.8 V or +10.8 V Resolution: 2 mV Linearity: plus or minus 0.05 % F.S. Max. 2 mA, output impedance 50 Ohm Response delay time: 1.5 micro s / V approx. (Note) The linearity is F.S.=20 V to digital measurement value. Response delay time is the period after update of measurement value.
Current output scale: 4 to 20 mA / F.S (initial value) Output range during normal status: 2 to 24 mA Output at abnormal status: 1 mA or 25 mA Resolution: 3 micro A, Linearity plus or minus 0.05% F.S. Load impedance: 250 Ohm max. Response delay time: 10 micro s approx. (Note) The linearity is F.S.=16 mA to digital measurement value. Response delay time is the period after update of measurement value.
PNP open-collector transistor - Maximum source current: 100 mA - Applied voltage: 30 V DC or less (between each output and +V) - Residual voltage: 1 V or less (at 100 mA source current)
Opened when the amount of light is insufficient
Incorporated
PNP open-collector transistor - Maximum source current: 100 mA - Applied voltage: 30 V DC or less (between each output and +V) - Residual voltage: 1 V or less (at 100 mA source current)
Opened at output operation
Incorporated
PNP open-collector transistor - Maximum source current: 100 mA - Applied voltage: 30 V DC or less (between each output and +V) - Residual voltage: 1 V or less (at 100 mA source current)
Opened at data determination
Incorporated
PNP open-collector transistor - Laser emission is delayed when connected to IL (+). - Laser emission stops at open - Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
PNP open-collector transistor - Laser emission is stopped when connected to external power (+). - Laser is emitted immediately after opened. - Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
PNP open-collector transistor - Zero set is ON when connected with external power (+). - Zero set turns to OFF after continuously connected to external power (+) for one second. - Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
PNP open-collector transistor - ON at / during connection to external power (+)(depending on analysis mode) - Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
PNP open-collector transistor - Reset is done when connected to external power (+). - Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
PNP open-collector transistor - Memory is specified when connected to external power (+). - Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
USB 2.0 Full-speed (USB 1.1 compatible) compliant
Compact console (optional)
Green LED (lights up at power on)
Green LED (lights up during or immediately before laser emission of sensor head A)
Green LED (lights up during or immediately before laser emission of sensor head B)
Red LED (lights up when OUT1 can not be measured due to insufficient amount of light)
Red LED (lights up when OUT2 can not be measured due to insufficient amount of light)
0 to +50 degrees +32 to +122 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
35 to 85 %RH
10 to 55 Hz frequency (period: 1 min.), 0.75 mm 0.030 in amplitude in X, Y and Z directions for 30 min. each
196 m / s2 acceleration (20G approx.) in X, Y, and Z directions for three times each
Case: Polycarbonate
450 g approx.
USB cable (2 m 6.562 ft long): 1 pc. Short bracket: 1 pc. Ferrite cores (E04SR200935A, by Seiwa Electric Mfg. Co., Ltd.): 3 pcs
24 V DC plus or minus 10 % including ripple 0.5 V (P-P)
500 mA approx. at 2 sensor heads connected 350 mA approx. at 1 sensor head connected (100 mA approx. is additionally required when the mini console is connected)
Voltage output scale: -5 to +5 V/F.S (initial value) Output range during normal status: -10.0 to +10.0 V Output at abnormal status: -10.8 V or +10.8 V Resolution: 2 mV, Linearity: plus or minus 0.05 % F.S. Max. 2 mA, output impedance 50 Ohm , Response delay time: 1.5 micro s/V approx. (Note) The linearity is F.S.=20 V to digital measurement value. Response delay time is the period after update of measurement value.
Current output scale: 4 to 20 mA/F.S (initial value) Output range during normal status: 2 to 24 mA Output at abnormal status: 1 mA or 25 mA Resolution: 3 micro A, Linearity plus or minus 0.05% F.S. Load impedance: 250 Ohm max., Response delay time: 10 micro s approx. (Note) The linearity is F.S.=16 mA to digital measurement value. Response delay time is the period after update of measurement value.
NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less[between alarm output and Common(-)] - Residual voltage: 1 V or less(at 100 mA sink current)
Opened when the amount of light is insufficient
Incorporated
NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less[between judgment output to Common(-)] - Residual voltage: 1 V or less(at 100 mA sink current)
Opened at output operation
Incorporated
NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less[between strobe output to Common(-)] - Residual voltage: 1 V or less(at 100 mA sink current)
Opened at data determination
Incorporated
Laser emission is delayed when connected to Common (-). Laser emission stop at open Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Laser emission is stopped when connected to Common (-). Laser is emitted immediately after opened. Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Zero set is ON when connected with Common (-). Zero set turns to OFF after continuously connected to Common (-) for one second. Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
ON at/during connection to Common (-)(depending on analysis mode) Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Reset is done when connected to Common (-). Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Memory is specified when connected to Common (-). Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Green LED (lights up at power on)
Green LED (lights up during or immediately before laser emission of sensor head A)
Green LED (lights up during or immediately before laser emission of sensor head B)
Red LED (lights up when OUT1 can not be measured due to insufficient amount of light)
Red LED (lights up when OUT2 can not be measured due to insufficient amount of light)
0 to +50 degrees +32 to +122 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
35 to 85 %RH
10 to 55 Hz frequency (period: 1 min.), 0.75 mm 0.030 in amplitude in X, Y and Z directions for 30 min. each
196 m/s2 acceleration (20 G approx.) in X,Y and Z directions for three times each
Case: Polycarbonate
450 g approx.
USB cable (2 m 6.562 ft long): 1 pc. Short bracket: 1 pc.
24 V DC plus or minus 10 % including ripple 0.5 V (P-P)
500 mA approx. at 2 sensor heads connected 350 mA approx. at 1 sensor head connected (100 mA approx. is additionally required when the mini console is connected)
Voltage output scale: -5 to +5 V/F.S (initial value) Output range during normal status: -10.0 to +10.0 V Output at abnormal status: -10.8 V or +10.8 V Resolution: 2 mV, Linearity: plus or minus 0.05 % F.S. Max. 2 mA, output impedance 50 Ohm , Response delay time: 1.5 micro s/V approx. (Note) The linearity is F.S.=20 V to digital measurement value. Response delay time is the period after update of measurement value.
Current output scale: 4 to 20 mA/F.S (initial value) Output range during normal status: 2 to 24 mA Output at abnormal status: 1 mA or 25 mA Resolution: 3 micro A, Linearity plus or minus 0.05% F.S. Load impedance: 250 Ohm max., Response delay time: 10 micro s approx. (Note) The linearity is F.S.=16 mA to digital measurement value. Response delay time is the period after update of measurement value.
NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less[between alarm output and Common(-)] - Residual voltage: 1 V or less(at 100 mA sink current)
Opened when the amount of light is insufficient
Incorporated
NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less[between judgment output to Common(-)] - Residual voltage: 1 V or less(at 100 mA sink current)
Opened at output operation
Incorporated
NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less[between strobe output to Common(-)] - Residual voltage: 1 V or less(at 100 mA sink current)
Opened at data determination
Incorporated
Laser emission is delayed when connected to Common (-). Laser emission stop at open Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Laser emission is stopped when connected to Common (-). Laser is emitted immediately after opened. Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Zero set is ON when connected with Common (-). Zero set turns to OFF after continuously connected to Common (-) for one second. Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
ON at/during connection to Common (-)(depending on analysis mode) Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Reset is done when connected to Common (-). Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Memory is specified when connected to Common (-). Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Green LED (lights up at power on)
Green LED (lights up during or immediately before laser emission of sensor head A)
Green LED (lights up during or immediately before laser emission of sensor head B)
Red LED (lights up when OUT1 can not be measured due to insufficient amount of light)
Red LED (lights up when OUT2 can not be measured due to insufficient amount of light)
0 to +50 degrees +32 to +122 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
35 to 85 %RH
10 to 55 Hz frequency (period: 1 min.), 0.75 mm 0.030 in amplitude in X, Y and Z directions for 30 min. each
196 m/s2 acceleration (20 G approx.) in X,Y and Z directions for three times each
Case: Polycarbonate
450 g approx.
USB cable (2 m 6.562 ft long): 1 pc. Short bracket: 1 pc.
24 V DC plus or minus 10 % including ripple 0.5 V (P-P)
500 mA approx. at 2 sensor heads connected 350 mA approx. at 1 sensor head connected (100 mA approx. is additionally required when the mini console is connected)
Voltage output scale: -5 to +5 V / F.S (initial value) Output range during normal status: -10.0 to +10.0 V Output at abnormal status: -10.8 V or +10.8 V Resolution: 2 mV Linearity: plus or minus 0.05 % F.S. Max. 2 mA, output impedance 50 Ohm Response delay time: 1.5 micro s / V approx. (Note) The linearity is F.S.=20 V to digital measurement value. Response delay time is the period after update of measurement value.
