Head-separated Dual Display Digital Pressure Sensor [For Gas] DPS-400 / DPH-100

The DPS-400 Pressure Sensors were designed to meet the specific requirements needed at today's production sites such as miniaturization of Sensors to facilitate the downsizing of equipment, convenient shape to better fit into their machines and efficient set-up functions that can help reduce the man-hours spent on replacements.

Part Number List

Results 2
Models table for series Head-separated Dual Display Digital Pressure Sensor [For Gas] DPS-400 / DPH-100
Part No.DatasheetCE Marking Directive ComplianceApplicable Sensor HeadRated Pressure Range Display/Set Pressure RangeSupply Voltage Power ConsumptionSensor Head Supply Voltage Sensor Head Input Comparative OutputComparative Output: Output OperationComparative Output: HysteresisComparative Output: RepeatabilityComparative Output: Response TimeAmbient TemperatureAmbient HumidityTemperature Characteristics MaterialWeight (Typ.)Remark
EMC Directive, RoHS Directive
Positive pressure : DPH-102□
Positive pressure : 0 to +1.000MPa
Positive pressure : -1.050 to +1.050 MPa
12 to 24 V DC ±10 % Ripple P-P 10 % or less
Normal operation : 650 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
ECO mode : 500 mW or less (Current consumption 20 mA or less at 24 V supply voltage)
(Note): Excluding current consumption of the applicable pressure sensor head.
Same as supply voltage
Input voltage range : 1 to 5 V DC (over rated pressure range)
NPN open-collector transistor
・Maximum sink current : 50 mA (Note 1)
・Applied voltage : 30 V DC or less (between comparative output and 0 V)
・Residual voltage : 1.5 V or less (Note 2) [at 50 mA (Note 1) sink current]
(Note 1): 25 mA max. if 5 or more controllers are connected together.
(Note 2): In case of using the quick-connection cable (cable length : 5 m 16.404 ft)(optional)
NO / NC, selectable by jog switch
Minimum 0 digit, variable by hysteresis setting
With compound pressure type connected : within ±0.2 % F.S. (±4 digits), With vacuum / positive pressure type connected : within ±0.2 % F.S. (±2 digits)
150 μs, 500 μs, 1 ms, 5 ms, 10 ms, 50 ms, 100 ms, 500 ms, selectable by jog switch
-10 to +50℃ +14 to +122℉ (cascading 8 to 16 controllers : -10 to +45℃ +14 to +133℉)(No dew condensation or icing allowed), Storage : -20 to +70℃ -4 to +158℉
35 to 85 % RH, Storage : 35 to 85 % RH
Over ambient temperature range -10 to +50℃ +14 to +122℉ : within ±0.5 % F.S. of pressure at +25℃ +77℉
Enclosure : Heat-resistant ABS, Protective cover : Polycarbonate, Jog switch : ABS, MODE key : Acrylic
Net weight : 20 g approx.
・Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20℃ +68℉.
・The cable for controller connection is not supplied as an accessory. Make sure to use the quick-connection cables (optional) given below.
Main cable (4-core) : CN-74-C1 (cable length : 1m 3.281 ft), CN-74-C2 (cable length : 2 m 6.562 ft), CN-74-C5 (cable length : 5 m 16.404 ft)
Sub cable (2-core) : CN-72-C1 (cable length : 1m 3.281 ft), CN-72-C2 (cable length : 2 m 6.562 ft), CN-72-C5 (cable length : 5 m 16.404 ft)
・The values specified above are applied only to the controller.
EMC Directive, RoHS Directive
Compound pressure : DPH-101□
Vacuum pressure : DPH-103□
Compound pressure : -100.0 to +100.0kPa
Vacuum pressure : 0 to -101kPa
Compound pressure : -199.9 to +199.9 kPa
Vacuum pressure : +101.3 to -101.3 kPa
12 to 24 V DC ±10 % Ripple P-P 10 % or less
Normal operation : 650 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
ECO mode : 500 mW or less (Current consumption 20 mA or less at 24 V supply voltage)
(Note): Excluding current consumption of the applicable pressure sensor head.
Same as supply voltage
Input voltage range : 1 to 5 V DC (over rated pressure range)
NPN open-collector transistor
・Maximum sink current : 50 mA (Note 1)
・Applied voltage : 30 V DC or less (between comparative output and 0 V)
・Residual voltage : 1.5 V or less (Note 2) [at 50 mA (Note 1) sink current]
(Note 1): 25 mA max. if 5 or more controllers are connected together.
(Note 2): In case of using the quick-connection cable (cable length : 5 m 16.404 ft)(optional)
NO / NC, selectable by jog switch
Minimum 0 digit, variable by hysteresis setting
With compound pressure type connected : within ±0.2 % F.S. (±4 digits), With vacuum / positive pressure type connected : within ±0.2 % F.S. (±2 digits)
150 μs, 500 μs, 1 ms, 5 ms, 10 ms, 50 ms, 100 ms, 500 ms, selectable by jog switch
-10 to +50℃ +14 to +122℉ (cascading 8 to 16 controllers : -10 to +45℃ +14 to +133℉)(No dew condensation or icing allowed), Storage : -20 to +70℃ -4 to +158℉
35 to 85 % RH, Storage : 35 to 85 % RH
Over ambient temperature range -10 to +50℃ +14 to +122℉ : within ±0.5 % F.S. of pressure at +25℃ +77℉
Enclosure : Heat-resistant ABS, Protective cover : Polycarbonate, Jog switch : ABS, MODE key : Acrylic
Net weight : 20 g approx.
・Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20℃ +68℉.
・The cable for controller connection is not supplied as an accessory. Make sure to use the quick-connection cables (optional) given below.
Main cable (4-core) : CN-74-C1 (cable length : 1m 3.281 ft), CN-74-C2 (cable length : 2 m 6.562 ft), CN-74-C5 (cable length : 5 m 16.404 ft)
Sub cable (2-core) : CN-72-C1 (cable length : 1m 3.281 ft), CN-72-C2 (cable length : 2 m 6.562 ft), CN-72-C5 (cable length : 5 m 16.404 ft)
・The values specified above are applied only to the controller.