| | EMC Directive, RoHS Directive | Gauge pressure | DPH-101□(Compound pressure): -100.0 to +100.0 kPa,
DPH-102□(Positive pressure): 0 to +1.000 MPa,
DPH-103□(Vacuum pressure): 0 to -101.0 kPa
(Note) : It changes automatically according to the connected pressure sensor head. | DPH-101□(Compound pressure) : -199.9 to +199.9 kPa (-1.999 to +1.999 kgf/cm2, -19.98 to +19.98 psi, -1.999 to +1.999 bar, -1510 to +1537 mmHg, -59.4 to +60.5 inHg)
DPH-102□(Positive pressure) : -1.050 to +1.050 MPa (-10.71 to +10.71 kgf/cm2, -152.2 to +152.2 psi, -10.50 to +10.50 bar)
DPH-103□(Vacuum pressure) : +101.3 to -101.3 kPa (+1.033 to -1.033 kgf/cm2, +14.70 to -14.70 psi, +1.013 to -1.013 bar, +760 to -760 mmHg, +29.9 to -29.9 inHg)
(Note) : It changes automatically according to the connected pressure sensor head. | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less | Normal operation : 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage) ECO mode (STD) : 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage) ECO mode (FULL) : 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage) Excluding the current consumption of sensor head and analog output current | Same as supply voltage | NPN open-collector transistor (2 outputs) ・Maximum sink current : 100 mA ・Applied voltage : 30 V DC or less (between comparative output and 0 V) ・Residual voltage : 2 V or less (at 100 mA sink current) | NO / NC, selectable by key operation | EASY mode / Hysteresis mode / Window comparator mode | Minimum 1 digit (variable)(however, 2 digits when using psi unit) | With vacuum / positive pressure type connected : within ±0.2 % F.S. (±2 digits) With compound pressure type connected : within ±0.2 % F.S. (±4 digits) | 0.5 ms, 1 ms, 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation | Incorporated | ・Output current : 1 to 5 V DC ・Zero point : within 1 V ± 0.5 % F.S. (vacuum / positive pressure type) within 3 V ± 0.5 % F.S. (compound pressure type) ・Span : within 4 V ± 0.5 % F.S. ・Linearity : within ±0.1 % F.S. ・Output impedance : 1 kΩ approx.
・Output current : 4 to 20 mA ・Zero point : within 4 mA ± 1 % F.S. (vacuum / positive pressure type) within 12 mA ± 1.5 % F.S. (compound pressure type) ・Span : within 16 mA ± 1.5 % F.S. ・Linearity : within ±0.1 % F.S. ・Load resistance : 250 Ω (max.).
| Input voltage range : 1 to 5 V DC (over rated pressure range) | ON voltage : +0.4 V DC or less OFF voltage : +5 to +30 V DC, or open Input impedance : 10 kΩ approx. Input time : 1 ms or more | 4 digits + 4 digits 3-color LCD display (Display refresh rate : 250 ms, 500 ms, 1,000 ms, selectable by key operation) | Vacuum pressure : +5.1 to -101.3 kPa, Positive pressure : -0.050 to +1.020 MPa, Compound pressure : -101.3 to +105.0 kPa | Orange LED (Comparative output 1 operation indicator, comparative output 2 operation indicator : Lights up when each comparative output is ON) | IP40 (IEC) | -10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage : -10 to +60 ℃ +14 to +140 ℉ | 35 to 85 % RH, Storage : 35 to 85 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, double amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each (when panel mounting bracket is mounted : 10 to 150 Hz frequency, double amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each) | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | Within ±0.5 % F.S. (ambient temperature range based on +20 ℃ +68 ℉) | Enclosure : PBT (glass fiber reinforced), LCD display : Acrylic, Mounting threaded part : Brass (nickel plated), Switch part : Silicone rubber | Connector | Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | Net weight : 25 g approx. (excluding connector attached cable), Gross weight : 140 g approx. | Pressure unit label : 1 set | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. The values specified above are applied only to the controller. |
