Micro-differential Pressure High-precision Digital Pressure Sensor [For Gas] DP-M

Digital Differential Pressure Sensors

Due to differential pressure sensing, the pressure can be set with a high resolution of 0.01kPa over a pressure range of 0 to 2.00kPa. Three large, red, 7-segment LEDs are incorporated into a compact body and can easily be read, even in well lit places.

Characteristics

  • Analog Current Output Type 4-20mA (DPM2A)
  • High Resolution
  • High Accuracy
  • Zero-Point Adjustment
  • Two Output Modes
  • Bright LED Display
  • Compact Design

I/O Circuit and Wiring Diagrams

18

Part Number List

Results 2
Models table for series Micro-differential Pressure High-precision Digital Pressure Sensor [For Gas] DP-M
Part No.DatasheetCE Marking Directive ComplianceType of Pressure Rated Pressure Range Set Pressure Range Set Pressure ResolutionPressure WithstandabilityApplicable FluidSelectable UnitsSupply Voltage Current ConsumptionComparative OutputComparative Output: Utilization CategoryComparative Output: Output OperationComparative output: HysteresisComparative Output: RepeatabilityComparative Output: Response TimeComparative Output: Short-Circuit ProtectionAnalog Current OutputDisplayDisplay: Displayable Pressure RangeIndicators: OperationIndicators: Pressure UnitIndicators: M1 SettingIndicators: M2 Setting Pollution Degree Ambient TemperatureAmbient HumidityVoltage WithstandabilityInsulation Resistance Vibration ResistanceShock ResistanceTemperature Characteristics Pressure Port MaterialCableCable ExtensionWeight (Typ.)Remark
EMC Directive, RoHS Directive
Differential pressure
0 to 2.00 kPa.D {0 to 204 mmH2O.D}
0 to 2.00 kPa.D {0 to 204 mmH2O.D}
0.01 kPa.D {1 mmH2O.D}
6 kPa.D {612 mmH2O.D}
Non-corrosive gas
kPa, mmH2O
12 to 24 V DC +10/-15% Ripple P-P 10 % or less
75 mA or less
NPN open-collector transistor
・Maximum sink current : 100 mA
・Applied voltage : 30 V DC or less (between comparative output and 0 V)
・Residual voltage : 1 V or less (at 100 mA sink current)
0.4 V or less (at 16 mA sink current)
DC-12 or DC-13
Selectable either normally open (NO) or normally closed (NC) by the key
0.01 kPa.D {1 mmH2O.D}
Within ±1 % F.S.
10 ms or less
Incorporated
Output current : 4 to 20 mA (from 0 to 1.96 kPa.D {0 to 200 mmH2O.D})
Zero-point : within 4 mA ± 1 % F.S.
Span : within 16 mA ± 3 % F.S.
Linearity : within ±1 % F.S.
Load resistance : 0 to 250 Ω
3 digit red LED display (Sampling rate : 4 times/sec. approx.)
-0.05 to 2.10 kPa.D {-5 to 210 mmH2O.D}
Orange LED (lights up when the comparative output is ON)
Red LED (The indicator corresponding to the selected unit lights up during the sensing mode.)
Red LED (blinks in the M1 setting mode)
Red LED (blinks in the M2 setting mode)
3 (Industrial environment)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed),
Storage: -10 to +60 ℃ +14 to +140 ℉
35 to 85 % RH, Storage : 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Over ambient temperature range 0 to +50 ℃ +32 to +122 ℉
: within ±3 % F.S. of detected pressure at +25 ℃ +77 ℉
ø4.6 mm ø0.181 in resin pipe
(Note): For production before April 2015 : ø4.8 mm ø0.189 in
Front case : ABS, Rear case : ABS, LED display : Acrylic, Pressure port : PA
0.18 mm2 4-core oil resistant cabtyre cable, 2 m 6.562 ft long
Extension up to total 100 m 328.084 ft (less than 10 m 32.808 ft when conforming to CE marking) is possible with 0.3 mm2, or more, cable.
Net weight : 75 g approx., Gross weight : 135 g approx
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
EMC Directive, RoHS Directive
Differential pressure
0 to 2.00 kPa.D {0 to 204 mmH2O.D}
0 to 2.00 kPa.D {0 to 204 mmH2O.D}
0.01 kPa.D {1 mmH2O.D}
6 kPa.D {612 mmH2O.D}
Non-corrosive gas
kPa, mmH2O
12 to 24 V DC +10/-15% Ripple P-P 10 % or less
50 mA or less
NPN open-collector transistor
・Maximum sink current : 100 mA
・Applied voltage : 30 V DC or less (between comparative output and 0 V)
・Residual voltage : 1 V or less (at 100 mA sink current)
0.4 V or less (at 16 mA sink current)
DC-12 or DC-13
Selectable either normally open (NO) or normally closed (NC) by the key
0.01 kPa.D {1 mmH2O.D}
Within ±1 % F.S.
10 ms or less
Incorporated
-
3 digit red LED display (Sampling rate : 4 times/sec. approx.)
-0.05 to 2.10 kPa.D {-5 to 210 mmH2O.D}
Orange LED (lights up when the comparative output is ON)
Red LED (The indicator corresponding to the selected unit lights up during the sensing mode.)
Red LED (blinks in the M1 setting mode)
Red LED (blinks in the M2 setting mode)
3 (Industrial environment)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed),
Storage: -10 to +60 ℃ +14 to +140 ℉
35 to 85 % RH, Storage : 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Over ambient temperature range 0 to +50 ℃ +32 to +122 ℉
: within ±3 % F.S. of detected pressure at +25 ℃ +77 ℉
ø4.6 mm ø0.181 in resin pipe
(Note): For production before April 2015 : ø4.8 mm ø0.189 in
Front case : ABS, Rear case : ABS, LED display : Acrylic, Pressure port : PA
0.18 mm2 3-core oil resistant cabtyre cable, 2 m 6.562 ft long
Extension up to total 100 m 328.084 ft (less than 10 m 32.808 ft when conforming to CE marking) is possible with 0.3 mm2, or more, cable.
Net weight : 75 g approx., Gross weight : 135 g approx
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.