Current output scale: 4 to 20 mA / F.S (initial value) Output range during normal status: 2 to 24 mA Output at abnormal status: 1 mA or 25 mA Resolution: 3 micro A, Linearity plus or minus 0.05% F.S. Load impedance: 250 Ohm max. Response delay time: 10 micro s approx. (Note) The linearity is F.S.=16 mA to digital measurement value. Response delay time is the period after update of measurement value.
PNP open-collector transistor - Maximum source current: 100 mA - Applied voltage: 30 V DC or less (between each output and +V) - Residual voltage: 1 V or less (at 100 mA source current)
Opened when the amount of light is insufficient
Incorporated
PNP open-collector transistor - Maximum source current: 100 mA - Applied voltage: 30 V DC or less (between each output and +V) - Residual voltage: 1 V or less (at 100 mA source current)
Opened at output operation
Incorporated
PNP open-collector transistor - Maximum source current: 100 mA - Applied voltage: 30 V DC or less (between each output and +V) - Residual voltage: 1 V or less (at 100 mA source current)
Opened at data determination
Incorporated
PNP open-collector transistor - Laser emission is delayed when connected to IL (+). - Laser emission stops at open - Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
PNP open-collector transistor - Laser emission is stopped when connected to external power (+). - Laser is emitted immediately after opened. - Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
PNP open-collector transistor - Zero set is ON when connected with external power (+). - Zero set turns to OFF after continuously connected to external power (+) for one second. - Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
PNP open-collector transistor - ON at / during connection to external power (+)(depending on analysis mode) - Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
PNP open-collector transistor - Reset is done when connected to external power (+). - Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
PNP open-collector transistor - Memory is specified when connected to external power (+). - Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
USB 2.0 Full-speed (USB 1.1 compatible) compliant
Compact console (optional)
Green LED (lights up at power on)
Green LED (lights up during or immediately before laser emission of sensor head A)
Green LED (lights up during or immediately before laser emission of sensor head B)
Red LED (lights up when OUT1 can not be measured due to insufficient amount of light)
Red LED (lights up when OUT2 can not be measured due to insufficient amount of light)
0 to +50 degrees +32 to +122 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
35 to 85 %RH
10 to 55 Hz frequency (period: 1 min.), 0.75 mm 0.030 in amplitude in X, Y and Z directions for 30 min. each
196 m / s2 acceleration (20G approx.) in X, Y, and Z directions for three times each
Case: Polycarbonate
450 g approx.
USB cable (2 m 6.562 ft long): 1 pc. Short bracket: 1 pc. Ferrite cores (E04SR200935A, by Seiwa Electric Mfg. Co., Ltd.): 3 pcs
24 V DC plus or minus 10 % including ripple 0.5 V (P-P)
500 mA approx. at 2 sensor heads connected 350 mA approx. at 1 sensor head connected (100 mA approx. is additionally required when the mini console is connected)
Voltage output scale: -5 to +5 V/F.S (initial value) Output range during normal status: -10.0 to +10.0 V Output at abnormal status: -10.8 V or +10.8 V Resolution: 2 mV, Linearity: plus or minus 0.05 % F.S. Max. 2 mA, output impedance 50 Ohm , Response delay time: 1.5 micro s/V approx. (Note) The linearity is F.S.=20 V to digital measurement value. Response delay time is the period after update of measurement value.
Current output scale: 4 to 20 mA/F.S (initial value) Output range during normal status: 2 to 24 mA Output at abnormal status: 1 mA or 25 mA Resolution: 3 micro A, Linearity plus or minus 0.05% F.S. Load impedance: 250 Ohm max., Response delay time: 10 micro s approx. (Note) The linearity is F.S.=16 mA to digital measurement value. Response delay time is the period after update of measurement value.
NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less[between alarm output and Common(-)] - Residual voltage: 1 V or less(at 100 mA sink current)
Opened when the amount of light is insufficient
Incorporated
NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less[between judgment output to Common(-)] - Residual voltage: 1 V or less(at 100 mA sink current)
Opened at output operation
Incorporated
NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less[between strobe output to Common(-)] - Residual voltage: 1 V or less(at 100 mA sink current)
Opened at data determination
Incorporated
Laser emission is delayed when connected to Common (-). Laser emission stop at open Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Laser emission is stopped when connected to Common (-). Laser is emitted immediately after opened. Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Zero set is ON when connected with Common (-). Zero set turns to OFF after continuously connected to Common (-) for one second. Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
ON at/during connection to Common (-)(depending on analysis mode) Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Reset is done when connected to Common (-). Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Memory is specified when connected to Common (-). Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Green LED (lights up at power on)
Green LED (lights up during or immediately before laser emission of sensor head A)
Green LED (lights up during or immediately before laser emission of sensor head B)
Red LED (lights up when OUT1 can not be measured due to insufficient amount of light)
Red LED (lights up when OUT2 can not be measured due to insufficient amount of light)
0 to +50 degrees +32 to +122 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
35 to 85 %RH
10 to 55 Hz frequency (period: 1 min.), 0.75 mm 0.030 in amplitude in X, Y and Z directions for 30 min. each
196 m/s2 acceleration (20 G approx.) in X,Y and Z directions for three times each
Case: Polycarbonate
450 g approx.
USB cable (2 m 6.562 ft long): 1 pc. Short bracket: 1 pc.
24 V DC plus or minus 10 % including ripple 0.5 V (P-P)
500 mA approx. at 2 sensor heads connected 350 mA approx. at 1 sensor head connected (100 mA approx. is additionally required when the mini console is connected)
Voltage output scale: -5 to +5 V/F.S (initial value) Output range during normal status: -10.0 to +10.0 V Output at abnormal status: -10.8 V or +10.8 V Resolution: 2 mV, Linearity: plus or minus 0.05 % F.S. Max. 2 mA, output impedance 50 Ohm , Response delay time: 1.5 micro s/V approx. (Note) The linearity is F.S.=20 V to digital measurement value. Response delay time is the period after update of measurement value.
Current output scale: 4 to 20 mA/F.S (initial value) Output range during normal status: 2 to 24 mA Output at abnormal status: 1 mA or 25 mA Resolution: 3 micro A, Linearity plus or minus 0.05% F.S. Load impedance: 250 Ohm max., Response delay time: 10 micro s approx. (Note) The linearity is F.S.=16 mA to digital measurement value. Response delay time is the period after update of measurement value.
NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less[between alarm output and Common(-)] - Residual voltage: 1 V or less(at 100 mA sink current)
Opened when the amount of light is insufficient
Incorporated
NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less[between judgment output to Common(-)] - Residual voltage: 1 V or less(at 100 mA sink current)
Opened at output operation
Incorporated
NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less[between strobe output to Common(-)] - Residual voltage: 1 V or less(at 100 mA sink current)
Opened at data determination
Incorporated
Laser emission is delayed when connected to Common (-). Laser emission stop at open Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Laser emission is stopped when connected to Common (-). Laser is emitted immediately after opened. Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Zero set is ON when connected with Common (-). Zero set turns to OFF after continuously connected to Common (-) for one second. Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
ON at/during connection to Common (-)(depending on analysis mode) Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Reset is done when connected to Common (-). Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Memory is specified when connected to Common (-). Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Green LED (lights up at power on)
Green LED (lights up during or immediately before laser emission of sensor head A)
Green LED (lights up during or immediately before laser emission of sensor head B)
Red LED (lights up when OUT1 can not be measured due to insufficient amount of light)
Red LED (lights up when OUT2 can not be measured due to insufficient amount of light)
0 to +50 degrees +32 to +122 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
35 to 85 %RH
10 to 55 Hz frequency (period: 1 min.), 0.75 mm 0.030 in amplitude in X, Y and Z directions for 30 min. each
196 m/s2 acceleration (20 G approx.) in X,Y and Z directions for three times each
Case: Polycarbonate
450 g approx.
USB cable (2 m 6.562 ft long): 1 pc. Short bracket: 1 pc.
You May Also Be Interested In Time of Flight (ToF) Camera Sensors
Instantly Detect Distance With Time of Flight (ToF) Camera Sensors
Panasonic Time of Flight (ToF) Cameras are compact, real-time, sensing cameras based on the ToF principle. Available in indoor and outdoor models, these cameras instantly detect distance between the camera and the targeted object with depth, infrared, and color (RGB) images. The GC1 indoor model produces RGB (640x480), depth map (320x240) (640x480) images. As well, engineers no longer need separate cameras for the depth, IR, and color images with 14/16/36 bit data formats. The HC4W outdoor model has a wide 90° FOV and is used in various applications such as security, autonomous vehicles and robotics.