| | EMC Directive, RoHS Directive | Gauge pressure | DPH-101□(Compound pressure): -100.0 to +100.0 kPa,
DPH-102□(Positive pressure): 0 to +1.000 MPa,
DPH-103□(Vacuum pressure): 0 to -101.0 kPa
(Note) : It changes automatically according to the connected pressure sensor head. | DPH-101□(Compound pressure) : -199.9 to +199.9 kPa (-1.999 to +1.999 kgf/cm2, -19.98 to +19.98 psi, -1.999 to +1.999 bar, -1510 to +1537 mmHg, -59.4 to +60.5 inHg)
DPH-102□(Positive pressure) : -1.050 to +1.050 MPa (-10.71 to +10.71 kgf/cm2, -152.2 to +152.2 psi, -10.50 to +10.50 bar)
DPH-103□(Vacuum pressure) : +101.3 to -101.3 kPa (+1.033 to -1.033 kgf/cm2, +14.70 to -14.70 psi, +1.013 to -1.013 bar, +760 to -760 mmHg, +29.9 to -29.9 inHg)
(Note) : It changes automatically according to the connected pressure sensor head. | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less | Normal operation : 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage) ECO mode (STD) : 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage) ECO mode (FULL) : 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage) Excluding the current consumption of sensor head and analog output current | Same as supply voltage | PNP open-collector transistor (2 outputs) ・Maximum source current : 100 mA ・Applied voltage : 30 V DC or less (between comparative output and +V) ・Residual voltage : 2 V or less (at 100 mA source current) | NO / NC, selectable by key operation | EASY mode / Hysteresis mode / Window comparator mode | Minimum 1 digit (variable)(however, 2 digits when using psi unit) | With vacuum / positive pressure type connected : within ±0.2 % F.S. (±2 digits) With compound pressure type connected : within ±0.2 % F.S. (±4 digits) | 0.5 ms, 1 ms, 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation | Incorporated | ・Output current : 1 to 5 V DC ・Zero point : within 1 V ± 0.5 % F.S. (vacuum / positive pressure type) within 3 V ± 0.5 % F.S. (compound pressure type) ・Span : within 4 V ± 0.5 % F.S. ・Linearity : within ±0.1 % F.S. ・Output impedance : 1 kΩ approx.
・Output current : 4 to 20 mA ・Zero point : within 4 mA ± 1 % F.S. (vacuum / positive pressure type) within 12 mA ± 1.5 % F.S. (compound pressure type) ・Span : within 16 mA ± 1.5 % F.S. ・Linearity : within ±0.1 % F.S. ・Load resistance : 250 Ω (max.).
| Input voltage range : 1 to 5 V DC (over rated pressure range) | ON voltage : +5 V to +V DC OFF voltage : +0.6 V DC or less, or open Input impedance : 10 kΩ approx. Input time : 1 ms or more | 4 digits + 4 digits 3-color LCD display (Display refresh rate : 250 ms, 500 ms, 1,000 ms, selectable by key operation) | Vacuum pressure : +5.1 to -101.3 kPa, Positive pressure : -0.050 to +1.020 MPa, Compound pressure : -101.3 to +105.0 kPa | Orange LED (Comparative output 1 operation indicator, comparative output 2 operation indicator : Lights up when each comparative output is ON) | IP40 (IEC) | -10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage : -10 to +60 ℃ +14 to +140 ℉ | 35 to 85 % RH, Storage : 35 to 85 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, double amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each (when panel mounting bracket is mounted : 10 to 150 Hz frequency, double amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each) | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | Within ±0.5 % F.S. (ambient temperature range based on +20 ℃ +68 ℉) | Enclosure : PBT (glass fiber reinforced), LCD display : Acrylic, Mounting threaded part : Brass (nickel plated), Switch part : Silicone rubber | Connector | Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | Net weight : 25 g approx. (excluding connector attached cable), Gross weight : 140 g approx. | Pressure unit label : 1 set | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. The values specified above are applied only to the controller. |
