| | EMC Directive, RoHS Directive | 100 mm 3.937 in | 0.1 to 1.2 m 0.328 to 3.937 ft (0.05 to 0.5 m 0.164 to 1.640 ft when set to SHORT)(Note) The sensing range is the possible setting distance between the emitter and the receiver. | 25 mm 0.984 in | 5 beam channels | ø35 mm ø1.378 in or more opaque object (completely beam interrupted object) | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 0.5 W or less Receiver: 0.8 W or less (Note) Obtain the current consumption by the following equation. Current consumption = Power consumption / Supply voltage (e.g.) When the supply voltage is 12 V, the current consumption of the emitter is 0.5 W / 12 V ≈ 0.042 A = 42 mA | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) | DC-12 or DC-13 | ON or OFF when one or more beam channels are interrupted / ON or OFF when two or more beam channels are interrupted, selectable by operation mode switch | Incorporated | 10 ms or less (when the interference prevention is used, in Light state: 30 ms or less, in Dark state: 13 ms or less) | Power indicator: Green LED (lights up when the power is ON) Job indicator: Orange LED (lights up or blinks when the job indicator input is Low, lighting pattern is selected by operation mode switch) | Operation indicator: Red LED (lights up when one or more beam channels are interrupted, but lights up when two beam channels or more are interrupted in the double-beaminterruption mode) Stable incident beam indicator: Green LED (lights up when all beam channels are stably received) Job indicator: Orange LED (lights up or blinks when the job indicator input is Low, lighting pattern is selected by operation mode switch) | Incorporated | 3 (Industrial environment) | IP62 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 490 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, synchronized scanning system) | Enclosure: Heat-resistant ABS Lens cover: Acrylic Indicator cover: Acrylic | 0.3 mm2 4-core (emitter: 3-core) oil resistant cabtyre cable, 2 m 6.562 ft long | Extension up to total 100 m 328.084 ft is possible for both emitter and receiver with 0.3 mm2, or more, cable. | Net weight: Emitter 80 g approx., Receiver 85 g approx. Gross weight: 270 g approx. |
| | EMC Directive, RoHS Directive | 100 mm 3.937 in | 0.2 to 3 m 0.656 to 9.843 ft (0.05 to 1 m 0.164 to 3.281 ft when set to SHORT) (Note) The sensing range is the possible setting distance between the emitter and the receiver. | 25 mm 0.984 in | 5 beam channels | ø35 mm ø1.378 in or more opaque object (completely beam interrupted object) | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 0.6 W or less Receiver: 0.9 W or less (Note) Obtain the current consumption by the following equation. Current consumption = Power consumption / Supply voltage (e.g.) When the supply voltage is 12 V, the current consumption of the emitter is 0.5 W / 12 V ≈ 0.042 A = 42 mA | PNP open-collector transistor - Maximum source current: 100 mA - Applied voltage: 30 V DC or less (between output and +V) - Residual voltage: 1 V or less (at 100 mA source current), 0.4 V or less (at 16 mA source current) | DC-12 or DC-13 | ON or OFF when one or more beam channels are interrupted / ON or OFF when two or more beam channels are interrupted, selectable by operation mode switch | Incorporated | 10 ms or less (when the interference prevention is used, in Light state: 30 ms or less, in Dark state: 13 ms or less) | Power indicator: Green LED (lights up when the power is ON) Job indicator: Orange LED (lights up or blinks when the job indicator input is High, lighting pattern is selected by operation mode switch) | Operation indicator: Red LED (lights up when one or more beam channels are interrupted, but lights up when two beam channels or more are interrupted in the double-beaminterruption mode) Stable incident beam indicator: Green LED (lights up when all beam channels are stably received) Job indicator: Orange LED (lights up or blinks when the job indicator input is High, lighting pattern is selected by operation mode switch) | Incorporated | 3 (Industrial environment) | IP62 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 490 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, synchronized scanning system) | Enclosure: Heat-resistant ABS Lens cover: Acrylic Indicator cover: Acrylic | 0.3 mm2 4-core (emitter: 3-core) oil resistant cabtyre cable, 2 m 6.562 ft long | Extension up to total 100 m 328.084 ft is possible for both emitter and receiver with 0.3 mm2, or more, cable. | |
| | EMC Directive, RoHS Directive | 100 mm 3.937 in | 0.2 to 3 m 0.656 to 9.843 ft (0.05 to 1 m 0.164 to 3.281 ft when set to SHORT) (Note) The sensing range is the possible setting distance between the emitter and the receiver. | 25 mm 0.984 in | 5 beam channels | ø35 mm ø1.378 in or more opaque object (completely beam interrupted object) | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 0.6 W or less Receiver: 0.9 W or less (Note) Obtain the current consumption by the following equation. Current consumption = Power consumption / Supply voltage (e.g.) When the supply voltage is 12 V, the current consumption of the emitter is 0.5 W / 12 V ≈ 0.042 A = 42 mA | PNP open-collector transistor - Maximum source current: 100 mA - Applied voltage: 30 V DC or less (between output and +V) - Residual voltage: 1 V or less (at 100 mA source current), 0.4 V or less (at 16 mA source current) | DC-12 or DC-13 | ON or OFF when one or more beam channels are interrupted / ON or OFF when two or more beam channels are interrupted, selectable by operation mode switch | Incorporated | 10 ms or less (when the interference prevention is used, in Light state: 30 ms or less, in Dark state: 13 ms or less) | Power indicator: Green LED (lights up when the power is ON) Job indicator: Orange LED (lights up or blinks when the job indicator input is High, lighting pattern is selected by operation mode switch) | Operation indicator: Red LED (lights up when one or more beam channels are interrupted, but lights up when two beam channels or more are interrupted in the double-beaminterruption mode) Stable incident beam indicator: Green LED (lights up when all beam channels are stably received) Job indicator: Orange LED (lights up or blinks when the job indicator input is High, lighting pattern is selected by operation mode switch) | Incorporated | 3 (Industrial environment) | IP62 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 490 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, synchronized scanning system) | Enclosure: Heat-resistant ABS Lens cover: Acrylic Indicator cover: Acrylic | 0.3 mm2 4-core (emitter: 3-core) oil resistant cabtyre cable, 2 m 6.562 ft long | Extension up to total 100 m 328.084 ft is possible for both emitter and receiver with 0.3 mm2, or more, cable. | Net weight: Emitter 70 g approx., Receiver 80 g approx. Gross weight: 270 g approx. |
| | EMC Directive, RoHS Directive | 100 mm 3.937 in | 0.1 to 1.2 m 0.328 to 3.937 ft (0.05 to 0.5 m 0.164 to 1.640 ft when set to SHORT) (Note) The sensing range is the possible setting distance between the emitter and the receiver. | 25 mm 0.984 in | 5 beam channels | ø35 mm ø1.378 in or more opaque object (completely beam interrupted object) | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 0.5 W or less Receiver: 0.8 W or less (Note) Obtain the current consumption by the following equation. Current consumption = Power consumption / Supply voltage (e.g.) When the supply voltage is 12 V, the current consumption of the emitter is 0.5 W / 12 V ≈ 0.042 A = 42 mA | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) | DC-12 or DC-13 | ON or OFF when one or more beam channels are interrupted / ON or OFF when two or more beam channels are interrupted, selectable by operation mode switch | Incorporated | 10 ms or less (when the interference prevention is used, in Light state: 30 ms or less, in Dark state: 13 ms or less) | Power indicator: Green LED (lights up when the power is ON) Job indicator: Orange LED (lights up or blinks when the job indicator input is Low, lighting pattern is selected by operation mode switch) | Operation indicator: Red LED (lights up when one or more beam channels are interrupted, but lights up when two beam channels or more are interrupted in the double-beaminterruption mode) Stable incident beam indicator: Green LED (lights up when all beam channels are stably received) Job indicator: Orange LED (lights up or blinks when the job indicator input is Low, lighting pattern is selected by operation mode switch) | Incorporated | 3 (Industrial environment) | IP62 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 490 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, synchronized scanning system) | Enclosure: Heat-resistant ABS Lens cover: Acrylic Indicator cover: Acrylic | 0.3 mm2 4-core (emitter: 3-core) oil resistant cabtyre cable, 2 m 6.562 ft long | Extension up to total 100 m 328.084 ft is possible for both emitter and receiver with 0.3 mm2, or more, cable. | |
| | EMC Directive, RoHS Directive | 100 mm 3.937 in | 0.2 to 3 m 0.656 to 9.843 ft (0.05 to 1 m 0.164 to 3.281 ft when set to SHORT) (Note) The sensing range is the possible setting distance between the emitter and the receiver. | 25 mm 0.984 in | 5 beam channels | ø35 mm ø1.378 in or more opaque object (completely beam interrupted object) | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 0.5 W or less Receiver: 0.8 W or less (Note) Obtain the current consumption by the following equation. Current consumption = Power consumption / Supply voltage (e.g.) When the supply voltage is 12 V, the current consumption of the emitter is 0.5 W / 12 V ≈ 0.042 A = 42 mA | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) | DC-12 or DC-13 | ON or OFF when one or more beam channels are interrupted / ON or OFF when two or more beam channels are interrupted, selectable by operation mode switch | Incorporated | 10 ms or less (when the interference prevention is used, in Light state: 30 ms or less, in Dark state: 13 ms or less) | Power indicator: Green LED (lights up when the power is ON) Job indicator: Orange LED (lights up or blinks when the job indicator input is Low, lighting pattern is selected by operation mode switch) | Operation indicator: Red LED (lights up when one or more beam channels are interrupted, but lights up when two beam channels or more are interrupted in the double-beaminterruption mode) Stable incident beam indicator: Green LED (lights up when all beam channels are stably received) Job indicator: Orange LED (lights up or blinks when the job indicator input is Low, lighting pattern is selected by operation mode switch) | Incorporated | 3 (Industrial environment) | IP62 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 490 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, synchronized scanning system) | Enclosure: Heat-resistant ABS Lens cover: Acrylic Indicator cover: Acrylic | 0.3 mm2 4-core (emitter: 3-core) oil resistant cabtyre cable, 2 m 6.562 ft long | Extension up to total 100 m 328.084 ft is possible for both emitter and receiver with 0.3 mm2, or more, cable. | |
| | EMC Directive, RoHS Directive | 100 mm 3.937 in | 0.2 to 3 m 0.656 to 9.843 ft (0.05 to 1 m 0.164 to 3.281 ft when set to SHORT) (Note) The sensing range is the possible setting distance between the emitter and the receiver. | 25 mm 0.984 in | 5 beam channels | ø35 mm ø1.378 in or more opaque object (completely beam interrupted object) | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 0.5 W or less Receiver: 0.8 W or less (Note) Obtain the current consumption by the following equation. Current consumption = Power consumption / Supply voltage (e.g.) When the supply voltage is 12 V, the current consumption of the emitter is 0.5 W / 12 V ≈ 0.042 A = 42 mA | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) | DC-12 or DC-13 | ON or OFF when one or more beam channels are interrupted / ON or OFF when two or more beam channels are interrupted, selectable by operation mode switch | Incorporated | 10 ms or less (when the interference prevention is used, in Light state: 30 ms or less, in Dark state: 13 ms or less) | Power indicator: Green LED (lights up when the power is ON) Job indicator: Orange LED (lights up or blinks when the job indicator input is Low, lighting pattern is selected by operation mode switch) | Operation indicator: Red LED (lights up when one or more beam channels are interrupted, but lights up when two beam channels or more are interrupted in the double-beaminterruption mode) Stable incident beam indicator: Green LED (lights up when all beam channels are stably received) Job indicator: Orange LED (lights up or blinks when the job indicator input is Low, lighting pattern is selected by operation mode switch) | Incorporated | 3 (Industrial environment) | IP62 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 490 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, synchronized scanning system) | Enclosure: Heat-resistant ABS Lens cover: Acrylic Indicator cover: Acrylic | 0.3 mm2 4-core (emitter: 3-core) oil resistant cabtyre cable, 2 m 6.562 ft long | Extension up to total 100 m 328.084 ft is possible for both emitter and receiver with 0.3 mm2, or more, cable. | Net weight: Emitter 70 g approx., Receiver 80 g approx. Gross weight: 270 g approx. |
| | EMC Directive, RoHS Directive | 100 mm 3.937 in | 0.1 to 1.2 m 0.328 to 3.937 ft (0.05 to 0.5 m 0.164 to 1.640 ft when set to SHORT) (Note) The sensing range is the possible setting distance between the emitter and the receiver. | 25 mm 0.984 in | 5 beam channels | ø35 mm ø1.378 in or more opaque object (completely beam interrupted object) | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 0.6 W or less Receiver: 0.9 W or less (Note) Obtain the current consumption by the following equation. Current consumption = Power consumption / Supply voltage (e.g.) When the supply voltage is 12 V, the current consumption of the emitter is 0.5 W / 12 V ≈ 0.042 A = 42 mA | PNP open-collector transistor - Maximum source current: 100 mA - Applied voltage: 30 V DC or less (between output and +V) - Residual voltage: 1 V or less (at 100 mA source current), 0.4 V or less (at 16 mA source current) | DC-12 or DC-13 | ON or OFF when one or more beam channels are interrupted / ON or OFF when two or more beam channels are interrupted, selectable by operation mode switch | Incorporated | 10 ms or less (when the interference prevention is used, in Light state: 30 ms or less, in Dark state: 13 ms or less) | Power indicator: Green LED (lights up when the power is ON) Job indicator: Orange LED (lights up or blinks when the job indicator input is High, lighting pattern is selected by operation mode switch) | Operation indicator: Red LED (lights up when one or more beam channels are interrupted, but lights up when two beam channels or more are interrupted in the double-beaminterruption mode) Stable incident beam indicator: Green LED (lights up when all beam channels are stably received) Job indicator: Orange LED (lights up or blinks when the job indicator input is High, lighting pattern is selected by operation mode switch) | Incorporated | 3 (Industrial environment) | IP62 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 490 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, synchronized scanning system) | Enclosure: Heat-resistant ABS Lens cover: Acrylic Indicator cover: Acrylic | 0.3 mm2 4-core (emitter: 3-core) oil resistant cabtyre cable, 2 m 6.562 ft long | Extension up to total 100 m 328.084 ft is possible for both emitter and receiver with 0.3 mm2, or more, cable. | Net weight: Emitter 80 g approx., Receiver 85 g approx. Gross weight: 270 g approx. |