| | EMC Directive, RoHS Directive | Gauge pressure | DPH-101□(Compound pressure): -100.0 to +100.0 kPa,
DPH-102□(Positive pressure): 0 to +1.000 MPa,
DPH-103□(Vacuum pressure): 0 to -101.0 kPa
(Note) : It changes automatically according to the connected pressure sensor head. | DPH-101□(Compound pressure) : -199.9 to +199.9 kPa (-1.999 to +1.999 kgf/cm2, -19.98 to +19.98 psi, -1.999 to +1.999 bar, -1510 to +1537 mmHg, -59.4 to +60.5 inHg)
DPH-102□(Positive pressure) : -1.050 to +1.050 MPa (-10.71 to +10.71 kgf/cm2, -152.2 to +152.2 psi, -10.50 to +10.50 bar)
DPH-103□(Vacuum pressure) : +101.3 to -101.3 kPa (+1.033 to -1.033 kgf/cm2, +14.70 to -14.70 psi, +1.013 to -1.013 bar, +760 to -760 mmHg, +29.9 to -29.9 inHg)
(Note) : It changes automatically according to the connected pressure sensor head. | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less | Normal operation : 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage) ECO mode (STD) : 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage) ECO mode (FULL) : 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage) Excluding the current consumption of sensor head and analog output current | Same as supply voltage | PNP open-collector transistor (2 outputs) ・Maximum source current : 100 mA ・Applied voltage : 30 V DC or less (between comparative output and +V) ・Residual voltage : 2 V or less (at 100 mA source current) | NO / NC, selectable by key operation | EASY mode / Hysteresis mode / Window comparator mode | Minimum 1 digit (variable)(however, 2 digits when using psi unit) | With vacuum / positive pressure type connected : within ±0.2 % F.S. (±2 digits) With compound pressure type connected : within ±0.2 % F.S. (±4 digits) | 0.5 ms, 1 ms, 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation | Incorporated | ・Output current : 1 to 5 V DC ・Zero point : within 1 V ± 0.5 % F.S. (vacuum / positive pressure type) within 3 V ± 0.5 % F.S. (compound pressure type) ・Span : within 4 V ± 0.5 % F.S. ・Linearity : within ±0.1 % F.S. ・Output impedance : 1 kΩ approx.
・Output current : 4 to 20 mA ・Zero point : within 4 mA ± 1 % F.S. (vacuum / positive pressure type) within 12 mA ± 1.5 % F.S. (compound pressure type) ・Span : within 16 mA ± 1.5 % F.S. ・Linearity : within ±0.1 % F.S. ・Load resistance : 250 Ω (max.).
| Input voltage range : 1 to 5 V DC (over rated pressure range) | ON voltage : +5 V to +V DC OFF voltage : +0.6 V DC or less, or open Input impedance : 10 kΩ approx. Input time : 1 ms or more | 4 digits + 4 digits 3-color LCD display (Display refresh rate : 250 ms, 500 ms, 1,000 ms, selectable by key operation) | Vacuum pressure : +5.1 to -101.3 kPa, Positive pressure : -0.050 to +1.020 MPa, Compound pressure : -101.3 to +105.0 kPa | Orange LED (Comparative output 1 operation indicator, comparative output 2 operation indicator : Lights up when each comparative output is ON) | IP40 (IEC) | -10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage : -10 to +60 ℃ +14 to +140 ℉ | 35 to 85 % RH, Storage : 35 to 85 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, double amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each (when panel mounting bracket is mounted : 10 to 150 Hz frequency, double amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each) | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | Within ±0.5 % F.S. (ambient temperature range based on +20 ℃ +68 ℉) | Enclosure : PBT (glass fiber reinforced), LCD display : Acrylic, Mounting threaded part : Brass (nickel plated), Switch part : Silicone rubber | Connector | Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | Net weight : 25 g approx. (excluding connector attached cable), Gross weight : 140 g approx. | CN-66A-C2 (Connector attached cable 2 m 6.562 ft), Pressure unit label : 1 set | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. The values specified above are applied only to the controller. |