| | EMC Directive, RoHS Directive | 100 mm 3.937 in | 0.2 to 3 m 0.656 to 9.843 ft (0.05 to 1 m 0.164 to 3.281 ft when set to SHORT) (Note) The sensing range is the possible setting distance between the emitter and the receiver. | 25 mm 0.984 in | 5 beam channels | ø35 mm ø1.378 in or more opaque object (completely beam interrupted object) | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 0.5 W or less Receiver: 0.8 W or less (Note) Obtain the current consumption by the following equation. Current consumption = Power consumption / Supply voltage (e.g.) When the supply voltage is 12 V, the current consumption of the emitter is 0.5 W / 12 V ≈ 0.042 A = 42 mA | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) | DC-12 or DC-13 | ON or OFF when one or more beam channels are interrupted / ON or OFF when two or more beam channels are interrupted, selectable by operation mode switch | Incorporated | 10 ms or less (when the interference prevention is used, in Light state: 30 ms or less, in Dark state: 13 ms or less) | Power indicator: Green LED (lights up when the power is ON) Job indicator: Orange LED (lights up or blinks when the job indicator input is Low, lighting pattern is selected by operation mode switch) | Operation indicator: Red LED (lights up when one or more beam channels are interrupted, but lights up when two beam channels or more are interrupted in the double-beaminterruption mode) Stable incident beam indicator: Green LED (lights up when all beam channels are stably received) Job indicator: Orange LED (lights up or blinks when the job indicator input is Low, lighting pattern is selected by operation mode switch) | Incorporated | 3 (Industrial environment) | IP62 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 490 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, synchronized scanning system) | Enclosure: Heat-resistant ABS Lens cover: Acrylic Indicator cover: Acrylic | 0.3 mm2 4-core (emitter: 3-core) oil resistant cabtyre cable, 2 m 6.562 ft long | Extension up to total 100 m 328.084 ft is possible for both emitter and receiver with 0.3 mm2, or more, cable. | |
| | EMC Directive, RoHS Directive | 100 mm 3.937 in | 0.1 to 1.2 m 0.328 to 3.937 ft (0.05 to 0.5 m 0.164 to 1.640 ft when set to SHORT) (Note) The sensing range is the possible setting distance between the emitter and the receiver. | 25 mm 0.984 in | 5 beam channels | ø35 mm ø1.378 in or more opaque object (completely beam interrupted object) | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 0.6 W or less Receiver: 0.9 W or less (Note) Obtain the current consumption by the following equation. Current consumption = Power consumption / Supply voltage (e.g.) When the supply voltage is 12 V, the current consumption of the emitter is 0.5 W / 12 V ≈ 0.042 A = 42 mA | PNP open-collector transistor - Maximum source current: 100 mA - Applied voltage: 30 V DC or less (between output and +V) - Residual voltage: 1 V or less (at 100 mA source current), 0.4 V or less (at 16 mA source current) | DC-12 or DC-13 | ON or OFF when one or more beam channels are interrupted / ON or OFF when two or more beam channels are interrupted, selectable by operation mode switch | Incorporated | 10 ms or less (when the interference prevention is used, in Light state: 30 ms or less, in Dark state: 13 ms or less) | Power indicator: Green LED (lights up when the power is ON) Job indicator: Orange LED (lights up or blinks when the job indicator input is High, lighting pattern is selected by operation mode switch) | Operation indicator: Red LED (lights up when one or more beam channels are interrupted, but lights up when two beam channels or more are interrupted in the double-beaminterruption mode) Stable incident beam indicator: Green LED (lights up when all beam channels are stably received) Job indicator: Orange LED (lights up or blinks when the job indicator input is High, lighting pattern is selected by operation mode switch) | Incorporated | 3 (Industrial environment) | IP62 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 490 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, synchronized scanning system) | Enclosure: Heat-resistant ABS Lens cover: Acrylic Indicator cover: Acrylic | 0.3 mm2 4-core (emitter: 3-core) oil resistant cabtyre cable, 2 m 6.562 ft long | Extension up to total 100 m 328.084 ft is possible for both emitter and receiver with 0.3 mm2, or more, cable. | |