| | EMC Directive, RoHS Directive | Gauge pressure | DPH-101□(Compound pressure): -100.0 to +100.0 kPa,
DPH-102□(Positive pressure): 0 to +1.000 MPa,
DPH-103□(Vacuum pressure): 0 to -101.0 kPa
(Note) : It changes automatically according to the connected pressure sensor head. | DPH-101□(Compound pressure) : -199.9 to +199.9 kPa (-1.999 to +1.999 kgf/cm2, -19.98 to +19.98 psi, -1.999 to +1.999 bar, -1510 to +1537 mmHg, -59.4 to +60.5 inHg)
DPH-102□(Positive pressure) : -1.050 to +1.050 MPa (-10.71 to +10.71 kgf/cm2, -152.2 to +152.2 psi, -10.50 to +10.50 bar)
DPH-103□(Vacuum pressure) : +101.3 to -101.3 kPa (+1.033 to -1.033 kgf/cm2, +14.70 to -14.70 psi, +1.013 to -1.013 bar, +760 to -760 mmHg, +29.9 to -29.9 inHg)
(Note) : It changes automatically according to the connected pressure sensor head. | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less | Normal operation : 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage) ECO mode (STD) : 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage) ECO mode (FULL) : 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage) Excluding the current consumption of sensor head and analog output current | Same as supply voltage | NPN open-collector transistor (2 outputs) ・Maximum sink current : 100 mA ・Applied voltage : 30 V DC or less (between comparative output and 0 V) ・Residual voltage : 2 V or less (at 100 mA sink current) | NO / NC, selectable by key operation | EASY mode / Hysteresis mode / Window comparator mode | Minimum 1 digit (variable)(however, 2 digits when using psi unit) | With vacuum / positive pressure type connected : within ±0.2 % F.S. (±2 digits) With compound pressure type connected : within ±0.2 % F.S. (±4 digits) | 0.5 ms, 1 ms, 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation | Incorporated | ・Output current : 1 to 5 V DC ・Zero point : within 1 V ± 0.5 % F.S. (vacuum / positive pressure type) within 3 V ± 0.5 % F.S. (compound pressure type) ・Span : within 4 V ± 0.5 % F.S. ・Linearity : within ±0.1 % F.S. ・Output impedance : 1 kΩ approx.
・Output current : 4 to 20 mA ・Zero point : within 4 mA ± 1 % F.S. (vacuum / positive pressure type) within 12 mA ± 1.5 % F.S. (compound pressure type) ・Span : within 16 mA ± 1.5 % F.S. ・Linearity : within ±0.1 % F.S. ・Load resistance : 250 Ω (max.).
| Input voltage range : 1 to 5 V DC (over rated pressure range) | ON voltage : +0.4 V DC or less OFF voltage : +5 to +30 V DC, or open Input impedance : 10 kΩ approx. Input time : 1 ms or more | 4 digits + 4 digits 3-color LCD display (Display refresh rate : 250 ms, 500 ms, 1,000 ms, selectable by key operation) | Vacuum pressure : +5.1 to -101.3 kPa, Positive pressure : -0.050 to +1.020 MPa, Compound pressure : -101.3 to +105.0 kPa | Orange LED (Comparative output 1 operation indicator, comparative output 2 operation indicator : Lights up when each comparative output is ON) | IP40 (IEC) | -10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage : -10 to +60 ℃ +14 to +140 ℉ | 35 to 85 % RH, Storage : 35 to 85 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, double amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each (when panel mounting bracket is mounted : 10 to 150 Hz frequency, double amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each) | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | Within ±0.5 % F.S. (ambient temperature range based on +20 ℃ +68 ℉) | Enclosure : PBT (glass fiber reinforced), LCD display : Acrylic, Mounting threaded part : Brass (nickel plated), Switch part : Silicone rubber | Connector | Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | Net weight : 25 g approx. (excluding connector attached cable), Gross weight : 140 g approx. | CN-66A-C2 (Connector attached cable 2 m 6.562 ft), Pressure unit label : 1 set | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. The values specified above are applied only to the controller. |